Electromagnetic Analysis and Electrical Signature-Based Detection of Rotor Inter-Turn Faults in Salient-Pole Synchronous Machine

被引:24
|
作者
Valavi, Mostafa [1 ]
Jorstad, Kari Gjerde [1 ]
Nysveen, Arne [1 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Elect Power Engn, N-7034 Trondheim, Norway
关键词
Electrical signature analysis; hydrogenerators; inter-turn faults; online condition monitoring; radial forces; DIAGNOSIS;
D O I
10.1109/TMAG.2018.2854670
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, rotor inter-turn faults in salient-pole synchronous machines are investigated using finite-element analysis. The machine under study is a 22 MVA eight-pole hydropower generator with fractional-slot windings. Simulated faulty cases include 1, 2, 5, 10, and 20 short-circuited turns (out of 58 turns) in one rotor pole. In the electromagnetic analysis, the effect of faults on airgap flux density and radial forces is studied. Furthermore, this paper investigates online detection of inter-turn faults using spectral analysis of stator voltage or current is studied. The amplitude of fault-related harmonics is investigated at various fault severities, as well as at no-load and full-load operations. This paper also discusses the effects of damper bars, an influence of parallel circuits in the stator windings, and influence of the pole pair number. In addition, a comparison between fault-related harmonics in the case of dynamic eccentricity and rotor inter-turn faults is presented.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Research on the internal faults of the salient-pole synchronous machine
    Bei, OY
    Wang, XH
    Sun, YG
    Wang, WJ
    Wang, WH
    IPEMC 2000: THIRD INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, PROCEEDINGS, 2000, : 558 - 563
  • [2] Electromagnetic torque components in the synchronous salient-pole machine
    Spalek, D
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 1997, 16 (03) : 129 - +
  • [3] Analytical calculations of electromagnetic quantities for wound rotor salient-pole synchronous machines
    Delirani, Zohreh
    Rahideh, Akbar
    Mardaneh, Mohammad
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2021, 40 (03) : 325 - 357
  • [4] Analysis of impact of rotor winding inter-turn short circuit faults on electromagnetic torque
    Wan, Shu-Ting
    Zhang, Yu
    Hu, Yuan-Yuan
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2012, 16 (08): : 17 - 22
  • [5] Non-invasive Detection of Winding Short-circuit Faults in Salient-pole Synchronous Machine
    Cuevas, Mauricio
    Romary, Raphael
    Lecointe, Jean-Philippe
    Morganti, Fabrice
    Jacq, Thierry
    2017 IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE (IEMDC), 2017,
  • [6] Decoupled control of rotor torque and rotor electric power delivered in a salient-pole, synchronous machine
    Masoud, MI
    Fletcher, JE
    Williams, BW
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (01) : 45 - 52
  • [7] DETECTION OF SYNCHRONOUS MOTOR INTER-TURN FAULTS BASED ON SPECTRAL ANALYSIS OF PARK'S VECTOR
    Glowacz, Z.
    Kozik, J.
    ARCHIVES OF METALLURGY AND MATERIALS, 2013, 58 (01) : 19 - 23
  • [8] NEW PRINCIPLE FOR SYNCHRONOUS MACHINE PROTECTION FROM ROTOR WINDING INTER-TURN AND DOUBLE EARTH FAULTS
    KHRYUKIN, SS
    ELECTRICAL TECHNOLOGY, 1972, 2 : 47 - 59
  • [9] Rotor speed signature analysis-based inter-turn short circuit fault detection for permanent magnet synchronous machines
    Wei, Dong
    Liu, Kan
    Zhu, Zi-Qiang
    Zhou, Shichao
    Wang, Jianbo
    Chen, Yongdan
    IET ELECTRIC POWER APPLICATIONS, 2024, 18 (10) : 1187 - 1199
  • [10] Sensitivity Analysis of the Dynamic Behavior of a Salient-Pole Synchronous Machine Considering the Static Rotor Eccentricity Effect
    Albino Padilla, I.
    Olguin Salinas, D.
    Roman Messina, A.
    JOURNAL OF APPLIED RESEARCH AND TECHNOLOGY, 2012, 10 : 724 - 730