New stent delivery balloon: A technical note

被引:0
|
作者
diMario, C
Reimers, B
Reinhardt, R
Ferraro, M
Moussa, I
Colombo, A
机构
[1] COLUMBUS CLIN,MILAN,ITALY
[2] JOHNSON & JOHNSON INTERVENT SYST,DEPT RES & DEV,WARREN,NJ
来源
关键词
coronary stenting; balloon catheters; balloon angioplasty;
D O I
10.1002/(SICI)1097-0304(199712)42:4<452::AID-CCD28>3.0.CO;2-K
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study reports the first clinical application of a new noncompliant balloon composed of a middle polyurethane layer sandwiched between an inner layer of polyethylene terephtalate and an outer membrane that provides for consistent even expansion. With this balloon design, the very low compliance and high pressure resistance of polyethylene terephthalate are associated with the high elasticity of polyurethane, preventing balloon damage from stent crimping and expansion and allowing a firm embedding of the stent struts. Palmaz-Schatz stent implantation was successful in 33/35 stents (94%), and the two stents that could not be advanced up to the lesion were successfully withdrawn, High pressure expansion of the stent was obtained during deployment with no balloon ruptures at inflation pressures equal or lower than 16 atmospheres (atm). Accurate positioning of the stent was facilitated by the two markers at the balloon ends and by the optimal visualization after contrast injection, even with 6 Fr guiding catheters. This new delivery system maintains the advantages of hand-crimped stents on noncompliant balloons, reducing the risk of stent loss. (C) 1997 Wiley-Liss, Inc.
引用
收藏
页码:452 / 456
页数:5
相关论文
共 50 条
  • [41] TECHNICAL NOTE - 2 BALLOON TECHNIQUE FOR DISIMPACTION OF INTRAHEPATIC BILIARY STONES
    REDMOND, PL
    KUMPE, DA
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1989, 12 (01) : 45 - 46
  • [42] Balloon-assisted microcatheter navigation for AVM embolization: technical note
    Mendes, George A. C.
    Silveira, Eduardo Pedrolo
    Saleme, Suzana
    Losif, Christina
    Ponomarjova, Sanita
    Caire, Francois
    Mounayer, Charbel
    JOURNAL OF NEUROSURGERY, 2015, 123 (05) : 1120 - 1124
  • [43] Balloon-assisted microvascular clipping of paraclinoid aneurysms - Technical note
    Thorell, W
    Rasmussen, P
    Perl, J
    Masaryk, T
    Mayberg, M
    JOURNAL OF NEUROSURGERY, 2004, 100 (04) : 713 - 716
  • [44] INDWELLING DOUBLE-BALLOON SHUNT FOR CAROTID ENDARTERECTOMY - TECHNICAL NOTE
    FURUI, T
    HASUO, M
    JOURNAL OF NEUROSURGERY, 1984, 60 (04) : 861 - 863
  • [45] BALLOON RUPTURE DURING PERIPHERAL STENT IMPLANTATION - A NEW TECHNIQUE FOR BALLOON RETRIEVAL
    BERSIN, RM
    GOLD, RS
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 29 (04): : 292 - 295
  • [47] Combined use of a double-lumen remodeling balloon and a low-profile stent in the treatment of intracranial aneurysms ('remostent' technique): A technical note
    Kadziolka, Krzysztof
    Tomas, Catherine
    Robin, Georges
    Pierot, Laurent
    JOURNAL OF NEURORADIOLOGY, 2013, 40 (01) : 50 - 53
  • [48] Covered stent-graft repair of the brachiocephalic arteries: Technical note
    Amar, AP
    Teitelbaum, GP
    Giannotta, SL
    Larsen, DW
    NEUROSURGERY, 2002, 51 (01) : 247 - 252
  • [49] A NEW BRAIN RETRACTOR - TECHNICAL NOTE
    MIYAKE, H
    OHTA, T
    JOURNAL OF NEUROSURGERY, 1993, 79 (03) : 462 - 463
  • [50] A NEW CLIP APPLIER - TECHNICAL NOTE
    MCFADDEN, JT