New stent delivery balloon: A technical note

被引:0
|
作者
diMario, C
Reimers, B
Reinhardt, R
Ferraro, M
Moussa, I
Colombo, A
机构
[1] COLUMBUS CLIN,MILAN,ITALY
[2] JOHNSON & JOHNSON INTERVENT SYST,DEPT RES & DEV,WARREN,NJ
来源
关键词
coronary stenting; balloon catheters; balloon angioplasty;
D O I
10.1002/(SICI)1097-0304(199712)42:4<452::AID-CCD28>3.0.CO;2-K
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study reports the first clinical application of a new noncompliant balloon composed of a middle polyurethane layer sandwiched between an inner layer of polyethylene terephtalate and an outer membrane that provides for consistent even expansion. With this balloon design, the very low compliance and high pressure resistance of polyethylene terephthalate are associated with the high elasticity of polyurethane, preventing balloon damage from stent crimping and expansion and allowing a firm embedding of the stent struts. Palmaz-Schatz stent implantation was successful in 33/35 stents (94%), and the two stents that could not be advanced up to the lesion were successfully withdrawn, High pressure expansion of the stent was obtained during deployment with no balloon ruptures at inflation pressures equal or lower than 16 atmospheres (atm). Accurate positioning of the stent was facilitated by the two markers at the balloon ends and by the optimal visualization after contrast injection, even with 6 Fr guiding catheters. This new delivery system maintains the advantages of hand-crimped stents on noncompliant balloons, reducing the risk of stent loss. (C) 1997 Wiley-Liss, Inc.
引用
收藏
页码:452 / 456
页数:5
相关论文
共 50 条
  • [1] Repositioning of a misplaced ureteral stent with a balloon catheter: Technical note
    Ilgit, ET
    Akpek, S
    Isik, S
    EUROPEAN JOURNAL OF RADIOLOGY, 1997, 24 (03) : 257 - 259
  • [2] Improved delivery of the Neuroform 3 stent: technical note
    Ferrell, Andrew Stephen
    Golshani, Kiarash
    Zomorodi, Ali
    Smith, Tony P.
    Britz, Gavin W.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2012, 4 (04) : 287 - 290
  • [3] Dislodged Stent Due to Stent Delivery Balloon Rupture
    Miyai, Nobuyuki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : S156 - S156
  • [4] A NEW TYPE OF ADJUSTABLE VASCULAR INTRODUCER FOR BALLOON VALVULOPLASTY - TECHNICAL NOTE
    MEDINA, A
    BETHENCOURT, A
    COELLO, I
    HERNANDEZ, E
    GOICOLEA, J
    MELIAN, F
    LARAUDOGOITIA, E
    JIMENEZ, F
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1989, 12 (03) : 169 - 171
  • [5] In-stent restenosis: local drug delivery with a stent or balloon?
    Yudi, Matias B.
    Waksman, Ron
    Ajani, Andrew E.
    JOURNAL OF THORACIC DISEASE, 2015, 7 (10) : 1691 - 1692
  • [6] PERCUTANEOUS DEFLATION OF A GASTRIC BALLOON - TECHNICAL NOTE
    MIRICH, DR
    GRAY, RR
    HABER, GB
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1989, 12 (03) : 164 - 165
  • [7] Balloon anchoring to traverse the sigmoid sinus for delivery of large-caliber venous stents: A technical note
    Murakami, Tomoaki
    Toyota, Shingo
    Suematsu, Takuya
    Wada, Yuki
    Nakagawa, Kanji
    Shimizu, Takeshi
    Mori, Kanji
    Taki, Takuyu
    INTERVENTIONAL NEURORADIOLOGY, 2021, 27 (05) : 712 - 715
  • [8] DOUBLE MARKER ACX-II - A NEW BALLOON CATHETER FOR CORONARY STENT DELIVERY
    BROWN, RIG
    PENN, IM
    RICCI, DR
    BULLER, CE
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 27 (01): : 82 - 85
  • [9] A NEW SURGICAL APPROACH TO SUBCORTICAL LESIONS - BALLOON INFLATION AND CORTICAL GLUING - TECHNICAL NOTE
    HIRSCH, JF
    SAINTEROSE, C
    JOURNAL OF NEUROSURGERY, 1991, 74 (06) : 1014 - 1017
  • [10] A modified technique of balloon anchoring for tricky stent delivery
    Aeby, Guillaume
    Surmely, Jean-Francois
    Togni, Mario
    Cook, Stephane
    EUROINTERVENTION, 2013, 8 (09) : 1099 - 1102