A free-running, time-based readout method for particle detectors

被引:6
|
作者
Goerres, A. [1 ]
Bugalho, R. [2 ]
Di Francesco, A. [2 ]
Gaston, C. [2 ]
Goncalves, F. [2 ]
Mazza, G. [3 ]
Mignone, M. [3 ]
Di Pietro, V. [3 ]
Riccardi, A. [3 ]
Ritman, J. [1 ]
Rivetti, A. [3 ]
Rolo, M. D. [2 ,3 ]
da Silva, J. C. [2 ]
Silva, R. [2 ]
Stockmanns, T. [1 ]
Varela, J. [2 ]
Veckalns, V. [2 ]
Wheadon, R. [3 ]
机构
[1] Forschungszentrum Julich, D-52428 Julich, Germany
[2] Lab Instrumentaccao & Fis Expt LIP Lisboa, P-1000149 Lisbon, Portugal
[3] Ist Nazl Fis Nucl, I-10125 Turin, Italy
来源
关键词
Electronic detector readout concepts (solid-state); Front-end electronics for detector readout; Si microstrip and pad detectors; Solid state detectors; OF-FLIGHT;
D O I
10.1088/1748-0221/9/03/C03025
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For the EndoTOFPET-US experiment, the TOFPET ASIC has been developed as a front-end chip to read out data from silicon photomultipliers (SiPM) [1]. It introduces a time of flight information into the measurement of a PET scanner and hence reduces radiation exposure of the patient [2]. The chip is designed to work with a high event rate up to 100 kHz and a time resolution of 50 ps LSB. Using two threshold levels, it can measure the leading edge of the event pulse precisely while successfully suppressing dark counts from the SiPM. This also enables a time over threshold determination, leading to a charge measurement of the signal's pulse. The same, time-based concept is chosen for the PASTA chip used in the PANDA experiment. This high-energy particle detector contains sub-systems for specific measurement goals. The innermost of these is the Micro Vertex Detector, a silicon-based tracking system. The PASTA chip's approach is much like the TOFPET ASIC with some differences. The most significant ones are a changed amplifying part for different input signals as well as protection for radiation effects of the high-radiation environment. Apart from that, the simple and general concept combined with a small area and low power consumption support the choice for using this approach.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Versatile free-running ADC-based data acquisition system for particle detectors
    Jokhovets, L.
    Kulessa, P.
    Erven, A.
    Grewing, C.
    von der Gracht, T. Hahnraths
    Harff, M.
    Ohm, H.
    Pysz, K.
    Ritman, J.
    Roth, C.
    Schloesser, M.
    Sefzick, T.
    Serdyuk, V
    Waasen, S. v.
    Wintz, P.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (04):
  • [2] A SoC-FPGA based readout platform for the free-running AMBER data acquisition system
    Valinoti, B.
    Samayoa, W. O. Florian
    Garcia, L. G.
    Crespo, M. L.
    Cicuttin, A.
    Levorato, S.
    Tessarotto, F.
    Bressan, A.
    Konorov, I.
    Pastuszak, G.
    Ziembicki, M.
    Dygnarowicz, K.
    Galinski, G.
    Buchowicz, A.
    Veit, B. M.
    Donskov, S.
    Polyakov, V. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1066
  • [3] RITZ METHOD IN THE THEORY OF GENERALIZED FREE-RUNNING OSCILLATIONS
    DIKAREV, VA
    RADIOTEKHNIKA I ELEKTRONIKA, 1981, 26 (01): : 18 - 26
  • [4] Hybrid charge division multiplexing: a feasibility study for the time-based readout of SiPM-based PET detectors
    Park, Haewook
    Ko, Guen Bae
    Lee, Jae Sung
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [5] Precise synchronization of a free-running Rubidium atomic clock with GPS Time for applications in experimental particle physics
    Dalmazzone, Claire
    Guigue, Mathieu
    Mellet, Lucile
    Popov, Boris
    Russo, Stefano
    Voisin, Vincent
    Abgrall, Michel
    Chupin, Baptiste
    Lim, Caroline B.
    Pottie, Paul-eric
    Ulrich, Pierre
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1075
  • [6] A Time-Based CMOS Readout Circuit for Amperometric Biosensors
    Ashrafirad, Hanieh
    Valente, Virgilio
    2023 18TH CONFERENCE ON PH.D RESEARCH IN MICROELECTRONICS AND ELECTRONICS, PRIME, 2023, : 117 - 120
  • [7] Research and development for a free-running readout system for the ATLAS LAr Calorimeters at the high luminosity LHC
    Hils, Maximilian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 296 - 298
  • [8] Temporal jitter in free-running InGaAs/InP single-photon avalanche detectors
    Amri, Emna
    Boso, Gianluca
    Korzh, Boris
    Zbinden, Hugo
    OPTICS LETTERS, 2016, 41 (24) : 5728 - 5731
  • [9] A study to develop a robust method for measuring the detection efficiency of free-running InGaAs/InP single-photon detectors
    Lopez, M.
    Meda, A.
    Porrovecchio, G.
    Starkwood , R. A.
    Genovese, M.
    Brida, G.
    Smid, M.
    Chunnilall, C. J.
    Degiovanni, I. P.
    Kuck, S.
    EPJ QUANTUM TECHNOLOGY, 2020, 7 (01)
  • [10] A study to develop a robust method for measuring the detection efficiency of free-running InGaAs/InP single-photon detectors
    M. López
    A. Meda
    G. Porrovecchio
    R. A. Starkwood (Kirkwood)
    M. Genovese
    G. Brida
    M. Šmid
    C. J. Chunnilall
    I. P. Degiovanni
    S. Kück
    EPJ Quantum Technology, 2020, 7