A feedback constraint optimization method for intensity-modulated radiation therapy of nasopharyngeal carcinoma

被引:1
|
作者
Li, Yongwu [1 ]
Sun, Xiaonan [1 ]
Wang, Qi [1 ]
Zhou, Qinxuan [1 ]
Gu, Benxing [1 ]
Shi, Guozhi [1 ]
Jiang, Dongliang [1 ]
机构
[1] Zhejiang Univ, Coll Med, Sir Run Run Shaw Hosp, Dept Radiat Oncol, Hangzhou 310000, Zhejiang, Peoples R China
关键词
feedback constraint optimization; nasopharyngeal carcinoma; radiation therapy; dose; MACHINE PARAMETER OPTIMIZATION; 2-STEP IMRT; NUMBER; IMAT;
D O I
10.3892/ol.2015.3523
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Intensity-modulated radiation therapy (IMRT) is able to achieve good target conformance with a limited dose to organs at risk (OARs); however, IMRT increases the irradiation volume and monitor units (MUs) required. The present study aimed to evaluate the use of an IMRT plan with fewer segments and MUs, while maintaining quality in the treatment of nasopharyngeal carcinoma. In the present study, two types of IMRT plan were therefore compared: The direct machine parameter optimization (DMPO)-RT method and the feedback constraint DMPO-RT (fc_DMPO-RT) method, which utilizes compensative feedback constraint in DMPO-RT and maintains optimization. Plans for 23 patients were developed with identical dose prescriptions. Each plan involved synchronous delivery to various targets, with identical OAR constraints, by means of 7 coplanar fields. The average dose, maximum dose, dose-volume histograms of targets and the OAR, MUs of the plan, the number of segments, delivery time and accuracy were subsequently compared. The fc_DMPO-RT exhibited superior dose distribution in terms of the average, maximum and minimum doses to the gross tumor volume compared with that of DMPO-RT (t=62.7, 20.5 and 22.0, respectively; P<0.05). The fc_DMPO-RT also resulted in a smaller maximum dose to the spinal cord (t=7.3; P<0.05), as well as fewer MUs, fewer segments and decreased treatment times than that of the DMPO-RT (t=6.2, 393.4 and 244.3, respectively; P<0.05). The fc_DMPO-RT maintained plan quality with fewer segments and MUs, and the treatment time was significantly reduced, thereby resulting in reduced radiation leakage and an enhanced curative effect. Therefore, introducing feedback constraint into DMPO may result in improved IMRT planning. In nasopharyngeal carcinoma specifically, feedback constraint resulted in the improved protection of OARs in proximity of targets (such as the brainstem and parotid) due to sharp dose distribution and reduced MUs.
引用
收藏
页码:2043 / 2050
页数:8
相关论文
共 50 条
  • [1] Intensity-modulated radiation therapy for nasopharyngeal carcinoma: a review
    Wang, Tony J. C.
    Riaz, Nadeem
    Cheng, Simon K.
    Lu, Jiade J.
    Lee, Nancy Y.
    JOURNAL OF RADIATION ONCOLOGY, 2012, 1 (02) : 129 - 146
  • [2] Skin sparing in intensity-modulated radiation therapy of nasopharyngeal carcinoma
    Baba, Misba Hamid
    Singh, Benoy K.
    Wani, Shaq ul Qamar
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (03) : 243 - 249
  • [3] Application of intensity-modulated radiation therapy in the treatment of nasopharyngeal carcinoma
    Yan, Hao
    Cao, Xiaoming
    Wang, Jinmei
    ONCOLOGY LETTERS, 2017, 14 (06) : 7773 - 7776
  • [4] A method for standardizing intensity modulated radiation therapy planning optimization for nasopharyngeal carcinoma
    Pang, H.
    Lin, S.
    Yang, B.
    Wu, J.
    Sun, X.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2019, 17 (01): : 177 - 181
  • [5] Volumetric intensity-modulated arc therapy vs conventional intensity-modulated radiation therapy in nasopharyngeal carcinoma: a dosimetric study
    White, Peter
    Chan, Kit Chi
    Cheng, Ka Wai
    Chan, Ka Yiu
    Chau, Ming Chun
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (03) : 532 - 545
  • [6] Intensity-Modulated Radiation Therapy in the Salvage of Locally Recurrent Nasopharyngeal Carcinoma
    Qiu, Sufang
    Lin, Shaojun
    Tham, Ivan W. K.
    Pan, Jianji
    Lu, Jun
    Lu, Jiade J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (02): : 676 - 683
  • [7] The current status of intensity-modulated radiation therapy in the treatment of nasopharyngeal carcinoma
    Lu, Heming
    Yao, Min
    CANCER TREATMENT REVIEWS, 2008, 34 (01) : 27 - 36
  • [8] Comparison of intensity-modulated proton therapy and intensity-modulated photon therapy in treatment of nasopharyngeal carcinoma
    Taheri-Kadkhoda, Z.
    Nill, S.
    Wilkens, J.
    Oelfke, U.
    Bjoerk-Eriksson, T.
    Huber, P.
    Munter, M. W.
    RADIOTHERAPY AND ONCOLOGY, 2007, 82 : S52 - S53
  • [9] Comparison of Intensity-Modulated Arc Therapy and Intensity-Modulated Radiotherapy Plans for Nasopharyngeal Carcinoma Simultaneously Integrated Boost Radiation Therapy
    Liu, T.
    Bai, T.
    Chen, J.
    Zhang, G.
    Ma, C.
    Yin, Y.
    Lin, X.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S563 - S563
  • [10] Comparison of Intensity-Modulated Arc Therapy and Intensity-Modulated Radiotherapy Plans for Nasopharyngeal Carcinoma Simultaneously Integrated Boost Radiation Therapy
    Liu, T.
    Yin, Y.
    Bai, T.
    Chen, J.
    Lu, J.
    Sun, T.
    Gao, M.
    Ma, C.
    MEDICAL PHYSICS, 2011, 38 (06)