X-ray powder diffraction in reflection geometry on multi-beam kJ-type laser facilities

被引:7
|
作者
Denoeud, A. [1 ]
Hernandez, J-A [2 ,3 ]
Vinci, T. [2 ]
Benuzzi-Mounaix, A. [2 ]
Brygoo, S. [1 ]
Berlioux, A. [2 ]
Lefevre, F. [2 ]
Sollier, A. [1 ,4 ]
Videau, L. [1 ,4 ]
Ravasio, A. [2 ]
Guarguaglini, M. [2 ]
Duthoit, L. [1 ]
Loison, D. [5 ]
Brambrink, E. [2 ,6 ]
机构
[1] CEA, DAM, DIF, F-91297 Arpajon, France
[2] Sorbonne Univ, Inst Polytech Paris, Ecole Polytech, CEA,CNRS,LULI, F-91128 Palaiseau, France
[3] Univ Oslo, Ctr Earth Evolut & Dynam, Box 1028 Blindern, N-0315 Oslo, Norway
[4] Univ Paris Saclay, Lab Matiere Condit Extremes, CEA, F-91680 Bruyeres Le Chatel, France
[5] Univ Rennes, IPR Inst Phys Rennes UMR 6251, CNRS, F-35000 Rennes, France
[6] European XFEL, Holzkoppel 4, D-22869 Schenefeld, Germany
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2021年 / 92卷 / 01期
关键词
SHOCK COMPRESSION; TRANSITION; IRON;
D O I
10.1063/5.0020261
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An ultrafast x-ray powder diffraction setup for laser-driven dynamic compression has been developed at the LULI2000 laser facility. X-ray diffraction is performed in reflection geometry from a quasi-monochromatic laser-generated plasma x-ray source. In comparison to a transmission geometry setup, this configuration allows us to probe only a small portion of the compressed sample, as well as to shield the detectors against the x-rays generated by the laser-plasma interaction on the front side of the target. Thus, this new platform facilitates probing of spatially and temporarily uniform thermodynamic conditions and enables us to study samples of a large range of atomic numbers, thicknesses, and compression dynamics. As a proof-of-concept, we report direct structural measurements of the bcc-hcp transition both in shock and ramp-compressed polycrystalline iron with diffraction signals recorded between 2 theta similar to 30 degrees and similar to 150 degrees. In parallel, the pressure and temperature history of probed samples is measured by rear-side visible diagnostics (velocimetry and pyrometry).
引用
收藏
页数:17
相关论文
共 50 条
  • [31] A PROPOSED MULTI-BEAM X-RAY MONOCHROMATOR FOR SYNCHROTRON RADIATION - THEORETICAL CONSIDERATIONS
    LO, CM
    CHANG, SL
    JOURNAL DE PHYSIQUE, 1987, 48 (C-9): : 75 - 78
  • [32] Multi-beam X-ray Sources with Carbon Nanotube Emitter for Tomosynthesis System
    Park, Junyoung
    Jung, Jaeik
    Gupta, Amar Prasad
    Soh, Jeongtae
    Jeong, Changwon
    Ahn, Jeungsun
    Cho, Seungryong
    Yoon, Kwon-Ha
    Kim, Dongkeun
    Mativenga, Mallory
    Ryu, Jehwang
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [33] Multi-beam X-ray source breast tomosynthesis reconstruction with different algorithms
    Zhou, Weihua
    Qian, Xin
    Lu, Jianping
    Zhou, Otto
    Chen, Ying
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [34] X-ray waveguide arrays: tailored near fields by multi-beam interference
    Zhong, Q.
    Osterhoff, M.
    Wen, M. W.
    Wang, Z. S.
    Salditt, T.
    X-RAY SPECTROMETRY, 2017, 46 (02) : 107 - 115
  • [35] Determination of x-ray reflection phases using N-beam diffraction
    Chang, SL
    ACTA CRYSTALLOGRAPHICA SECTION A, 1998, 54 : 886 - 894
  • [36] Development and assessment of an x-ray tube-based multi-beam x-ray scatter projection imaging system
    Dydula, Christopher
    Johns, Paul C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (11):
  • [37] Upscaling of multi-beam x-ray ptychography for efficient x-ray microscopy with high resolution and large field of view
    Wittwer, Felix
    Lyubomirskiy, Mikhail
    Koch, Frieder
    Kahnt, Maik
    Seyrich, Martin
    Garrevoet, Jan
    David, Christian
    Schroer, Christian G.
    APPLIED PHYSICS LETTERS, 2021, 118 (17)
  • [38] Design, optimization and testing of a multi-beam micro-CT scanner based on multi-beam field emission x-ray technology
    Peng, R.
    Zhang, J.
    Calderon-Colon, X.
    Wang, S.
    Sultana, S.
    Wang, P.
    Yang, G.
    Chang, S.
    Lu, J.
    Zhou, O.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [39] The influence of reflection and transmission geometries on powder X-ray diffraction (pXRD) patterns of an API
    Barnes, C. A.
    Busby, D. J.
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2005, 57 : S82 - S82
  • [40] Femtosecond powder diffraction with a laser-driven hard X-ray source
    Zamponi, F.
    Ansari, Z.
    Woerner, M.
    Elsaesser, T.
    OPTICS EXPRESS, 2010, 18 (02): : 947 - 961