Radiation doses given during standard and complex interventional procedures were compared. Screening times, dose-area products, and radiologists' forehead and finger doses were recorded during 28 standard percutaneous drainages and 10 complex drainages (eight combined procedures and two failed procedures). The median screening times (8.75 min) and finger doses (84 mu Gy) during standard drainages were less than those during complex drainages (20.5 min, p = 0.0005 and 163 mu Gy, p = 0.0003). Dose-area products and forehead doses were also lower, but not significantly. Previously published series on radiation measurements lack data on complex procedures. This may bias the results, since combined and failed interventions, which are common, are associated with higher radiation exposure than are standard procedures.
引用
收藏
页码:296 / 298
页数:3
相关论文
共 50 条
  • [41] Order of Magnitude Reduction of Radiation Exposure in Fluoroscopically Guided Interventional Procedures
    Rowlands, J. A.
    Robert, N.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [42] Reduction of the radiation exposure of patients caused by selected interventional and angiographic procedures
    Seifert, H
    El-Jamal, A
    Roth, R
    Urbanczyk, K
    Kramann, B
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 1057 - 1064
  • [43] Radiation Dose Monitoring for Fluoroscopically Guided Interventional Procedures: Effect on Patient Radiation Exposure
    Liu, Bob
    Hirsch, Joshua A.
    Li, Xinhua
    Sheridan, Robert M.
    Rehani, Madan M.
    Zheng, Hui
    Rabinov, James D.
    RADIOLOGY, 2019, 290 (03) : 744 - 749
  • [44] Operator Radiation Dose Reduction During Fluoroscopic Interventional Procedures
    Nachiappan, Arun C.
    Horn, Gag L.
    Spann, Stephanie C.
    Mayo, Ray C.
    Wynne, David M.
    Archer, Benjamin R.
    Whigham, Cliff J.
    Hancock, John A.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2015, 12 (05) : 527 - 530
  • [45] Skin radiation dose is markedly increased during interventional procedures
    Gaxiola, E
    Hwang, E
    Vlietstra, RE
    Brenner, AS
    Ebersole, DG
    Browne, KF
    CIRCULATION, 1997, 96 (08) : 3296 - 3296
  • [46] RADIATION EXPOSURE OF PATIENTS AND OPERATORS DURING INTERVENTIONAL RADIOLOGY
    KRAHE, T
    EWEN, K
    LACKNER, K
    KOSTER, O
    NICOLAS, V
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1986, 145 (02): : 217 - 220
  • [47] Impact of collimation on radiation exposure during interventional electrophysiology
    Walters, Tomos E.
    Kistler, Peter M.
    Morton, Joseph B.
    Sparks, Paul B.
    Halloran, Karen
    Kalman, Jonathan M.
    EUROPACE, 2012, 14 (11): : 1670 - 1675
  • [48] Radiation Exposure During Invasive Cardiovascular Procedures: Portable Shielding Versus Standard Lead Aprons
    Noor, Husam A.
    Althawadi, Noof
    Noor, Zaina
    AlAnsari, Nouf
    Chachar, Tarique S.
    Al Raisi, Sara
    Yousif, Nooraldaem
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [49] Physicians' exposure to radiation during electrophysiology procedures
    Faroux, Laurent
    Daval, Charline
    Lesaffre, Francois
    Blanpain, Thierry
    Chabert, Jean-Pierre
    Martin, Angeline
    Guinot, Mathias
    Luconi, Nicolas
    Espinosa, Madeline
    Nazeyrollas, Pierre
    Tourneux, Christophe
    Metz, Damien
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2019, 55 (02) : 233 - 237
  • [50] Radiation exposure of patients during endourological procedures
    De Coninck, Vincent
    Mortiers, Xavier
    Hendrickx, Laura
    De Wachter, Stefan
    Traxer, Olivier
    Keller, Etienne X.
    WORLD JOURNAL OF UROLOGY, 2024, 42 (01)