Simultaneous amperometric and potentiometric detection of sugars, polyols and carboxylic acids in flow systems using copper wire electrodes

被引:58
|
作者
Chen, ZL [1 ]
Hibbert, DB [1 ]
机构
[1] UNIV NEW S WALES, DEPT ANALYT CHEM, SYDNEY, NSW 205502, AUSTRALIA
关键词
copper electrodes; amperometic detection; potentiometric detection; detection; LC; polyols; carboxylic acids; carbohydrates;
D O I
10.1016/S0021-9673(96)00971-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Copper wire electrodes, used for amperometric and potentiometric detection in flow injection analysis and highperformance liquid chromatography, have been developed for the 'simultaneous' detection of sugars, polyols and carboxylic acids. Sugars and polyols were oxidised at +0.5 V (versus Ag\AgCl\0.1 M Cl-) in 100 mM NaOH and citric acid was potentiometrically detected at a copper wire in Milli-Q water. Citric acid, acetic acid, glucose, fructose, glycerol and ethanol were separated by ion-exclusion chromatography with water as eluent and passed through the potentiometric detector then the amperometric detector after addition of 100 mM NaOH. The amperometric detector gave detection limits of 5, 5, 2 and 80 pmol for glucose, fructose, glycerol and ethanol, respectively, with a linear response over 3 decades (10(-6)-10(-3) M). For the potentiometric detector, the detection limits were 10 and 50 pmol for citric acid and acetic acid and linearity was in range of 10(-5) M-10(-3) M. Compared with a universal detector such as refractive index, the reported combination electrochemical detector shows high sensitivity and low detection limits.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 50 条
  • [21] POTENTIOMETRIC DETECTION OF CARBOXYLIC-ACIDS AND INORGANIC ANIONS IN ION-EXCLUSION CHROMATOGRAPHY USING CAMPHORSULPHONIC ACID AS ELUENT
    GLOD, BK
    HADDAD, PR
    ALEXANDER, PW
    JOURNAL OF CHROMATOGRAPHY, 1992, 589 (1-2): : 209 - 214
  • [22] Direct and simultaneous determination of amino acids and sugars in rice wine by high-performance anion-exchange chromatography with integrated pulsed amperometric detection
    H. Yu
    Y. S. Ding
    S. F. Mou
    Chromatographia, 2003, 57 : 721 - 728
  • [23] Direct and simultaneous determination of amino acids and sugars in rice wine by high-performance anion-exchange chromatography with integrated pulsed amperometric detection
    Yu, H
    Ding, YS
    Mou, SF
    CHROMATOGRAPHIA, 2003, 57 (11-12) : 721 - 728
  • [24] Flow-injection potentiometric detection of phosphates using a metallic cobalt wire ion-selective electrode
    Chen, ZL
    DeMarco, R
    Alexander, PW
    ANALYTICAL COMMUNICATIONS, 1997, 34 (03): : 93 - 95
  • [25] Application of Prussian Blue electrodes for amperometric detection of free chlorine in water samples using Flow Injection Analysis
    Salazar, Pedro
    Martin, Miriam
    Luis Gonzalez-Mora, Jose
    Gonzalez-Elipe, Agustin R.
    TALANTA, 2016, 146 : 410 - 416
  • [26] Amperometric detection of hydrazine by cyclic voltammetry and flow injection analysis using ruthenium modified glassy carbon electrodes
    Pinter, Jill S.
    Brown, Kenneth L.
    DeYoung, Paul A.
    Peaslee, Graham F.
    TALANTA, 2007, 71 (03) : 1219 - 1225
  • [27] Flow injection amperometric detection of catechol using dual-band poly(3-methylthiophene) electrodes
    Zhang, H
    Galal, A
    Rubinson, JF
    Marawi, I
    Ridgway, TH
    Lunsford, SK
    Zimmer, H
    Mark, HB
    ELECTROCHIMICA ACTA, 1998, 43 (23) : 3511 - 3524
  • [28] AMPEROMETRIC DETECTION OF AMINES AND AMINO-ACIDS IN FLOW-INJECTION SYSTEMS WITH A NICKEL-OXIDE ELECTRODE
    HUI, BS
    HUBER, CO
    ANALYTICA CHIMICA ACTA, 1982, 134 (JAN) : 211 - 218
  • [29] Simultaneous determination of copper, lead and zinc in alloy by potentiometric titration coupled with multivariate calibration using a flow injection technique
    Deng, Changai
    Liao, Lifu
    Long, Wei
    CURRENT TRENDS IN THE DEVELOPMENT OF INDUSTRY, PTS 1 AND 2, 2013, 785-786 : 1353 - 1358
  • [30] A Simple Strategy for Simultaneous Determination of Paracetamol and Caffeine Using Flow Injection Analysis with Multiple Pulse Amperometric Detection
    Silva, Wesley C.
    Pereira, Polyana F.
    Marra, Mariana C.
    Gimenes, Denise T.
    Cunha, Rafael R.
    da Silva, Rodrigo A. B.
    Munoz, Rodrigo A. A.
    Richter, Eduardo M.
    ELECTROANALYSIS, 2011, 23 (12) : 2764 - 2770