Performance of the comet assay in a high-throughput version

被引:28
|
作者
Stang, A. [1 ]
Witte, I. [1 ]
机构
[1] Carl VonOssietzky Univ Oldenburg, IBU, D-26111 Oldenburg, Germany
关键词
Comet assay; High throughput; MCP; Multi-chamber plate; Adherent cells; IN-VITRO; GENETIC TOXICOLOGY; AUTOMATIC-ANALYSIS; MICRONUCLEUS TEST; ELECTROPHORESIS; DISCRIMINATE; FIBROBLASTS; GUIDELINES; SLIDES; CELLS;
D O I
10.1016/j.mrgentox.2009.01.007
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The high-throughput comet assay was developed to reduce the processing time and to increase sample-throughput of the assay as described by Tice et al. (RR. Tice. E. Agurell, D. Anderson, B. Burlinson, A. Hartmann, H. Kobayashi, Y. Miyamae, E. Rojas. JC. Ryu, YF. Sasaki. Single cell gel/comet assay: guidelines for in vitro and in vivo genetic toxicology testing, Environ. Mol. Mutagen.35 (2000) 206-221). This high-throughput version allows for the processing of up to 400 samples per day. The basis of the new assay is a 96-well plate (multichamber plate. MCP) suitable for electrophoresis. After exposure of the cells to genotoxic agents, the walls of the MCP are separated from the bottom plate. All 96 samples together then go through lysis, alkaline unwinding, electrophoresis, neutralization, and staining. In this Study, the first concentration-dependent results obtained with the high-through put version are shown and a comparison is made with the standard version of the comet assay using five representative chemicals with different genotoxic properties. These genotoxic chemicals are methyl methanesulfonate (MMS) and ethylnitrosourea. which form small alkylation adducts, 4-nitroquinoline-1-oxide for bulky adducts, cisplatin for DNA cross-links, and H2O2 for direct DNA breakage. For medium and high effective concentrations a standard deviation of 3-20% for three replicates(25 cornets per sample)was determined. A comparison of the standard assay with the high-throughput version revealed similar results for MMS and H2O2. The integrated viability assay (FDA assay), which was performed after chemical treatment and before detachment of the bottom from the walls of the MCP. did not influence the outcome of the comet formation. In Conclusion. the high-throughput version of the comet assay facilitates the determination of genotoxicity in cases where large numbers of samples have to be measured, Such as during testing of industrial chemicals, biomonitoring of enviromental samples, and early screening of drug candidates for genotoxicity/photogenotoxicity. For Such applications the cost- and time-saving of the high-throughput method provides substantial advantages over the standard comet assay. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:5 / 10
页数:6
相关论文
共 50 条
  • [21] Pitfalls in the desulphation of glucosinolates in a high-throughput assay
    Hennig, K.
    Verkerk, R.
    Bonnema, G.
    Dekker, M.
    FOOD CHEMISTRY, 2012, 134 (04) : 2355 - 2361
  • [22] High-throughput screening assay for helicase enzymes
    Tularik Inc., South San Francisco, CA 94080, United States
    Anal. Biochem., 1 (22-27):
  • [23] Transcription with a novel high-throughput microfluidic assay
    Kim, Soohong
    Streets, Aaron M.
    Lin, Ron R.
    Quake, Stephen R.
    Weiss, Shimon
    Majumdar, Devdoot S.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [24] A high-throughput screening assay for pyruvate carboxylase
    Wyatt, Brittney N.
    Arnold, Leggy A.
    Maurice, Martin St.
    ANALYTICAL BIOCHEMISTRY, 2018, 550 : 90 - 98
  • [25] A high-throughput assay of membrane protein stability
    Postis, Vincent L. G.
    Deacon, Sarah E.
    Roach, Peter C. J.
    Wright, Gareth S. A.
    Xia, Xiaoobing
    Ingram, Jean C.
    Hadden, Jonathan M.
    Henderson, Peter J. F.
    Phillips, Simon E. V.
    McPherson, Michael J.
    Baldwin, Stephen A.
    MOLECULAR MEMBRANE BIOLOGY, 2008, 25 (08) : 617 - 624
  • [26] Novel High-Throughput Deoxyribonuclease 1 Assay
    Jang, Dae Song
    Penthala, Narsimha R.
    Apostolov, Eugene O.
    Wang, Xiaoying
    Fahmi, Tariq
    Crooks, Peter A.
    Basnakian, Alexei G.
    JOURNAL OF BIOMOLECULAR SCREENING, 2015, 20 (02) : 202 - 211
  • [27] A high-throughput capillary assay for bacterial chemotaxis
    Bainer, R
    Park, H
    Cluzel, P
    JOURNAL OF MICROBIOLOGICAL METHODS, 2003, 55 (01) : 315 - 319
  • [28] High-throughput zebrafish intramuscular recording assay
    Cho, Sung-Joon
    Kang, Yang Jun
    Kim, Sohee
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 304
  • [29] Performance evaluation of the high-throughput quantitative Alinity m BK virus assay
    Hirschhorn, Julie W.
    Sasaki, Mark M.
    Kegl, April
    Akter, Tanjina
    Dickerson, Tanisha
    Narlieva, Momka
    Nhan, Nhi
    Liu, Tianxi
    Jim, Patricia
    Young, Stephen
    Orner, Erika
    Thwe, Phyu
    Lucic, Danijela
    Goldstein, D. Yitzchak
    JOURNAL OF CLINICAL MICROBIOLOGY, 2024, 62 (04)
  • [30] Partnership for high-throughput assay development and validation
    Potticary, James
    BIOANALYSIS, 2013, 5 (12) : 1472 - 1472