Recommendations for dose calculations of lung cancer treatment plans treated with stereotactic ablative body radiotherapy (SABR)

被引:2
|
作者
Devpura, S. [1 ]
Siddiqui, M. S. [1 ]
Chen, D. [1 ]
Liu, D. [1 ]
Li, H. [1 ]
Kumar, S. [1 ]
Gordon, J. [1 ]
Ajlouni, M. [1 ]
Movsas, B. [1 ]
Chetty, I. J. [1 ]
机构
[1] Henry Ford Hlth Syst, Detroit, MI 48202 USA
关键词
MONTE-CARLO; RADIATION-THERAPY; PHOTON BEAMS; ALGORITHM; VMC;
D O I
10.1088/1742-6596/489/1/012007
中图分类号
O59 [应用物理学];
学科分类号
摘要
The purpose of this study was to systematically evaluate dose distributions computed with 5 different dose algorithms for patients with lung cancers treated using stereotactic ablative body radiotherapy (SABR). Treatment plans for 133 lung cancer patients, initially computed with a 1D-pencil beam (equivalent-path-length, EPL-1D) algorithm, were recalculated with 4 other algorithms commissioned for treatment planning, including 3-D pencil-beam (EPL-3D), anisotropic analytical algorithm (AAA), collapsed cone convolution superposition (CCC), and Monte Carlo (MC). The plan prescription dose was 48 Gy in 4 fractions normalized to the 95% isodose line. Tumors were classified according to location: peripheral tumors surrounded by lung (lung-island, N=39), peripheral tumors attached to the rib-cage or chest wall (lung-wall, N=44), and centrally-located tumors (lung-central, N=50). Relative to the EPL-1D algorithm, PTV D95 and mean dose values computed with the other 4 algorithms were lowest for "lung-island" tumors with smallest field sizes (3-5 cm). On the other hand, the smallest differences were noted for lung-central tumors treated with largest field widths (7-10 cm). Amongst all locations, dose distribution differences were most strongly correlated with tumor size for lung-island tumors. For most cases, convolution/superposition and MC algorithms were in good agreement. Mean lung dose (MLD) values computed with the EPL-1D algorithm were highly correlated with that of the other algorithms (correlation coefficient =0.99). The MLD values were found to be similar to 10% lower for small lung-island tumors with the model-based (conv/superposition and MC) vs. the correction-based (pencil-beam) algorithms with the model-based algorithms predicting greater low dose spread within the lungs. This study suggests that pencil beam algorithms should be avoided for lung SABR planning. For the most challenging cases, small tumors surrounded entirely by lung tissue (lung-island type), a Monte-Carlo-based algorithm may be warranted.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Factors affecting bony anatomy setup errors for lung Stereotactic Ablative Body Radiotherapy (SABR)
    Quinn, Emily
    Bennett, Erica
    Barry, Laura
    England, Andrew
    Devine, Annemarie
    McEntee, Mark
    O'Donovan, Theresa
    Kelly, Paul
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S5613 - S5615
  • [32] Small Lung Tumours: High Risk Lesions and Contraindications to Stereotactic Ablative Body Radiotherapy (SABR)
    Ball, D.
    JOURNAL OF THORACIC ONCOLOGY, 2018, 13 (10) : S225 - S226
  • [33] Does Histological Subtype Affect Outcomes in Stereotactic Ablative Body Radiotherapy (SABR) for Lung Tumors?
    Allos, B.
    Mascall, S.
    Vreugdenhil, M.
    Watkins, S.
    Stevenson, R.
    Ghafoor, Q.
    JOURNAL OF THORACIC ONCOLOGY, 2017, 12 (11) : S2179 - S2180
  • [34] Stereotactic body radiotherapy (SBRT)/stereotactic ablative body radiotherapy (SABR) for "radioresistant" renal cell carcinoma (RCC)
    Ishiyama, Hiromichi
    Blanco, Angel I.
    Lo, Simon S.
    Butler, E. Brian
    Teh, Bin S.
    JOURNAL OF RADIATION ONCOLOGY, 2014, 3 (04) : 339 - 346
  • [35] Stereotactic ablative body radiotherapy (SABR): Weston Park Hospital experience
    Das, T. S.
    Bates, E.
    Waweru, A.
    Fisher, P.
    Lee, C. E.
    Hatton, M.
    LUNG CANCER, 2016, 91 : S47 - S47
  • [36] Optimisation of stereotactic ablative body radiotherapy (SABR) planning: the Hull method
    Tambe, N. S.
    Colley, W. P.
    Beaumont, A. K. E.
    Beavis, A. W.
    LUNG CANCER, 2015, 87 : S47 - S48
  • [37] Effects of reconstruction methods on dose distribution for lung stereotactic body radiotherapy treatment plans
    Yagiz Yedekci
    Pervin Hurmuz
    Gökhan Ozyigit
    Radiation and Environmental Biophysics, 2023, 62 : 107 - 115
  • [38] Effects of reconstruction methods on dose distribution for lung stereotactic body radiotherapy treatment plans
    Yedekci, Yagiz
    Hurmuz, Pervin
    Ozyigit, Gokhan
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2023, 62 (01) : 107 - 115
  • [39] LATE OUTCOMES OF STEREOTACTIC ABLATIVE RADIOTHERAPY (SABR) FOR CENTRALLY LOCATED STAGE I LUNG CANCER
    Haasbeek, Cornelis J.
    Lagerwaard, Frank J.
    Slotman, Ben
    Senan, Suresh
    JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) : S542 - S543
  • [40] Retrospective study of intra-fractional motion in lung stereotactic ablative body radiotherapy (SABR) patients
    Liu, Baochang
    Matthews, Quinn
    Chng, Nick
    MEDICAL PHYSICS, 2019, 46 (11) : 5382 - 5382