The sensitivity and specificity of nonmydriatic digital stereoscopic retinal imaging in detecting diabetic retinopathy

被引:111
|
作者
Ahmed, Jehanara
Ward, Thomas P.
Bursell, Sven-Eric
Aiello, Lloyd M.
Cavallerano, Jerry D.
Vigersky, Robert A.
机构
[1] Walter Reed Army Med Ctr, Serv Endocrinol, Washington, DC 20307 USA
[2] Howard Univ Hosp, Div Endocrinol & Metab, Washington, DC USA
[3] Walter Reed Army Med Ctr, Ophthalmol Serv, Washington, DC 20307 USA
[4] Harvard Univ, Sch Med, Beetham Eye Inst, Joslin Diabet Ctr, Boston, MA 02115 USA
关键词
D O I
10.2337/dc06-0295
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - The objective of this study was to determine the sensitivity and specificity of Joslin Vision Network nonmydriatic digital stereoscopic retinal imaging (NMDSRI) as a screening tool in detecting diabetic retinopathy. RESEARCH DESIGN AND METHODS - We reviewed the records of 244 patients with diabetes who had a dilated funduscopic examination (DFE) and NMDSRI done within I year of each other at four locations in the metropolitan Washington, DC, area. The images were transmitted through a local area network to a central reading location where they were graded by a single retinal specialist. RESULTS - Images of 482 eyes from 243 patients were included in the study. Four images did not transmit, and 35% of the images were not gradable. Of the remaining 311 eyes, there was 86% agreement in the grading between NMDSRI and DFE: 227 eyes with no diabetic retinopathy and 40 eyes with diabetic retinopathy. In 46 eyes (15%) there was a disagreement between gradings made by the two techniques. NMDSRI detected diabetic retinopathy in 35 eyes reported as normal by DFE, and in the remaining II eyes, the DFE grade was one grade higher than the NMDSRI grade. Adjudicated nonconcordant examinations were within one grade. In the 76 eyes with diabetic retinopathy, retinal thickness could not be assessed in 17 (21%) eyes. When the NMDSRI result was gradable, the overall sensitivity of NMDSRI was 98% and the specificity was 100% for retinopathy within one grade of the DFE. In the limited number of eyes that had diabetic retinopathy with macular edema (six), agreement with the clinical examination was 100%. CONCLUSIONS - NMDSRI is a sensitive and specific method for the screening and diagnosis of diabetic retinopathy, which may help improve compliance with the standards of eye care for patients with diabetes.
引用
收藏
页码:2205 / 2209
页数:5
相关论文
共 50 条
  • [21] Screening for diabetic retinopathy: The utility of nonmydriatic retinal photography in Egyptian adults
    Penman, AD
    Saaddine, JB
    Hegazy, M
    Sous, ES
    Ali, MA
    Brechner, RJ
    Herman, WH
    Engelgau, MM
    Klein, R
    DIABETIC MEDICINE, 1998, 15 (09) : 783 - 787
  • [22] Comparison of nonmydriatic digital retinal imaging with dilated clinical eye exam for detecting non-diabetes-related pathology in diabetic patients
    Chow, SP
    Cavallerano, J
    Katalinic, P
    Hock, K
    Tolson, A
    Kirby, R
    Aiello, LM
    Aiello, LP
    Bursell, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U370 - U370
  • [23] Nonmydriatic widefield retinal imaging with an automatic white LED confocal imaging system compared with dilated ophthalmoscopy in screening for diabetic retinopathy
    Borrelli, Enrico
    Querques, Lea
    Lattanzio, Rosangela
    Cavalleri, Michele
    Moretti, Alessio Grazioli
    Di Biase, Carlo
    Signorino, Alberto
    Gelormini, Francesco
    Sacconi, Riccardo
    Bandello, Francesco
    Querques, Giuseppe
    ACTA DIABETOLOGICA, 2020, 57 (09) : 1043 - 1047
  • [24] Smartphone-based Nonmydriatic Fundus Imaging to Detect Diabetic Retinopathy
    Bhardwaj, Mahesh Kumar
    Stratton, Samuel
    Roh, Shiyoung
    Luna, Jorge
    Cotran, Paul R.
    Ramsey, David J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [25] Nonmydriatic widefield retinal imaging with an automatic white LED confocal imaging system compared with dilated ophthalmoscopy in screening for diabetic retinopathy
    Enrico Borrelli
    Lea Querques
    Rosangela Lattanzio
    Michele Cavalleri
    Alessio Grazioli Moretti
    Carlo Di Biase
    Alberto Signorino
    Francesco Gelormini
    Riccardo Sacconi
    Francesco Bandello
    Giuseppe Querques
    Acta Diabetologica, 2020, 57 : 1043 - 1047
  • [26] Use of a nonmydriatic retinal camera to screen for diabetic retinopathy in a primary care setting
    Gutierrez, M
    Jovanovic, L
    Pettitt, DJ
    ENDOCRINOLOGIST, 2001, 11 (05): : 384 - 387
  • [27] Nonmydriatic Widefield Retinal Imaging with an Automatic White Led Confocal Imaging System Compared with Dilated Ophthalmoscopy in Screening for Diabetic Retinopathy
    Querques, G.
    Borrelli, E.
    Querques, L.
    Lattanzio, R.
    Cavalleri, M.
    Sacconi, R.
    Bandello, F.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (1_SUPPL) : 21 - 21
  • [28] Evaluation of stereoscopic digital imaging to identify diabetic retinopathy via tele-ophthalmology.
    Tennant, MTS
    Greve, MDJ
    Rudnisky, CJ
    Hinz, BJ
    Hillson, TR
    MacDonald, IM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S648 - S648
  • [29] Identification of diabetic retinopathy by stereoscopic digital imaging via teleophthalmology: a comparison to slide film
    Tennant, MTS
    Greve, MDJ
    Rudnisky, CJ
    Hillson, TR
    Hinz, BJ
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2001, 36 (04): : 187 - 196
  • [30] Is digital retinal imaging atone sufficient as a screening tool for diabetic retinopathy?
    Razvi, FM
    Illahi, W
    Ryder, R
    DIABETES, 2000, 49 : A382 - A382