RAPID DETERMINATION OF POLYCHLORINATED BIPHENYLS IN SOIL USING DIRECT THERMAL DESORPTION-GAS CHROMATOGRAPHY WITH NOVEL μ-VIAL INSERTION

被引:0
|
作者
Lv, Chun-Xin [1 ,2 ]
Li, Jia-Lu [1 ,2 ]
Gao, Song [1 ,2 ]
Zhang, Lan-Ying [1 ,2 ]
Wang, Lin [3 ]
Liu, Yuan-Yuan [1 ,2 ]
Pang, Ying-Ming [4 ]
机构
[1] Jilin Univ, Coll Environm & Resources, Changchun 130021, Peoples R China
[2] Jilin Univ, Minist Educ, Key Lab Groundwater Resources & Environm, Changchun 130021, Peoples R China
[3] Datang Jilin Power Generat Co Ltd, Changchun 130021, Peoples R China
[4] Focus Technol Co Ltd, Shanghai 200233, Peoples R China
来源
FRESENIUS ENVIRONMENTAL BULLETIN | 2015年 / 24卷 / 10A期
关键词
Direct thermal desorption; PCBs; Soil; mu-vial; ACCELERATED SOLVENT-EXTRACTION; MASS-SPECTROMETRY; PARTICULATE MATTER; FLUID EXTRACTION; GC-MS; VOLATILES; SEDIMENTS; GC/MS; IDENTIFICATION; SOXHLET;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this work was to develop a solvent-free extraction technique coupled with gas chromatography to quantitatively determine polychlorinated biphenyls (PCBs) in soil samples; thus, direct thermal desorption-gas chromatography (DTD-GC) was used. A small container of quartz deactivated by silanization, named the mu-vial, was developed for thermal desorption of solid samples. The novel mu-vial was inserted into the liner to load the solid sample. The insertion method can affect thermal desorption and transference from vaporizing chamber to the column. A comparison between four mu-vials (b, c, d, and e) that are used to determine PCBs using DTD-GC showed that the d-shaped mu-vial with a side hole enhanced analysis sensitivity and reliability. Experimental analysis revealed the main methodologies required to determine 17 PCBs using DTD-GC, which are summarized as follows: a spiked soil sample (50 ng g(-1) and 200 ng g(-1)) with a particle size of 250 gm, the method detection limits (MDLs) of 2.89-9.69 mu g kg(-1) (relative standard deviation RSD<7.86%), and a recovery of 72.5% to 104.2%; a desorption temperature of 450 degrees C; a desorption time of 120 s; and a transfer time to head column of 90 s. A test of real environmental samples demonstrated that the results using DTD-GC were similar to those obtained by EPA8082.
引用
收藏
页码:3381 / 3389
页数:9
相关论文
共 50 条
  • [41] Determination of selected polychlorinated biphenyls in soil and earthworm (Eisenia fetida) using a QuEChERS-based method and gas chromatography with tandem MS
    He, Zeying
    Wang, Lu
    Peng, Yi
    Luo, Ming
    Wang, Wenwen
    Liu, Xiaowei
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (21) : 3766 - 3773
  • [42] Development of a method based on thermal desorption-gas chromatography/mass spectrometry for the determination of 103 volatile organic compounds in mattresses
    Cao, Shurui
    Wen, Yao
    Xi, Cunxian
    Li, Xianliang
    Zhang, Lei
    Wang, Guomin
    Shang, Jingchuan
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2020, 100 (09) : 1044 - 1065
  • [43] DETERMINATION OF POLYCHLORINATED-BIPHENYLS USING LIMITED MASS SCAN GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    WESTERBERG, RB
    ALIBRANDO, SL
    VANLENTEN, FJ
    JOURNAL OF CHROMATOGRAPHY, 1984, 284 (02): : 447 - 456
  • [44] Investigation of characterization method for nanoparticles in roadside atmosphere by thermal desorption-gas chromatography/mass spectrometry using a pyrolyzer
    Fushimi, Akihiro
    Tanabe, Kiyoshi
    Hasegawa, Shuichi
    Kobayashi, Shinji
    SCIENCE OF THE TOTAL ENVIRONMENT, 2007, 386 (1-3) : 83 - 92
  • [45] Determination of Polycyclic Aromatic Hydrocarbons in Dianchi Lake Using Stir Bar Sorptive Extraction-Thermal Desorption-Gas Chromatography/Mass Spectrometry
    Yang Lei
    Wang Baoxing
    Hou Ying
    Yang Yan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2007, 25 (05) : 747 - 752
  • [46] Rapid and sensitive determination of morphine in street opium samples by thermal desorption gas chromatography using a microfurnace pyrolyzer
    Hida, M
    Mitsui, T
    Tsuge, S
    Ohtani, H
    JOURNAL OF SEPARATION SCIENCE, 2004, 27 (12) : 1030 - 1032
  • [47] Measuring aliphatic hydrocarbons in sediments by direct thermal desorption-gas chromatography-mass spectrometry: Matrix effects and quantification challenges
    Portet-Koltalo, Florence
    Humbert, Kevin
    Cosme, Julie
    Debret, Maxime
    Morin, Christophe
    Le Gohlisse, Steeven
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1722
  • [48] Solvent-free automated thermal desorption-gas chromatography/mass spectrometry for direct screening of hazardous compounds in consumer textiles
    Josefine Carlsson
    Tim Åström
    Conny Östman
    Ulrika Nilsson
    Analytical and Bioanalytical Chemistry, 2023, 415 : 4675 - 4687
  • [49] Determination of selected polychlorinated biphenyls in soil by miniaturised ultrasonic solvent extraction and gas chromatography-mass-selective detection
    Aydin, Mehmet Emin
    Tor, Ali
    Ozcan, Senar
    ANALYTICA CHIMICA ACTA, 2006, 577 (02) : 232 - 237
  • [50] Solvent-free automated thermal desorption-gas chromatography/mass spectrometry for direct screening of hazardous compounds in consumer textiles
    Carlsson, Josefine
    Astrom, Tim
    Ostman, Conny
    Nilsson, Ulrika
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (19) : 4675 - 4687