Effects of 99mTc-MIBI and 99mTc-MDP administration on dual-energy X-ray absorptiometry bone mineral density measurements

被引:9
|
作者
Gumuser, Gul [1 ]
Parlak, Yasemin [1 ]
Topal, Gokcen [1 ]
Aras, Feray [1 ]
Ruksen, Ebru [1 ]
机构
[1] Celal Bayar Univ, Sch Med, Dept Nucl Med, TR-45030 Manisa, Turkey
关键词
Tc-99m-MDP; Tc-99m-MIBI; bone mineral density; dual-energy X-ray density; DIAGNOSIS; OSTEOPOROSIS; MANAGEMENT; GUIDELINES; PENCIL; BEAM; MDP;
D O I
10.1097/MNM.0b013e328329fc4c
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Nuclear medicine procedures are often performed in close-time proximity to bone densitometry studies. The purpose of this study was to determine the effects of Tc-99m-hexakis-2-methoxyisobutyl isonitrile (MIBI) and Tc-99m-methylene diphosphonate (MDP) on the accuracy of bone mineral density (BMD) measurements performed using dual-energy X-ray density. Methods The effect of a diagnostic dose of Tc-99m-MIBI on BMD estimations in the lumbar spine and the left total hip was assessed in 30 patients (19 female, 11 male; mean age: 55.5 +/- 10.5 years) by using a Lunar DPX-NT scanner. Thirty patients, admitted to the nuclear medicine department for bone scintigraphy (15 female, 15 male; mean age: 56 +/- 15.92 years), were included into the study. Each patient underwent dual-energy X-ray density assessment for which a Lunar DPX-NT scanner was used before and 2 h after intravenous injection of (99m)-Tc-MDP (925MBq) and Tc-99m-MIBI (1110MBq). BMD measurements were calculated from lumbar spine (including L2-4) and left hip (including femoral neck, trochanter, and total hip). For statistical analysis, the Wilcoxon test was used and a P value of less than 0.05 was accepted as statistically significant. Results According to Wilcoxon's statistical test, we found extremely significant changes on the measured BMD, T-score, before and 2 h after the injection of Tc-99m-MIBI for lumbar spine and left hip in 30 patients. We found statistically significant decrement on measured BMD from lumbar spine and trochanter before and 2 h after the injection of Tc-99m-MDP. Although MDP BMD values in femoral neck and total hip were decreased after the injection of Tc-99m, they did not reach a statistically significant value. The comparison of pre-T-score and post-T-score values showed a statistically significant decrease after the injection for only L2-4 lumbar spine (P=0.002), but left hip of pre-T-score and post-T-score values did not reach a statistically significant value. Conclusion In this study, it was determined that measured BMD values are decreased in lumbar spine for all patients. The magnitude of the effect is dependent on the location of the activity. We assume that some radioactivity from (TC)-T-99m is counted by the densitometer's detector, thus resulting in a decrease in the measured BMD. Scintigraphy and bone densitometry should be performed on different days to avoid artifactual reduction in BMD measurements. Nucl Med Commun 30:445-448 (C) 2009 Wolters Kluwer Health | Lippincott Williams & Wilkins.
引用
收藏
页码:445 / 448
页数:4
相关论文
共 50 条
  • [41] Lung and gastric uptake of 99mTc-MDP in bone scintigraphy in a patient with hypercalcemia induced by alfacalcidol administration
    Asakawa, H
    Onishi, M
    ENDOCRINOLOGIST, 2005, 15 (04): : 199 - 201
  • [42] 99mTc-MDP dual bone scan can predict 153Sm-EDTMP uptake
    Maffioli, L. S.
    Florimonte, L.
    Cammelli, F.
    Pagani, L.
    Vignati, A.
    Songini, C.
    Butti, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S350 - S350
  • [43] Study of mandible bone mineral density of Chinese adults by dual-energy X-ray absorptiometry
    Li, N.
    Jing, H.
    Li, J.
    Zhou, F.
    Bu, L.
    Yang, X.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 40 (11) : 1275 - 1279
  • [44] Anomalies in the measurement of changes in bone mineral density of the spine by dual-energy X-ray absorptiometry
    Tothill, P
    Avenell, A
    CALCIFIED TISSUE INTERNATIONAL, 1998, 63 (02) : 126 - 133
  • [45] Bone mineral and soft tissue measurements by dual-energy X-ray absorptiometry during growth
    Tothill, P
    Hannan, WJ
    BONE, 2002, 31 (04) : 492 - 496
  • [46] A physical model for dual-energy x-ray absorptiometry-derived bone mineral density
    Sievänen, H
    INVESTIGATIVE RADIOLOGY, 2000, 35 (05) : 325 - 330
  • [47] Anomalies in the Measurement of Changes in Bone Mineral Density of the Spine by Dual-Energy X-ray Absorptiometry
    P. Tothill
    A. Avenell
    Calcified Tissue International, 1998, 63 : 126 - 133
  • [48] Precision and accuracy of measuring changes in bone mineral density by dual-energy X-ray absorptiometry
    P. Tothill
    W. J. Hannan
    Osteoporosis International, 2007, 18 : 1515 - 1523
  • [49] The Effect of Abdominal Anatomy on the Measurement of Bone Mineral Density With Dual-Energy X-Ray Absorptiometry
    Basaloglu, Can
    Gungor, Ozlem
    Balci, Ali
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (03) : 458 - 462
  • [50] Does the Precision of Dual-Energy X-ray Absorptiometry for Bone Mineral Density Differ by Sex?
    Krueger, Diane
    Vallarta-Ast, Nellie
    Libber, Jessie
    Gangnon, Ronald
    Binkley, Neil
    JOURNAL OF CLINICAL DENSITOMETRY, 2014, 17 (04) : 505 - 509