Detailed characterization of the kinetic performance of first and second generation silica monolithic columns for reversed-phase chromatography separations

被引:38
|
作者
Cabooter, Deirdre [1 ]
Broeckhoven, Ken [2 ]
Sterken, Roman [1 ]
Vanmessen, Alison [1 ]
Vandendael, Isabelle [3 ]
Nakanishi, Kazuki [4 ]
Deridder, Sander [2 ]
Desmet, Gert [2 ]
机构
[1] Katholieke Univ Leuven, Dept Pharmaceut Sci, B-3000 Louvain, Belgium
[2] Vrije Univ Brussel, Dept Chem Engn, B-1050 Brussels, Belgium
[3] Vrije Univ Brussel, Fac Engn Mat & Chem, B-1050 Brussels, Belgium
[4] Kyoto Univ, Dept Chem, Sakyo Ku, Kyoto 6058502, Japan
关键词
Second generation silica monoliths; Kinetic performance; Characteristic length; Flow resistance; TOTAL PORE BLOCKING; SOL-GEL SYSTEM; LIQUID-CHROMATOGRAPHY; DIFFUSION-COEFFICIENTS; EDDY DISPERSION; HIGH-PRESSURE; HPLC; EFFICIENCY; TERM; GENERATION;
D O I
10.1016/j.chroma.2013.11.047
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The kinetic performance of commercially available first generation and prototype second generation silica monoliths has been investigated for 2.0 mm and 3.0-3.2 mm inner diameter columns. It is demonstrated that the altered sol-gel process employed for the production of second generation monoliths results in structures with a smaller characteristic size leading to an improved peak shape and higher efficiencies. The permeability of the columns however, decreases significantly due to the smaller throughpore and skeleton sizes. Scanning electron microscopy pictures suggest the first generation monoliths have cylindrical skeleton branches, whereas the second generation monoliths rather have skeleton branches that resemble a single chain of spherical globules. Using recently established correlations for the flow resistance of cylindrical and globule chain type monolithic structures, it is demonstrated that the higher flow resistance of the second generation monoliths can be entirely attributed to their smaller skeleton sizes, which is also evident from the external porosity that is largely the same for both monolith generations (epsilon(e) similar to 0.65). The recorded van Deemter plots show a clear improvement in efficiency for the second generation monoliths (minimal plate heights of 13.6-14.1 mu m for the first and 6.5-8.2 mu m for the second generation, when assessing the plate count using the Foley-Dorsey method). The corresponding kinetic plots, however, indicate that the much reduced permeability of the second generation monoliths results in kinetic performances (time needed to achieve a given efficiency) which are only better than those of the first generation for plate counts up to N similar to 45,000. For more complex samples (N >= 50,000), the first generation monoliths can intrinsically still provide faster analysis due to their high permeability. It is also demonstrated that - despite the improved efficiency of the second generation monoliths in the practical range of separations (N = 10,000-50,000) - these columns can still not compete with state-of-the-art core-shell particle columns when all columns are evaluated at their own maximum operating pressure (200 bar for the monolithic columns, 600 bar for core-shell columns). It is suggested that monolithic columns will only become competitive with these high efficiency particle columns when further improvements to their production process are made and their pressure resistance is raised. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:72 / 82
页数:11
相关论文
共 50 条
  • [31] Excess isotherms as a new way for characterization of the columns for reversed-phase liquid chromatography
    Buszewski, B.
    Bocian, Sz.
    Felinger, A.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1191 (1-2) : 72 - 77
  • [32] Improved reversed-phase high performance liquid chromatography columns for biopharmaceutical analysis
    Ricker, RD
    Sandoval, LA
    Permar, BJ
    Boyes, BE
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 14 (1-2) : 93 - 105
  • [33] Serial coupled columns reversed-phase separations in high-performance liquid chromatography - Tool for analysis of complex real samples
    Herrero, Miguel
    Cacciola, Francesco
    Donato, Paola
    Giuffrida, Daniele
    Dugo, Giacomo
    Dugo, Paola
    Mondello, Luigi
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1188 (02) : 208 - 215
  • [34] PROTEIN SEPARATIONS ON REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY MINICOLUMNS
    MOORE, RM
    WALTERS, RR
    JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC): : 119 - 128
  • [35] Preparation of high efficiency and highly retentive monolithic silica capillary columns for reversed-phase chromatography by chemical modification by polymerization of octadecyl methacrylate
    Nunez, Oscar
    Ikegami, Tohru
    Kajiwara, Wataru
    Miyamoto, Kosuke
    Horie, Kanta
    Tanaka, Nobuo
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1156 (1-2) : 35 - 44
  • [36] Separation and characterization of octylphenol ethoxylate surfactants used by reversed-phase high-performance liquid chromatography on branched fluorinated silica gel columns
    Kamiusuki, T
    Monde, T
    Nemoto, F
    Konakahara, T
    Takahashi, Y
    JOURNAL OF CHROMATOGRAPHY A, 1999, 852 (02) : 475 - 485
  • [37] Separation of benzene and deuterated benzenes by reversed-phase and recycle liquid chromatography using monolithic capillary columns
    Lim, LW
    Uzu, H
    Takeuchi, T
    JOURNAL OF SEPARATION SCIENCE, 2004, 27 (15-16) : 1339 - 1344
  • [38] CHARACTERIZATION OF INTERNAL SURFACE REVERSED-PHASE SILICA SUPPORTS FOR LIQUID-CHROMATOGRAPHY
    COOK, SE
    PINKERTON, TC
    JOURNAL OF CHROMATOGRAPHY, 1986, 368 (02): : 233 - 248
  • [39] Thermodynamic and kinetic characterization of polycyclic aromatic hydrocarbons in reversed-phase liquid chromatography
    Howerton, SB
    McGuffin, VL
    ANALYTICAL CHEMISTRY, 2003, 75 (14) : 3539 - 3548
  • [40] Thermodynamic and kinetic characterization of porous graphitic carbon in reversed-phase liquid chromatography
    Zhang, Yuening
    McGuffin, Victoria L.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (9-12) : 1551 - 1575