Optimization of X-ray microplanar beam radiation therapy for deep-seated tumors by a simulation study

被引:10
|
作者
Shinohara, Kunio [1 ]
Kondoh, Takeshi [2 ,3 ]
Nariyama, Nobuteru [4 ]
Fujita, Hajime [1 ]
Washio, Masakazu [1 ]
Aoki, Yukimasa [5 ]
机构
[1] Waseda Univ, Res Inst Sci & Engn, Shinjuku Ku, Tokyo 1698555, Japan
[2] Kobe Univ, Grad Sch Med, Dept Neurosurg, Kobe, Hyogo 657, Japan
[3] Shinsuma Gen Hosp, Kobe, Hyogo, Japan
[4] Japan Synchrotron Radiat Res Inst, Kobe, Hyogo, Japan
[5] Med Corp YUKOUKAI Clin, Funabashi, Chiba, Japan
基金
日本学术振兴会;
关键词
Microbeam radiation therapy; X-rays; Monte Carlo simulation; transverse dose distribution; energy dependence; IN-VIVO; 9L GLIOSARCOMA; MICROBEAM; SYNCHROTRON; BRAIN; IRRADIATION; PALLIATION; TOLERANCE; EFFICACY; TISSUES;
D O I
10.3233/XST-140434
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A Monte Carlo simulation was applied to study the energy dependence on the transverse dose distribution of microplanar beam radiation therapy (MRT) for deep-seated tumors. The distribution was found to be the peak (in-beam) dose and the decay from the edge of the beam down to the valley. The area below the same valley dose level (valley region) was decreased with the increase in the energy of X-rays at the same beam separation. To optimize the MRT, we made the following two assumptions: the therapeutic gain may be attributed to the efficient recovery of normal tissue caused by the beam separation; and a key factor for the efficient recovery of normal tissue depends on the area size of the valley region. Based on these assumptions and the results of the simulated dose distribution, we concluded that the optimum X-ray energy was in the range of 100-300 keV depending on the effective peak dose to the target tumors and/or tolerable surface dose. In addition, we proposed parameters to be studied for the optimization of MRT to deep-seated tumors.
引用
收藏
页码:395 / 406
页数:12
相关论文
共 50 条
  • [31] X-RAY THERAPY FOR RADIATION
    GLADSTEIN, AH
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1980, 75 (04) : 371 - 371
  • [32] Deep x-ray therapy
    Morton, Reginald
    AMERICAN JOURNAL OF ROENTGENOLOGY AND RADIUM THERAPY, 1923, 10 : 119 - 125
  • [33] Laser interstitial thermal therapy for deep-seated perivascular brain tumors is not associated with distal ischemia
    Jared C. Reese
    Hassan A. Fadel
    Jacob A. Pawloski
    Mariam Samir
    Sameah Haider
    Ricardo J. Komatar
    Evan Luther
    Alexis A. Morell
    Mike E. Ivan
    Adam M. Robin
    Steven N. Kalkanis
    Ian Y. Lee
    Journal of Neuro-Oncology, 2024, 166 : 265 - 272
  • [34] Ultrasound-Assisted Photothermal Therapy (ULTRA-PTT) for the Treatment of Deep-Seated Tumors
    Kim, Haemin
    Kim, Jinwoo
    Seo, An Na
    Chang, Jin Ho
    ADVANCED OPTICAL MATERIALS, 2024, 12 (20):
  • [35] TREATMENT OF DEEP-SEATED MALIGNANT TUMORS WITH MULTIPLE-PORT TECHNIC SIMULATING ROTATION THERAPY
    KAPLAN, II
    ETKIN, SI
    RADIOLOGY, 1948, 51 (02) : 188 - 204
  • [36] Laser interstitial thermal therapy for deep-seated perivascular brain tumors is not associated with distal ischemia
    Reese, Jared C.
    Fadel, Hassan A.
    Pawloski, Jacob A.
    Samir, Mariam
    Haider, Sameah
    Komatar, Ricardo J.
    Luther, Evan
    Morell, Alexis A.
    Ivan, Mike E.
    Robin, Adam M.
    Kalkanis, Steven N.
    Lee, Ian Y.
    JOURNAL OF NEURO-ONCOLOGY, 2024, 166 (02) : 265 - 272
  • [37] The VANILLA sensor as a beam monitoring device for X-ray radiation therapy
    Velthuis, J. J.
    Hugtenburg, R. P.
    Cussans, D.
    Perry, M.
    Hall, C.
    Stevens, P.
    Lawrence, H.
    McKenzie, A.
    APPLIED RADIATION AND ISOTOPES, 2014, 83 : 8 - 11
  • [38] X-RAY BEAM UNIFORMITY IN 250 KV DEEP THERAPY UNITS
    RAPLEY, LF
    ROUX, PLML
    STURROCK, P
    BRITISH JOURNAL OF RADIOLOGY, 1974, 47 (559): : 427 - 428
  • [39] Intravaginal x-ray deep radiation
    Teschendorf, W
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1939, 65 : 827 - 831
  • [40] X-RAY THERAPY AND THYROID TUMORS
    EPSTEIN, E
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1971, 215 (03): : 486 - &