A feedback constraint optimization method for intensity-modulated radiation therapy of nasopharyngeal carcinoma

被引:1
|
作者
Li, Yongwu [1 ]
Sun, Xiaonan [1 ]
Wang, Qi [1 ]
Zhou, Qinxuan [1 ]
Gu, Benxing [1 ]
Shi, Guozhi [1 ]
Jiang, Dongliang [1 ]
机构
[1] Zhejiang Univ, Coll Med, Sir Run Run Shaw Hosp, Dept Radiat Oncol, Hangzhou 310000, Zhejiang, Peoples R China
关键词
feedback constraint optimization; nasopharyngeal carcinoma; radiation therapy; dose; MACHINE PARAMETER OPTIMIZATION; 2-STEP IMRT; NUMBER; IMAT;
D O I
10.3892/ol.2015.3523
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Intensity-modulated radiation therapy (IMRT) is able to achieve good target conformance with a limited dose to organs at risk (OARs); however, IMRT increases the irradiation volume and monitor units (MUs) required. The present study aimed to evaluate the use of an IMRT plan with fewer segments and MUs, while maintaining quality in the treatment of nasopharyngeal carcinoma. In the present study, two types of IMRT plan were therefore compared: The direct machine parameter optimization (DMPO)-RT method and the feedback constraint DMPO-RT (fc_DMPO-RT) method, which utilizes compensative feedback constraint in DMPO-RT and maintains optimization. Plans for 23 patients were developed with identical dose prescriptions. Each plan involved synchronous delivery to various targets, with identical OAR constraints, by means of 7 coplanar fields. The average dose, maximum dose, dose-volume histograms of targets and the OAR, MUs of the plan, the number of segments, delivery time and accuracy were subsequently compared. The fc_DMPO-RT exhibited superior dose distribution in terms of the average, maximum and minimum doses to the gross tumor volume compared with that of DMPO-RT (t=62.7, 20.5 and 22.0, respectively; P<0.05). The fc_DMPO-RT also resulted in a smaller maximum dose to the spinal cord (t=7.3; P<0.05), as well as fewer MUs, fewer segments and decreased treatment times than that of the DMPO-RT (t=6.2, 393.4 and 244.3, respectively; P<0.05). The fc_DMPO-RT maintained plan quality with fewer segments and MUs, and the treatment time was significantly reduced, thereby resulting in reduced radiation leakage and an enhanced curative effect. Therefore, introducing feedback constraint into DMPO may result in improved IMRT planning. In nasopharyngeal carcinoma specifically, feedback constraint resulted in the improved protection of OARs in proximity of targets (such as the brainstem and parotid) due to sharp dose distribution and reduced MUs.
引用
收藏
页码:2043 / 2050
页数:8
相关论文
共 50 条
  • [41] Effectiveness and Toxicities of Intensity-Modulated Radiation Therapy for Patients with T4 Nasopharyngeal Carcinoma
    Kong, Fang-fang
    Ying, Hongmei
    Du, Cheng-run
    Huang, Shuang
    Zhou, Jun-jun
    Hu, Chao-su
    PLOS ONE, 2014, 9 (03):
  • [42] Iterative regularization in intensity-modulated radiation therapy optimization
    Carlsson, F
    Forsgren, A
    MEDICAL PHYSICS, 2006, 33 (01) : 225 - 234
  • [43] Issues in optimization for planning of intensity-modulated radiation therapy
    Verhey, LJ
    SEMINARS IN RADIATION ONCOLOGY, 2002, 12 (03) : 210 - 218
  • [44] Neutrophil-Lymphocyte Ratio in Locally Recurrent Nasopharyngeal Carcinoma Patients Treated With Intensity-Modulated Carbon-Ion Radiation Therapy Versus Intensity-Modulated Radiation Therapy
    Kong, L.
    Wang, S. Z.
    Hu, C.
    Hu, J.
    Lu, J. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E348 - E349
  • [45] Study on the Optimization Algorithms for Intensity-Modulated Radiation Therapy
    LI Yong-jie (School of School of Life Science
    Journal of Electronic Science and Technology of China, 2005, (01) : 95 - 96
  • [46] Influence of intensity-modulated radiation therapy technique on xerostomia and related quality of life in patients treated with intensity-modulated radiation therapy for nasopharyngeal cancer
    Marucci, Laura
    Marzi, Simona
    Sperduti, Isabella
    Giovinazzo, Giuseppe
    Pinnaro, Paola
    Benassi, Marcello
    Strigari, Lidia
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2012, 34 (03): : 328 - 335
  • [47] Comparison of Intensity-Modulated Radiation Therapy, Intensity-Modulated Arc Therapy and Arc-Modulated Radiation Therapy
    Tang, G.
    Earl, M.
    Luan, S.
    Wang, C.
    Naqvi, S.
    Yu, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [48] Intensity-modulated radiation therapy
    Lewin, DI
    COMPUTING IN SCIENCE & ENGINEERING, 2002, 4 (05) : 8 - 10
  • [49] Intensity-modulated radiation therapy
    Purdy, JA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (04): : 845 - 846
  • [50] Intensity-modulated radiation therapy
    Anon
    Computing in Science and Engineering, 2002, 4 (05):