Validation of ligands in macromolecular structures determined by X-ray crystallography

被引:44
|
作者
Smart, Oliver S. [1 ]
Horsky, Vladimir [2 ,3 ]
Gore, Swanand [1 ,5 ]
Varekova, Radka Svobodova [2 ,3 ]
Bendova, Veronika [2 ,3 ,4 ]
Kleywegt, Gerard J. [1 ]
Velankar, Sameer [1 ]
机构
[1] European Bioinformat Inst, Prot Data Bank Europe, European Mol Biol Lab, Wellcome Genome Campus, Cambridge CB10 1SD, England
[2] Masaryk Univ, Natl Ctr Biomol Res, Fac Sci, Kamenice 5, Brno 62500, Czech Republic
[3] Masaryk Univ, CEITEC Cent European Inst Technol, Kamenice 5, Brno 62500, Czech Republic
[4] Masaryk Univ, Inst Math & Stat, Kotlarska 2, CS-61137 Brno, Czech Republic
[5] 39 Earlham St, London WC2H 9LT, England
基金
英国惠康基金;
关键词
PDB; Protein Data Bank; three-dimensional macromolecular structure; validation; ligands; CRYSTAL-STRUCTURES; PROTEIN; REFINEMENT; VISUALIZATION; INFORMATION; REDUCTASE; FEATURES; PROGRAM; MODELS; ENERGY;
D O I
10.1107/S2059798318002541
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Crystallographic studies of ligands bound to biological macromolecules (proteins and nucleic acids) play a crucial role in structure-guided drug discovery and design, and also provide atomic level insights into the physical chemistry of complex formation between macromolecules and ligands. The quality with which small-molecule ligands have been modelled in Protein Data Bank (PDB) entries has been, and continues to be, a matter of concern for many investigators. Correctly interpreting whether electron density found in a binding site is compatible with the soaked or co-crystallized ligand or represents water or buffer molecules is often far from trivial. The Worldwide PDB validation report (VR) provides a mechanism to highlight any major issues concerning the quality of the data and the model at the time of deposition and annotation, so the depositors can fix issues, resulting in improved data quality. The ligand-validation methods used in the generation of the current VRs are described in detail, including an examination of the metrics to assess both geometry and electron-density fit. It is found that the LLDF score currently used to identify ligand electron-density fit outliers can give misleading results and that better ligand-validation metrics are required.
引用
收藏
页码:228 / 236
页数:9
相关论文
共 50 条
  • [41] PILATUS:: a two-dimensional X-ray detector for macromolecular crystallography
    Eikenberry, EF
    Brönnimann, C
    Hülsen, G
    Toyokawa, H
    Horisberger, R
    Schmitt, B
    Schulze-Briese, C
    Tomizaki, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 501 (01): : 260 - 266
  • [42] An evolutionary computational approach to the phase problem in macromolecular X-ray crystallography
    Webster, G
    Hilgenfeld, R
    ACTA CRYSTALLOGRAPHICA SECTION A, 2001, 57 : 351 - 358
  • [43] Solving large RNA structures by X-ray crystallography
    Cate, JH
    Doudna, JA
    RNA-LIGAND INTERACTIONS PT A: STRUCTURAL BIOLOGY METHODS, 2000, 317 : 169 - 180
  • [44] Solving modulated structures by X-ray and electron crystallography
    Caldes, MT
    Deniard, P
    Zou, XD
    Marchand, R
    Diot, N
    Brec, R
    MICRON, 2001, 32 (05) : 497 - 507
  • [45] X-RAY-DETECTORS FOR MACROMOLECULAR CRYSTALLOGRAPHY
    GRUNER, SM
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 1994, 4 (05) : 765 - 769
  • [46] X-RAY CRYSTALLOGRAPHY
    BRAGG, L
    SCIENTIFIC AMERICAN, 1968, 219 (01) : 58 - &
  • [47] X-RAY CRYSTALLOGRAPHY
    KILBOURN, BT
    CHEMISTRY & INDUSTRY, 1970, (03) : 75 - &
  • [48] X-ray crystallography
    Bombicz, Petra
    CRYSTALLOGRAPHY REVIEWS, 2016, 22 (01) : 79 - 81
  • [49] X-RAY CRYSTALLOGRAPHY
    DOUGLAS, AMB
    KELLAR, JN
    NATURE, 1947, 160 (4053) : 29 - 31
  • [50] Methods for X-ray diffraction analysis of macromolecular structures
    Beauchamp, JC
    Isaacs, NW
    CURRENT OPINION IN CHEMICAL BIOLOGY, 1999, 3 (05) : 525 - 529