Stereoscopic 3D CT vs standard 3D CT in the classification of acetabular fractures: an experimental study

被引:9
|
作者
Kickuth, R
Hartung, G
Laufer, U
Gruening, C
Stueckle, C
Liermann, D
Kirchner, J
机构
[1] Ruhr Univ Bochum, Marienhosp Herne, Dept Radiol, D-44625 Herne, Germany
[2] Ruhr Univ Bochum, Marienhosp Herne, Dept Surg, D-44625 Herne, Germany
来源
BRITISH JOURNAL OF RADIOLOGY | 2002年 / 75卷 / 893期
关键词
D O I
10.1259/bjr.75.893.750422
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The accuracy of stereoscopic and standard three-dimensional (3D) CT in the classification of acetabular fractures was compared. A receiver operating characteristic (ROC) analysis was performed by two radiologists and two surgeons blinded to the presence of acetabular fractures in an animal model (, a total of 62 porcine hips, 40 with artificial acetabular fractures). Classification of acetabular fractures was adopted from the literature. Interpretation was performed on a workstation using two specific volume rendering algorithms; unshaded and shaded bone. The ROC analysis did not demonstrate any benefit in stereoscopic 3D CT compared with standard 3D CT.
引用
收藏
页码:422 / 427
页数:6
相关论文
共 50 条
  • [1] Multiplanar and 3D CT of acetabular fractures
    Haveri, M
    Junila, J
    Suramo, I
    Lähde, S
    [J]. ACTA RADIOLOGICA, 1998, 39 (03) : 257 - 264
  • [2] THE ROLE OF 3D CT IN THE ASSESSMENT OF ACETABULAR FRACTURES
    GUY, RL
    BUTLERMANUEL, PA
    HOLDER, P
    BRUETON, RN
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (773): : 384 - 389
  • [3] 3D CT versus axial helical CT versus conventional tomography in the classification of acetabular fractures: A ROC analysis
    Kickuth, R
    Laufer, U
    Hartung, G
    Gruening, C
    Stueckle, C
    Kirchner, J
    [J]. CLINICAL RADIOLOGY, 2002, 57 (02) : 140 - 145
  • [4] Acetabular Fractures: What Radiologists Should Know and How 3D CT Can Aid Classification
    Scheinfeld, Meir H.
    Dym, Akiva A.
    Spektor, Michael
    Avery, Laura L.
    Dym, R. Joshua
    Amanatullah, Derek F.
    [J]. RADIOGRAPHICS, 2015, 35 (02) : 555 - 577
  • [5] STANDARD CT GUIDED 3D MODELS
    YANO, H
    ARAKAKI, M
    HIRANO, A
    [J]. BRITISH JOURNAL OF PLASTIC SURGERY, 1994, 47 (05): : 388 - 388
  • [6] Classification of acetabular fractures: 3D-CT vs axial helical CT vs conventional tomography: A ROC analysis
    Kickuth, R
    Kirchner, JK
    Hartung, G
    Gruening, M
    Stueckle, CA
    Liermann, DD
    [J]. RADIOLOGY, 2000, 217 : 409 - 409
  • [7] A simple device for the stereoscopic display of 3D CT images
    Haveri, M
    Suramo, I
    Junila, J
    Lahde, S
    Karhula, V
    [J]. ACTA RADIOLOGICA, 1997, 38 (06) : 1053 - 1056
  • [8] Review of Acetabular Fracture Classification Using 3D Volume-Rendered CT
    Cheekatla, S.
    West, C.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [9] Value of 3D fluoroscopic imaging of acetabular fractures comparison to 2D fluoroscopy and CT imaging
    D. Kendoff
    M. J. Gardner
    M. Citak
    M. Kfuri
    B. Thumes
    C. Krettek
    T. Hüfner
    [J]. Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 599 - 605
  • [10] Value of 3D fluoroscopic imaging of acetabular fractures comparison to 2D fluoroscopy and CT imaging
    Kendoff, D.
    Gardner, M. J.
    Citak, M.
    Kfuri, M., Jr.
    Thumes, B.
    Krettek, C.
    Huefner, T.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (06) : 599 - 605