Electromagnetic Analysis and Electrical Signature-Based Detection of Rotor Inter-Turn Faults in Salient-Pole Synchronous Machine

被引:24
|
作者
Valavi, Mostafa [1 ]
Jorstad, Kari Gjerde [1 ]
Nysveen, Arne [1 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Elect Power Engn, N-7034 Trondheim, Norway
关键词
Electrical signature analysis; hydrogenerators; inter-turn faults; online condition monitoring; radial forces; DIAGNOSIS;
D O I
10.1109/TMAG.2018.2854670
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, rotor inter-turn faults in salient-pole synchronous machines are investigated using finite-element analysis. The machine under study is a 22 MVA eight-pole hydropower generator with fractional-slot windings. Simulated faulty cases include 1, 2, 5, 10, and 20 short-circuited turns (out of 58 turns) in one rotor pole. In the electromagnetic analysis, the effect of faults on airgap flux density and radial forces is studied. Furthermore, this paper investigates online detection of inter-turn faults using spectral analysis of stator voltage or current is studied. The amplitude of fault-related harmonics is investigated at various fault severities, as well as at no-load and full-load operations. This paper also discusses the effects of damper bars, an influence of parallel circuits in the stator windings, and influence of the pole pair number. In addition, a comparison between fault-related harmonics in the case of dynamic eccentricity and rotor inter-turn faults is presented.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Detection and Discrimination of Simultaneous Stator Inter-Turn and Broken Rotor Bar Faults in Induction Motor
    Sonje, Deepak M.
    Kundu, P.
    Chowdhury, A.
    2015 INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON), 2015, : 133 - 138
  • [42] A Disassembly-Free Offline Detection and Condition Monitoring Technique for Eccentricity Faults in Salient-Pole Synchronous Machines
    Ilamparithi, T.
    Nandi, Subhasis
    Subramanian, Jayaram
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (02) : 1505 - 1515
  • [43] ANALYSIS OF TRANSIENTS IN A SALIENT-POLE SYNCHRONOUS MACHINE EXCITED FROM AN ADDITIONAL STATOR WINDING.
    Glukhivskii, L.I.
    Malyar, V.S.
    1600,
  • [44] Detection and Discrimination of Inter-Turn Short Circuit and Demagnetization Faults in PMSMs Based on Structural Analysis
    Ebrahimi, Saeed Hasan
    Choux, Martin
    Huynh, Van Khang
    2021 22ND IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2021, : 184 - 189
  • [45] Detection of Rotor Field Winding, Damper Bar, and Eccentricity Faults in Salient Pole Synchronous Machines With the Pole Drop Test
    Hansika, Thotahage Sumadhurie
    Shaikh, Muhammad Faizan
    Kim, Han-ju
    Lee, Sang Bin
    Orviz, Marcos
    Platero, Carlos A.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2023, 38 (03) : 2169 - 2178
  • [46] An Approach for On-Line Electrical Machine Winding Inter-turn Fault Detection
    Zhang, M. Q.
    Tseng, K. J.
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [47] MAGNETIC FIELD OF ARMATURE IN GAP OF A SOLID-ROTOR SALIENT-POLE SYNCHRONOUS MACHINE IN OUT-OF-STEP CONDITIONS
    VAZHNOV, AI
    ELECTRICAL TECHNOLOGY, 1969, 4 : 120 - &
  • [48] Comparison Between the Salient-Pole Synchronous Machine and the Doubly Fed Induction Machine With Regard to Electromagnetic Parasitic Forces and Stator Vibrations
    Lugand, Thomas
    Schwery, Alexander
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (06) : 5284 - 5294
  • [49] Torque Ripple Reduction of a Salient-Pole Permanent Magnet Synchronous Machine With an Advanced Step-Skewed Rotor Design
    Chen, Wei
    Ma, Jien
    Wu, Guichu
    Fang, Youtong
    IEEE ACCESS, 2020, 8 (08): : 118989 - 118999
  • [50] Steady-state analysis of inter-turn winding faults in a permanent magnet synchronous motor
    Alvarez-Salas, J. A.
    Peralta-Sanchez, E.
    Hernandez-Robles, I. A.
    Alvarez-Salas, R.
    2015 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2015,