Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters

被引:1
|
作者
De Deene, Y [1 ]
Venning, A
Hurley, C
Healy, BJ
Baldock, C
机构
[1] Queensland Univ Technol, Ctr Med Hlth & Environm Phys, Brisbane, Qld, Australia
[2] QRI Mater Ctr, Brisbane, Qld, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2002年 / 47卷 / 14期
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study the stability of different polymer gel dosimeters is investigated. Further to a previous chemical stability study on a (6%T, 50%C) PAG gel, the change in slope and intercept of the linear part of the R2-dose plot is recorded with time for different gel formulations. In addition to this R2-dose-response stability study, the dose edge of a half-blocked field was recorded with time. Three different PAG type polymer gels, a hydroxyethyl acrylate (HEA) gel and two different normoxic polymer gets were investigated. In the PAG type polymer gels, the relative concentration of gelatin and comonomers was varied in order to study the influence of the different components, that constitute the dosimeter, on the stability. It is shown that the R2-dose-response stability is largely determined by the chemical composition of the gel dosimeters. All the PAG gel dosimeters and the normoxic gel dosimeters are found to preserve the integrity of the dose distribution up to 22 days after irradiation. The half-life of the change in dose sensitivity of a MAGIC gel is found to be 18 h compared to 5.7 h for a (6%T, 50%C) PAG gel. A maximum relative decrease in dose sensitivity of 21 % was noted for the MAGIC gel compared to an increase of 50% for a (6%T, 50%C) PAG gel. A loss of integrity of the dose distribution was found in the HEA gel.
引用
收藏
页码:2459 / 2470
页数:12
相关论文
共 50 条
  • [21] Effect of inorganic salts and glucose additives on dose-response, melting point and mass density of genipin gel dosimeters
    Al-Jarrah, A. M.
    Rahman, Azhar Abdul
    Shahrim, Iskandar
    Ab Razak, Nik Noor Ashikin Nik
    Ababneh, Baker
    Tousi, Ehsan Taghizadeh
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01): : 36 - 41
  • [22] An experimental study of the dose response of polymer gel dosimeters imaged with x-ray computed tomography
    Trapp, JV
    Bäck, SÅJ
    Lepage, M
    Michael, G
    Baldock, C
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (11): : 2939 - 2951
  • [23] FILM DOSIMETRY - LINEARIZATION OF DOSE-RESPONSE FOR RELATIVE MEASUREMENTS OF DOSE DISTRIBUTION
    MOTA, HC
    SIBATA, CH
    ROBERTS, W
    HIGGINS, PD
    PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (04): : 565 - 569
  • [24] Imaging dose: Calibration of polymer gel dosimeters for use in targeted radionuclide therapy
    Gear, Jonathan I.
    Flux, Glenn D.
    Charles-Edwards, Elizabeth
    Partridge, Mike
    Cook, Gary
    Ott, Robert J.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2664 - 2668
  • [25] The effect of x-ray CT dose on normoxic polymer gel dosimeters
    Baxter, P.
    Jirasek, A.
    Hilts, M.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S56 - S56
  • [26] Evaluation of the dose distribution of tomotherapy using polymer gel dosimeters and optical computed tomography with ring artifact correction
    Chou, Ying-Hsiang
    Lu, Yu-Chan
    Peng, Shin-Lei
    Lee, Shan-Chih
    Hsieh, Ling-Ling
    Shih, Cheng-Ting
    RADIATION PHYSICS AND CHEMISTRY, 2020, 168
  • [27] DOSE-RESPONSE AND DOSE INTENSITY REVISITED
    KERR, IG
    JOURNAL OF CLINICAL ONCOLOGY, 1986, 4 (12) : 1865 - 1866
  • [28] Stability of cocaine dose-response functions at different inter-dose intervals
    Marusich, Julie A.
    Branch, Marc N.
    PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 2006, 84 (02) : 360 - 369
  • [29] Response modification in polymer gel dosimeters
    Maryanski, M
    MEDICAL PHYSICS, 2002, 29 (06) : 1209 - 1209
  • [30] Dose sensitivity modification in polymer gel dosimeters improves the accuracy of optical CT scanning for gel dosimetry
    Maryanski, MJ
    Xu, Y
    Wuu, CS
    MEDICAL PHYSICS, 2003, 30 (06) : 1478 - 1478