Stereoscopic 3D CT vs standard 3D CT in the classification of acetabular fractures: an experimental study

被引:9
|
作者
Kickuth, R
Hartung, G
Laufer, U
Gruening, C
Stueckle, C
Liermann, D
Kirchner, J
机构
[1] Ruhr Univ Bochum, Marienhosp Herne, Dept Radiol, D-44625 Herne, Germany
[2] Ruhr Univ Bochum, Marienhosp Herne, Dept Surg, D-44625 Herne, Germany
来源
BRITISH JOURNAL OF RADIOLOGY | 2002年 / 75卷 / 893期
关键词
D O I
10.1259/bjr.75.893.750422
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The accuracy of stereoscopic and standard three-dimensional (3D) CT in the classification of acetabular fractures was compared. A receiver operating characteristic (ROC) analysis was performed by two radiologists and two surgeons blinded to the presence of acetabular fractures in an animal model (, a total of 62 porcine hips, 40 with artificial acetabular fractures). Classification of acetabular fractures was adopted from the literature. Interpretation was performed on a workstation using two specific volume rendering algorithms; unshaded and shaded bone. The ROC analysis did not demonstrate any benefit in stereoscopic 3D CT compared with standard 3D CT.
引用
收藏
页码:422 / 427
页数:6
相关论文
共 50 条
  • [31] Diagnostic value of 3D CT surface reconstruction in spinal fractures
    Kosling, S
    Dietrich, K
    Steinecke, R
    Kloppel, R
    Schulz, HG
    [J]. EUROPEAN RADIOLOGY, 1997, 7 (01) : 61 - 64
  • [32] The usefulness of spatial 3D CT imaging in diagnostics of axial fractures
    Krupski, W
    Majcher, P
    Paslawski, M
    Nogalski, A
    Krupski, M
    Fatyga, M
    Zlomaniec, J
    [J]. PROCEEDINGS OF THE 23RD INTERNATIONAL CONGRESS OF RADIOLOGY OF THE INTERNATIONAL SOCIETY OF RADIOLOGY, 2004, : 571 - 577
  • [33] Video Stabilization for Stereoscopic 3D on 3D Mobile Devices
    Chu, Chung-Hua
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA AND EXPO (ICME), 2014,
  • [34] Measurement of acetabular version based on biplanar radiographs with 3D reconstructions in comparison to CT as reference standard in cadavers
    Agten, Christoph A.
    Jonczy, Maciej
    Ullrich, Oliver
    Pfirrmann, Christian W. A.
    Sutter, Reto
    Buck, Florian M.
    [J]. CLINICAL ANATOMY, 2017, 30 (05) : 591 - 598
  • [35] Sound and stereoscopic 3D: Examining the effects of sound on depth perception in stereoscopic 3D
    Cullen, Brian
    Collins, Karen
    Hogue, Andrew
    Kapralos, Bill
    [J]. 2016 7TH INTERNATIONAL CONFERENCE ON INFORMATION, INTELLIGENCE, SYSTEMS & APPLICATIONS (IISA), 2016,
  • [36] 3D pulmonary CT image registration with a standard lung atlas
    Zhang, L
    Reinhardt, JM
    [J]. MEDICAL IMAGING 2000: PHYSIOLOGY AND FUNCTION FORM MULTIDIMENSIONAL IMAGES, 2000, 3978 : 67 - 77
  • [37] The Value of 3D Printed Models in Understanding Acetabular Fractures
    Brouwers, Lars
    ter Gunne, Albert F. Pull
    de Jongh, Mariska A. C.
    van der Heijden, Frank H. W. M.
    Leenen, Luke P. H.
    Spanjersberg, Willem R.
    van Helden, Sven H.
    Verbeek, Diederik O.
    Bemelman, Mike
    Lansink, Koen W. W.
    [J]. 3D PRINTING AND ADDITIVE MANUFACTURING, 2018, 5 (01) : 37 - 45
  • [38] Time efficiency of CT colonography: 2D vs 3D visualization
    Neri, Emanuele
    Vannozzi, Francesca
    Vagli, Paola
    Bardine, Alex
    Bartolozzi, Carlo
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2006, 30 (03) : 175 - 180
  • [39] Role of 3D printing in the management of complex acetabular fractures: a comparative study
    Ansari, Sajid
    Barik, Sitanshu
    Singh, Sanny Kumar
    Sarkar, Bhaskar
    Goyal, Tarun
    Kalia, Roop Bhushan
    [J]. EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2021, 47 (05) : 1291 - 1296
  • [40] Role of 3D printing in the management of complex acetabular fractures: a comparative study
    Sajid Ansari
    Sitanshu Barik
    Sanny Kumar Singh
    Bhaskar Sarkar
    Tarun Goyal
    Roop Bhushan Kalia
    [J]. European Journal of Trauma and Emergency Surgery, 2021, 47 : 1291 - 1296