Effect of lens base curve on subjective comfort and assessment of fit with silicone hydrogel continuous wear contact lenses

被引:29
|
作者
Dumbleton, KA
Chalmers, RL
McNally, J
Bayer, S
Fonn, D
机构
[1] Ciba Vis Corp, Duluth, GA USA
[2] Univ Waterloo, Ctr Contact Lens Res, Waterloo, ON N2L 3G1, Canada
关键词
base curve; trial fitting procedures; silicone hydrogel contact lenses; subjective comfort; contact lenses; lens design;
D O I
10.1097/00006324-200210000-00008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To study the effect of base curve on subjective comfort of silicone hydrogel extended wear lenses. Methods. Ninety-five subjects were first trial fitted with 8.6-mm base curve lotrafilcon A (Focus Night & Day) lenses and then with 8.4-mm lenses only if poor subjective comfort or poor fit was present. Comfort and fit were assessed after 15 min. Subjects with discomfort or signs of poor fit were then trial fitted with 8.4-mm lenses. Results. Of 190 eyes, 74.2% were fitted with 8.6-mm lenses, and 23.7% required 8.4-mm lenses. Two (2.1%) subjects could not be fitted with either base curve. Mean steep keratometry (K) reading for eyes dispensed with 8.6-mm lenses was 43.88 D and 45.56 D for eyes dispensed in the 8.4-mm lenses (p < 0.001). Conclusions. A clinically useful criterion showing the need for 8.4-mm lenses was steep K of greater than or equal to45.50 D; 77% of these eyes required the steeper lens for good comfort and fit. Subjective discomfort with 8.6-mm lenses was also a useful signal for the need of a steeper lens; mean comfort scores for those subjects rose from 6.33 with 8.6-mm lenses to 9.44 with the 8.4-mm lenses for eyes requiring the steeper lens (p < 0.001).
引用
收藏
页码:633 / 637
页数:5
相关论文
共 50 条
  • [41] The efficiency of contact lens care regimens on protein removal from hydrogel and silicone hydrogel lenses
    Luensmann, Doerte
    Heynen, Miriam
    Liu, Lina
    Sheardown, Heather
    Jones, Lyndon
    MOLECULAR VISION, 2010, 16 (10-11): : 79 - 92
  • [42] Daily Wear Contact Lenses Manufactured in Etafilcon A Are Noninferior to Two Silicone Hydrogel Lens Types With Respect to Hypoxic Stress
    Szczotka-Flynn, Loretta B.
    Debanne, Sara
    Benetz, Beth Ann
    Wilson, Tawnya
    Brennan, Noel
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 (03): : 190 - 199
  • [43] Daily Instillation of Antibiotic Drops During Continuous Wear of Silicone Hydrogel Lenses
    Ozkan, J.
    Zhu, H.
    Gabriel, M. M.
    Willcox, M.
    Holden, B. A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [44] Effects of Multipurpose Contact Lens Care Solutions on the Adhesion of Acanthamoeba to Silicone Hydrogel Contact Lenses
    Uno, Toshihiko
    Ohashi, Yuichi
    Nomachi, Miya
    Imayasu, Masaki
    CORNEA, 2012, 31 (10) : 1170 - 1175
  • [45] The effect of patient wear on the attachment of Acanthamoeba to Acuvue Advance, second generation, silicone hydrogel contact lenses
    Tomlinson, A
    Beattie, TK
    McFadyen, AK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [46] The incidence of local and general contact lens induced papillary conjunctivitis in silicone hydrogel contact lenses
    Skotnitsky, CC
    Sweeney, DF
    Naduvilath, TJ
    Sankaridurg, PR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [47] Effect of Lens Care Systems on Silicone Hydrogel Contact Lens Hydrophobicity
    Lira, Madalena
    Silva, Rita
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (02): : 89 - 94
  • [48] Effect of lens care system on silicone hydrogel contact lens wettability
    Maissa, Cecile
    Guillon, Michel
    Wong, Stephanie
    Lane, Anna
    Patel, Trisha
    Garofalo, Renee
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [49] Effect of lens care system on silicone hydrogel contact lens wettability
    Guillon, Michel
    Maissa, Cecile
    Wong, Stephanie
    Patel, Trisha
    Garofalo, Renee
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (06): : 435 - 441
  • [50] Hydrogel lens dehydration and subjective comfort and dryness ratings in symptomatic and asymptomatic contact lens wearers
    Fonn, D
    Situ, P
    Simpson, T
    OPTOMETRY AND VISION SCIENCE, 1999, 76 (10) : 700 - 704