Methods of Blood Oxygen Level-Dependent Magnetic Resonance Imaging Analysis for Evaluating Renal Oxygenation

被引:30
|
作者
Chen, Fen [1 ]
Li, Shulin [1 ,2 ]
Sun, Dong [1 ,2 ]
机构
[1] Xuzhou Med Univ, Dept Nephrol, Xuzhou, Jiangsu, Peoples R China
[2] Xuzhou Med Univ, Affiliated Hosp, Dept Nephrol, 99 West Huai Hai Rd, Xuzhou 221002, Jiangsu, Peoples R China
来源
KIDNEY & BLOOD PRESSURE RESEARCH | 2018年 / 43卷 / 02期
基金
中国国家自然科学基金;
关键词
Blood oxygen level-dependent; Magnetic resonance imaging; Kidney; Oxygen; Hypoxia; Methods; CHRONIC KIDNEY-DISEASE; UNILATERAL URETERAL OBSTRUCTION; HUMAN RENOVASCULAR DISEASE; RENIN-ANGIOTENSIN SYSTEM; BOLD-MRI; INTRARENAL OXYGENATION; TISSUE OXYGENATION; ARTERY STENOSIS; NONINVASIVE EVALUATION; HYPERTENSIVE PATIENTS;
D O I
10.1159/000488072
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Blood oxygen level-dependent magnetic resonance imaging (BOLD MRI) has recently been utilized as a noninvasive tool for evaluating renal oxygenation. Several methods have been proposed for analyzing BOLD images. Regional ROI selection is the earliest and most widely used method for BOLD analysis. In the last 20 years, many investigators have used this method to evaluate cortical and medullary oxygenation in patients with ischemic nephropathy, hypertensive nephropathy, diabetic nephropathy, chronic kidney disease (CKD), acute kidney injury and renal allograft rejection. However, clinical trials of BOLD MRI using regional ROI selection revealed that it was difficult to distinguish the renal cortico-medullary zones with this method, and that it was susceptible to observer variability. To overcome these deficiencies, several new methods were proposed for analyzing BOLD images, including the compartmental approach, fractional hypoxia method, concentric objects (CO) method and twelve-layer concentric objects (TLCO) method. The compartmental approach provides an algorithm to judge whether the pixel belongs to the cortex or medulla. Fractional kidney hypoxia, measured by using BOLD MRI, was negatively correlated with renal blood flow, tissue perfusion and glomerular filtration rate (GFR) in patients with atherosclerotic renal artery stenosis. The CO method divides the renal parenchyma into six or twelve layers of thickness in each coronal slice of BOLD images and provides a R2* radial profile curve. The slope of the R2* curve associated positively with eGFR in CKD patients. Indeed, each method invariably has advantages and disadvantages, and there is generally no consensus method so far. Undoubtedly, analytic approaches for BOLD MRI with better reproducibility would assist clinicians in monitoring the degree of kidney hypoxia and thus facilitating timely reversal of tissue hypoxia. (C) 2018 The Author(s) Published by S. Karger AG, Basel.
引用
收藏
页码:378 / 388
页数:11
相关论文
共 50 条
  • [41] Emotion processing in Parkinson's disease: a blood oxygenation level-dependent functional magnetic resonance imaging study
    Mohammed Benzagmout
    Sa?d Boujraf
    Badreeddine Alami
    Hassane Ali Amadou
    Halima El Hamdaoui
    Amine Bennani
    Mounir Jaafari
    Ismail Rammouz
    Mustapha Maaroufi
    Rabia Magoul
    Driss Boussaoud
    Neural Regeneration Research, 2019, 14 (04) : 666 - 672
  • [42] Detection of renal allograft rejection using blood oxygen level-dependent and diffusion weighted magnetic resonance imaging: a retrospective study
    Liu, Guangyi
    Han, Fei
    Xiao, Wenbo
    Wang, Qidong
    Xu, Ying
    Chen, Jianghua
    BMC NEPHROLOGY, 2014, 15
  • [43] Detection of renal allograft rejection using blood oxygen level-dependent and diffusion weighted magnetic resonance imaging: a retrospective study
    Guangyi Liu
    Fei Han
    Wenbo Xiao
    Qidong Wang
    Ying Xu
    Jianghua Chen
    BMC Nephrology, 15
  • [44] Blood oxygen level-dependent imaging for evaluating C3 glomerulonephritis
    Nishino, Tomohiko
    Takahashi, Kazuhiro
    Ono, Sayaka
    Mimaki, Masakazu
    PEDIATRICS INTERNATIONAL, 2021, 63 (11) : 1386 - 1388
  • [45] Emotion processing in Parkinson's disease: a blood oxygenation level-dependent functional magnetic resonance imaging study
    Benzagmout, Mohammed
    Boujraf, Said
    Alami, Badreeddine
    Amadou, Hassane Ali
    El Hamdaoui, Halima
    Bennani, Amine
    Jaafari, Mounir
    Rammouz, Ismail
    Maaroufi, Mustapha
    Magoul, Rabia
    Boussaoud, Driss
    NEURAL REGENERATION RESEARCH, 2019, 14 (04) : 666 - 672
  • [46] Evaluating renal iron overload in diabetes mellitus by blood oxygen level-dependent magnetic resonance imaging: a longitudinal experimental study (vol 22, 200, 2022)
    Geng, Weiwei
    Pan, Liang
    Shen, Liwen
    Sha, Yuanyuan
    Sun, Jun
    Yu, Shengnan
    Qiu, Jianguo
    Xing, Wei
    BMC MEDICAL IMAGING, 2024, 24 (01)
  • [47] Blood oxygen level-dependent and perfusion magnetic resonance imaging: detecting differences in oxygen bioavailability and blood flow in transplanted kidneys
    Sadowski, Elizabeth A.
    Djamali, Arjang
    Wentland, Andrew L.
    Muehrer, Rebecca
    Becker, Bryan N.
    Grist, Thomas M.
    Fain, Sean B.
    MAGNETIC RESONANCE IMAGING, 2010, 28 (01) : 56 - 64
  • [48] Blood Oxygen Level-Dependent Magnetic Resonance Imaging Identifies Cortical Hypoxia in Severe Renovascular Disease
    Gloviczki, Monika L.
    Glockner, James F.
    Crane, John A.
    McKusick, Michael A.
    Misra, Sanjay
    Grande, Joseph P.
    Lerman, Lilach O.
    Textor, Stephen C.
    HYPERTENSION, 2011, 58 (06) : 1066 - U194
  • [49] Characterizing the Blood Oxygen Level-Dependent Fluctuations in Musculoskeletal Tumours Using Functional Magnetic Resonance Imaging
    Li-Sha Duan
    Meng-Jun Wang
    Feng Sun
    Zhen-Jiang Zhao
    Mei Xing
    Yu-Feng Zang
    Steven Louis
    Sheng-Jie Cui
    Jian-Ling Cui
    Han Zhang
    Scientific Reports, 6
  • [50] Resting-State Blood Oxygen Level-Dependent Functional Magnetic Resonance Imaging for Presurgical Planning
    Kamran, Mudassar
    Hacker, Carl D.
    Allen, Monica G.
    Mitchell, Timothy J.
    Leuthardt, Eric C.
    Snyder, Abraham Z.
    Shimony, Joshua S.
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2014, 24 (04) : 655 - +