Diagnostic value of quantitative contrast-enhanced ultrasound (CEUS) for early detection of renal hyperperfusion in diabetic kidney disease

被引:41
|
作者
Wang, Ling [1 ]
Wu, Jian [2 ]
Cheng, Jia-Fen [1 ]
Liu, Xin-Ying [1 ]
Ma, Fang [3 ]
Guo, Le-Hang [2 ]
Xu, Jun-Mei [2 ]
Wu, Tianfu [4 ]
Mohan, Chandra [4 ]
Peng, Ai [1 ]
Xu, Hui-Xiong [2 ]
Song, Ya-Xiang [1 ]
机构
[1] Tongji Univ, Shanghai Peoples Hosp 10, Dept Nephrol & Rheumatol, Shanghai 200072, Peoples R China
[2] Tongji Univ, Shanghai Peoples Hosp 10, Dept Ultrasound Med, Shanghai 200072, Peoples R China
[3] Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Dept Ultrasound, Shanghai 200030, Peoples R China
[4] Univ Houston, Dept Biomed Engn, Houston, TX 77204 USA
基金
中国国家自然科学基金;
关键词
Contrast-enhanced ultrasound; Renal perfusion; Diabetic kidney disease; GLOMERULAR-FILTRATION-RATE; SERUM URIC-ACID; ENDOTHELIAL DYSFUNCTION; BLOOD-FLOW; PROGRESSION; PERFUSION; INSULIN; ULTRASONOGRAPHY; NEPHROPATHY; PROTEINURIA;
D O I
10.1007/s40620-015-0183-3
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose To investigate the diagnostic value of quantitative contrast-enhanced ultrasound (CEUS) for early detection of renal hyperperfusion in diabetic kidney disease (DKD). Materials and methods 55 DKD patients with estimated glomerular filtration rate (eGFR) > 30 ml/min/1.73 m(2) and 26 normal controls (NCs) were enrolled. Clinical data was well documented. Blood samples were drawn for evaluation of renal function including blood urea nitrogen (BUN), serum creatinine (SCr) and serum uric acid (SUA), and urine samples were assayed for total protein quantification, and various microprotein markers. According to eGFR level, DKD patients were divided into early-stage DKD (eGFR a parts per thousand yen90 ml/min/1.73 m(2), n = 18) and middle-stage DKD (eGFR 30-90 ml/min/1.73 m(2), n = 37). Based on urinary microalbumin/creatinine ratio (MALB/UCR), early-stage DKD patients were further classified into two groups: MALB/UCR < 10 g/mol (n = 11) and MALB/UCR a parts per thousand yen10 g/mol (n = 7). Then, CEUS was performed to observe the real-time renal perfusion, and low acoustic power contrast-specific imaging was used for quantitative analysis. Results The renal perfusion images of CEUS were well developed successively. The corresponding perfusion curves based on echo-power signals in time series were constructed. Quantitative analysis showed that area under the descending curve (AUC2) was significantly increased in early-stage DKD compared to middle-stage DKD (p < 0.05), but AUC showed no significant difference. Further comparison between different MALB/UCR levels of early-stage DKD showed that patients with MALB/UCR a parts per thousand yen10 g/mol had significantly increased levels of AUC, AUC2 and proteinuria than patients with low MALB/UCR (p < 0.05). Also, high MALB/UCR DKD patients had increased proteinuria but similar eGFR compared to low MALB/UCR patients. Conclusion Renal microvascular hyperperfusion may be responsible for overt proteinuria until decline of renal filtration in DKD. AUC2 could be an early and sensitive marker for early renal injury and renal microvascular hyperperfusion in DKD.
引用
收藏
页码:669 / 678
页数:10
相关论文
共 50 条
  • [41] Value of contrast-enhanced ultrasound in rheumatic disease
    Klauser, AS
    EUROPEAN RADIOLOGY, 2005, 15 : E117 - E122
  • [42] Contrast-enhanced ultrasound (CEUS) imaging for active surveillance of small renal masses
    Bertelli, Elena
    Palombella, Alberto
    Sessa, Francesco
    Baldi, Irene
    Morelli, Noemi
    Verna, Silvia
    Greco, Isabella
    Morselli, Simone
    Pili, Alessandro
    Sebastianelli, Arcangelo
    Berni, Alessandro
    Nicoletti, Rossella
    Minervini, Andrea
    Carini, Marco
    Gacci, Mauro
    Miele, Vittorio
    Agostini, Simone
    Serni, Sergio
    Campi, Riccardo
    WORLD JOURNAL OF UROLOGY, 2021, 39 (08) : 2853 - 2860
  • [43] The current role of contrast-enhanced ultrasound (CEUS) imaging in the evaluation of renal pathology
    Salvatore Siracusano
    Michele Bertolotto
    Stefano Ciciliato
    Massimo Valentino
    Giovanni Liguori
    Francesco Visalli
    World Journal of Urology, 2011, 29
  • [44] Effect of iodinated contrast media on renal perfusion: A randomized comparison study in pigs using quantitative contrast-enhanced ultrasound (CEUS)
    Philipp Lamby
    Friedrich Jung
    Stefanie Graf
    Lotte Schellenberg
    Johannes Falter
    Natascha Platz-da-Silva
    Stephan Schreml
    Lukas Prantl
    Ralf P. Franke
    Ernst M. Jung
    Scientific Reports, 7
  • [45] CONTRAST-ENHANCED ULTRASOUND TO ASSESS RENAL MICROCIRCULATION IN PATIENTS WITH CHRONIC KIDNEY DISEASE
    Garessus, Jonas
    Brito, Wendy
    Loncle, Nicolas
    Vannelli, Anna
    Wuerzner, Gregoire
    Schneider, Antoine
    Pruijm, Menno
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2020, 35 : 998 - 998
  • [46] Effect of iodinated contrast media on renal perfusion: A randomized comparison study in pigs using quantitative contrast-enhanced ultrasound (CEUS)
    Lamby, Philipp
    Jung, Friedrich
    Graf, Stefanie
    Schellenberg, Lotte
    Falter, Johannes
    Platz-da-Silva, Natascha
    Schreml, Stephan
    Prantl, Lukas
    Franke, Ralf P.
    Jung, Ernst M.
    SCIENTIFIC REPORTS, 2017, 7
  • [47] Diagnostic value of pseudocapsule ring hyperenhancement in contrast-enhanced ultrasound in renal focal lesions
    Ligang Wang
    Hao Wu
    Jianchun Li
    Ying Wang
    Tingting Zhang
    Zhaowang Tan
    Yang Liu
    Han Wang
    Litao Sun
    Dong Xu
    Jianfeng Tu
    Irish Journal of Medical Science (1971 -), 2023, 192 : 1631 - 1636
  • [48] Diagnostic value of pseudocapsule ring hyperenhancement in contrast-enhanced ultrasound in renal focal lesions
    Wang, Ligang
    Wu, Hao
    Li, Jianchun
    Wang, Ying
    Zhang, Tingting
    Tan, Zhaowang
    Liu, Yang
    Wang, Han
    Sun, Litao
    Xu, Dong
    Tu, Jianfeng
    IRISH JOURNAL OF MEDICAL SCIENCE, 2023, 192 (04) : 1631 - 1636
  • [49] CONTRAST-ENHANCED ULTRASOUND (CEUS) IN DETECTION OF SESSILE BLADDER CARCINOMAS: PRELIMINARY DATA
    Lanzi, Federico
    Mazzei, Francesco
    Zumpano, Carmen
    Grisolia, Palmira
    Scipioni, Federica
    Tosi, Nicola
    Canale, Aude
    Pizzirusso, Gerardo
    Gentile, Filippo
    Cecconi, Filippo
    De Rubertis, Giovanni
    Barbanti, Gabriele
    Centra, Maria Antonietta
    ANTICANCER RESEARCH, 2014, 34 (05) : 2649 - 2650
  • [50] Tips and Tricks in Contrast-Enhanced Ultrasound (CEUS) for the Characterization and Detection of Liver Malignancies
    Schellhaas, Barbara
    Strobel, Deike
    ULTRASCHALL IN DER MEDIZIN, 2019, 40 (04): : 404 - 419