Remanent magnetisation in multifilamentary Bi-2223 tapes with filament bridging

被引:6
|
作者
Kvitkovic, J [1 ]
Polak, M [1 ]
机构
[1] Slovak Acad Sci, Inst Elect Engn, SK-84239 Bratislava, Slovakia
来源
关键词
magnetic field profile; AC losses; Bi-2223; tape; Hall sensor;
D O I
10.1016/S0921-4534(02)00959-0
中图分类号
O59 [应用物理学];
学科分类号
摘要
One of the methods used for the separation of hysteresis and coupling losses in multifilamentary Bi-2223 tapes is based on the assumptions that hysteresis losses per unit length are independent of the sample length while coupling losses per unit length increase proportionally to the square of the sample length. We measured the remanent magnetic field of several multifilamentary Bi-2223 tape samples with different length using the I fall probe scanning technique, For most of the tapes, the remanent magnetic field, which is proportional to magnetisation. depended Oil the sample length. Only for a small number of tapes the sample length did not affect the remanent magnetisation. The observed behavior is attributed to the existence of filament bridging, (C) 2002 Elsevier Science B.V. All rights reserved,
引用
收藏
页码:1012 / 1015
页数:4
相关论文
共 50 条
  • [21] Optimal reduction in rolling Ag-sheathed Bi-2223 multifilamentary tapes
    Zeng, R.
    Beales, T.P.
    Liu, H.K.
    Dou, S.X.
    Superconductor Science and Technology, 1998, 11 (03): : 299 - 303
  • [22] Optimal reduction in rolling Ag-sheathed Bi-2223 multifilamentary tapes
    Zeng, R
    Beales, TP
    Liu, HK
    Dou, SX
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1998, 11 (03): : 299 - 303
  • [23] Development of Ag sheathed Bi-2223 multifilamentary tapes with MgO coated filaments
    Lennikov, V
    Caudevilla, H
    Angurel, LA
    de la Fuente, GF
    Navarro, R
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 2553 - 2556
  • [24] Transport ac losses in Bi-2223 multifilamentary tapes - conductor materials aspect
    Glowacki, BA
    Majoros, M
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2000, 13 (05): : 483 - 487
  • [25] Study of important factors affecting AC losses of multifilamentary Bi-2223 tapes
    Polak, M
    Krempasky, L
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2001, 357 (SUPPL. 1): : 1144 - 1152
  • [26] Numerical modelling of Bi-2223 multifilamentary tapes with position-dependent Jc
    Stavrev, S
    Grilli, F
    Dutoit, B
    Klutsch, I
    Vinot, E
    Tixador, P
    Gerard, M
    Skov-Hansen, P
    Hansen, JB
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2002, 372 (PART 3): : 1800 - 1805
  • [27] AC losses in multifilamentary Bi-2223/Ag tapes subjected to bending strains
    Suzuki, H
    Ogawa, J
    Ciszek, M
    Tsukamoto, O
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2005, 426 : 1333 - 1338
  • [28] Temperature dependence of transport AC losses in Bi-2223/Ag multifilamentary tapes
    Majoros, M
    Jansak, L
    Zannella, S
    Curcio, F
    La Cascia, P
    Ottoboni, V
    Friend, CM
    Le Lay, L
    Glowacki, BA
    Campbell, AM
    PHYSICA C, 1998, 310 (1-4): : 6 - 11
  • [29] Fabrication of Bi-2223 tapes
    Fischer, B
    Arndt, T
    Gierl, J
    Krauth, H
    Munz, M
    Szulczyk, A
    Leghissa, M
    Neumüller, HW
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 3261 - 3264
  • [30] Filament decoupling and magnetization loss of multifilamentary Bi2223 superconducting tapes
    Amemiya, N
    Tsukamoto, O
    Torii, M
    Ciszek, M
    Kawasaki, H
    Mizushima, E
    Ishii, S
    Ayai, N
    Hayashi, K
    Ueyama, M
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (01) : 1204 - 1207