Nonthermal mixing mechanism in a diffusion-cooled hot-electron detector

被引:16
|
作者
Semenov, AD [1 ]
Gol'tsman, GN [1 ]
机构
[1] Moscow State Pedag Univ, Dept Phys, Moscow 119435, Russia
关键词
D O I
10.1063/1.371890
中图分类号
O59 [应用物理学];
学科分类号
摘要
We present an analysis of a diffusion-cooled hot-electron detector fabricated from clean superconducting material with low transition temperature. The distinctive feature of a clean material, i.e., material with large electron mean free path, is a relatively weak inelastic electron scattering that is not sufficient for the establishment of an elevated thermodynamic electron temperature when the detector is subjected to irradiation. We propose an athermal model of a diffusion-cooled detector that relies on suppression of the superconducting energy gap by the actual dynamic distribution of excess quasiparticles. The resistive state of the device is caused by the electric field penetrating into the superconducting bridge from metal contacts. The dependence of the penetration length on the energy gap delivers the detection mechanism. The sources of the electric noise are equilibrium fluctuations of the number of thermal quasiparticles and frequency dependent shot noise. Using material parameters typical for A1, we evaluate performance of the device in the heterodyne regime at terahertz frequencies. Estimates show that the mixer may have a noise temperature of a few quantum limits and a bandwidth of a few tens of GHz, while the required local oscillator power is in the mu W range due to ineffective suppression of the energy gap by quasiparticles with high energies. (C) 2000 American Institute of Physics. [S0021-8979(99)01424-3].
引用
收藏
页码:502 / 510
页数:9
相关论文
共 50 条
  • [21] Diffusion-cooled superconducting hot electron bolometer heterodyne mixer between 630 and 820 GHz
    Fiegle, K
    Diehl, D
    Jacobs, K
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) : 3552 - 3555
  • [22] Spectrum of thermal fluctuation noise in diffusion and phonon cooled hot-electron mixers
    Burke, PJ
    Schoelkopf, RJ
    Prober, DE
    Skalare, A
    Karasik, BS
    Gaidis, MC
    McGrath, WR
    Bumble, B
    LeDuc, HG
    APPLIED PHYSICS LETTERS, 1998, 72 (12) : 1516 - 1518
  • [23] HOT-ELECTRON DIFFUSION IN CDTE
    CANALI, C
    CATELLANI, F
    JACOBONI, C
    MINDER, R
    OTTAVIANI, G
    ALBERIGIQUARANTA, A
    SOLID STATE COMMUNICATIONS, 1975, 17 (11) : 1443 - 1445
  • [24] HOT-ELECTRON DIFFUSION IN CDTE
    ROY, MD
    NAG, BR
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1983, 30 (03): : 189 - 193
  • [25] Diffusion cooling mechanism in a hot-electron NbC microbolometer mixer
    Karasik, BS
    Ilin, KS
    Pechen, EV
    Krasnosvobodtsev, SI
    APPLIED PHYSICS LETTERS, 1996, 68 (16) : 2285 - 2287
  • [26] Diffusion cooling mechanism in a hot-electron NbC microbolometer mixer
    Karasik, B.S.
    Il'in, K.S.
    Pechen, E.V.
    Krasnosvobodtsev, S.I.
    1996, (68):
  • [27] A hot-electron direct detector for radioastronomy
    Karasik, BS
    McGrath, WR
    LeDuc, HG
    Gershenson, ME
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1999, 12 (11): : 745 - 747
  • [28] MIXING BY HOT-ELECTRON EMF IN SEMICONDUCTORS
    PITANOV, VS
    LYUBIVY, VA
    RADIOTEKHNIKA I ELEKTRONIKA, 1984, 29 (11): : 2204 - 2209
  • [29] Hot-electron direct detector for radioastronomy
    Karasik, B.S.
    McGrath, W.R.
    LeDuc, H.G.
    Gershenson, M.E.
    Superconductor Science and Technology, 1999, 12 (11): : 745 - 747
  • [30] Fabrication of a diffusion cooled superconducting hot electron bolometer for THz mixing applications
    Bumble, Bruce
    LeDuc, Henry G.
    IEEE Transactions on Applied Superconductivity, 1997, 7 (2 pt 3) : 3560 - 3563