Metrology in the Soft X-Ray Range - from EUV to the Water Window

被引:4
|
作者
Laubis, Christian [1 ]
Scholze, Frank [1 ]
Ulm, Gerhard [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
来源
关键词
metrology; calibration; soft X-ray; EUV; water window; detection efficiency; reflectometry; scatterometry;
D O I
10.1117/12.797721
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Metrology in the soft X-ray range has various applications ranging from instrumentation for solar astronomy to plasma experiments and EUV Lithography. The Physikalisch-Technische Bundesanstalt (PTB) with its laboratory at the electron storage ring BESSY II is a centre of soft X-ray radiometry and supports national and European research and development by carrying out high-accuracy at-wavelength measurements. The absolute detection efficiency of entire detection systems, diodes or cameras can be traced to SI units with a typical relative uncertainty of 0.5 % to 1 % using a cryogenic electrical substitution radiometer. For reflectometry on multilayer mirrors (MLMs) PTB operates a large reflectometer accommodating samples of up to 550 mm in diameter and 50 kg in weight, allowing sample alignment in 6 degrees of freedom. The relative measurement uncertainty for the spectral reflectance is typically in the range of 0.15 % and the long-term reproducibility in the range of 0.10 %. To investigate roughness, scatterometry is employed where scattered light around the specular beam is mapped using a calibrated CCD.
引用
收藏
页数:12
相关论文
共 50 条
  • [32] Space solar telescope in soft X-ray and EUV band
    Chen Bo
    Liu Zhen
    Yang Lin
    Gao Liang
    He Fei
    Wang XiaoGuang
    Ni QiLiang
    SCIENCE IN CHINA SERIES G-PHYSICS MECHANICS & ASTRONOMY, 2009, 52 (11): : 1806 - 1809
  • [33] Temporal response of silicon EUV and soft X-ray detectors
    A. P. Artyomov
    E. H. Baksht
    V. F. Tarasenko
    A. V. Fedunin
    S. A. Chaikovsky
    P. N. Aruev
    V. V. Zabrodskii
    M. V. Petrenko
    N. A. Sobolev
    V. L. Suhanov
    Instruments and Experimental Techniques, 2015, 58 : 102 - 106
  • [34] Features of the soft X-ray background and implications for the EUV background
    Barber, CR
    Warwick, RS
    ASTROPHYSICS IN THE EXTREME ULTRAVIOLET, 1996, : 295 - 298
  • [35] Temporal response of silicon EUV and soft X-ray detectors
    Artyomov, A. P.
    Baksht, E. H.
    Tarasenko, V. F.
    Fedunin, A. V.
    Chaikovsky, S. A.
    Aruev, P. N.
    Zabrodskii, V. V.
    Petrenko, M. V.
    Sobolev, N. A.
    Suhanov, V. L.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2015, 58 (01) : 102 - 106
  • [36] Soft-x-ray harmonics in the water window
    Rundquist, A
    Chang, ZG
    Wang, HW
    Zeek, E
    Murnane, M
    Kapteyn, H
    APPLICATIONS OF HIGH-FIELD AND SHORT WAVELENGTH SOURCES, 1998, : 45 - 51
  • [37] Surface Slope Metrology on Deformable Soft X-ray Mirrors
    Yuan, Sheng
    Yashchuk, Valeriy V.
    Goldberg, Kenneth A.
    Celestre, Rich
    Church, Matthew
    McKinney, Wayne R.
    Morrison, Greg
    Warwick, Tony
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 789 - +
  • [38] Wavefront measurements in the soft X-ray range
    Le Pape, S
    Zeitoun, P
    Idir, M
    Dhez, P
    Ros, D
    Carillon, A
    Roca, JJ
    François, M
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2002, 20 (03): : 197 - 203
  • [39] Water-window flash x-ray production from linear plasma x-ray source
    Sato, E
    Sagae, M
    Toriyabe, H
    Awaji, W
    Hayasi, Y
    Takayama, K
    Ido, H
    Tamakawa, Y
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 8 - 16
  • [40] Coherent soft x-ray generation in the water window with quasi-phase matching
    Gibson, EA
    Paul, A
    Wagner, N
    Tobey, R
    Gaudiosi, D
    Backus, S
    Christov, IP
    Aquila, A
    Gullikson, EM
    Attwood, DT
    Murnane, MM
    Kapteyn, HC
    SCIENCE, 2003, 302 (5642) : 95 - 98