A free-running, time-based readout method for particle detectors

被引:6
|
作者
Goerres, A. [1 ]
Bugalho, R. [2 ]
Di Francesco, A. [2 ]
Gaston, C. [2 ]
Goncalves, F. [2 ]
Mazza, G. [3 ]
Mignone, M. [3 ]
Di Pietro, V. [3 ]
Riccardi, A. [3 ]
Ritman, J. [1 ]
Rivetti, A. [3 ]
Rolo, M. D. [2 ,3 ]
da Silva, J. C. [2 ]
Silva, R. [2 ]
Stockmanns, T. [1 ]
Varela, J. [2 ]
Veckalns, V. [2 ]
Wheadon, R. [3 ]
机构
[1] Forschungszentrum Julich, D-52428 Julich, Germany
[2] Lab Instrumentaccao & Fis Expt LIP Lisboa, P-1000149 Lisbon, Portugal
[3] Ist Nazl Fis Nucl, I-10125 Turin, Italy
来源
JOURNAL OF INSTRUMENTATION | 2014年 / 9卷
关键词
Electronic detector readout concepts (solid-state); Front-end electronics for detector readout; Si microstrip and pad detectors; Solid state detectors; OF-FLIGHT;
D O I
10.1088/1748-0221/9/03/C03025
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For the EndoTOFPET-US experiment, the TOFPET ASIC has been developed as a front-end chip to read out data from silicon photomultipliers (SiPM) [1]. It introduces a time of flight information into the measurement of a PET scanner and hence reduces radiation exposure of the patient [2]. The chip is designed to work with a high event rate up to 100 kHz and a time resolution of 50 ps LSB. Using two threshold levels, it can measure the leading edge of the event pulse precisely while successfully suppressing dark counts from the SiPM. This also enables a time over threshold determination, leading to a charge measurement of the signal's pulse. The same, time-based concept is chosen for the PASTA chip used in the PANDA experiment. This high-energy particle detector contains sub-systems for specific measurement goals. The innermost of these is the Micro Vertex Detector, a silicon-based tracking system. The PASTA chip's approach is much like the TOFPET ASIC with some differences. The most significant ones are a changed amplifying part for different input signals as well as protection for radiation effects of the high-radiation environment. Apart from that, the simple and general concept combined with a small area and low power consumption support the choice for using this approach.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Free-running ADC- and FPGA-based signal processing method for brain PET using GAPD arrays
    Hu, Wei
    Choi, Yong
    Hong, Key Jo
    Rang, Jihoon
    Jung, Jin Ho
    Huh, Youn Sul
    Lim, Hyun Keong
    Kim, Sang Su
    Kim, Byung-Tae
    Chung, Yonghyun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 664 (01): : 370 - 375
  • [42] Real-time dual-comb spectroscopy with a free-running femtosecond fiber laser
    Mehravar, S.
    Norwood, R. A.
    Peyghambarian, N.
    Kieu, K.
    2016 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2016,
  • [43] Statistical linearity calibration of time-to-digital converters using a free-running ring oscillator
    Rivoir, Jochen
    PROCEEDINGS OF THE 15TH ASIAN TEST SYMPOSIUM, 2006, : 45 - 50
  • [44] Analog Front-End for the Readout of LGAD-Based Particle Detectors
    Giroletti, Simone
    Brogi, Paolo
    Collazuol, Gianmaria
    Dalla Betta, Gian-Franco
    Manghisoni, Massimo
    Marrocchesi, Pier Simone
    Morsani, Fabio
    Pancheri, Lucio
    Ratti, Lodovico
    Vacchi, Carla
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1067
  • [45] Coherent Subcarrier Processing Node Based on Optical Frequency Conversion and Free-Running Lasers
    Richter, Thomas
    Schmidt-Langhorst, Carsten
    Elschner, Robert
    Kato, Tomoyuki
    Tanimura, Takahito
    Watanabe, Shigeki
    Schubert, Colja
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2015, 33 (03) : 685 - 693
  • [46] APPROACHES TO THE TUNNELING TIME-BASED ON THE LARMOR CLOCK AND PARTICLE ABSORPTION AS PARTICULAR CASES OF THE STAY-TIME METHOD
    IANNACCONE, G
    PELLEGRINI, B
    PHYSICAL REVIEW B, 1994, 50 (19): : 14659 - 14662
  • [47] THE DEVELOPMENT IN TIME OF AMPLITUDE AND SHAPE OF THE FREE-RUNNING CIRCADIAN LEAF MOVEMENT IN OXALIS-REGNELLII
    KUMKE, JM
    JOURNAL OF INTERDISCIPLINARY CYCLE RESEARCH, 1982, 13 (02): : 105 - 120
  • [48] Investigation of a high precision ranging system based on free-running dual comb ranging
    Yang, Fu
    Ning, Yan
    Deng, Bowen
    Zhou, Jiaqi
    Ye, Qing
    Long, Wei
    OPTICS COMMUNICATIONS, 2025, 578
  • [49] Free-space optical interconnects for cable-less readout in particle physics detectors
    Chramowicz, J.
    Kwan, S.
    Moretti, T.
    Sugg, A.
    Prosser, A.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [50] Online Identification Method of Nonlinear Ship Motion Mathematical Models from Free-Running Tests
    Zheng, Jian
    Li, Yun
    Meng, Fei
    2019 IEEE 28TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2019, : 1930 - 1936