ENERGY SAVING DESIGN OF THE AIR-CONDITIONING SYSTEM IN A HOSPITAL OPERATING DEPARTMENT

被引:0
|
作者
Tang, Wenwu [1 ]
Qin, Jinzhu [1 ]
Zhang, Yizhi [1 ]
Wang, Fengfeng [1 ]
Deng, Jie [1 ]
机构
[1] Cent S Univ, Sch Energy Sci & Engn, Changsha, Hunan, Peoples R China
关键词
Operating department; Constant volume; Secondary return air; Clean air-conditioning system; Energy saving; ROOMS;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Nowadays, the hospital air conditioning expenditure depends on the costs of the operating department's air-conditioning system which provides the demanding indoor condition for operations. To reduce the operation costs, a new air-conditioning system is introduced, the comparison of energy consumption and control methods between the primary return air system (PRAS) and constant volume secondary return air system (CVSRAS) is made in this paper. In contrast with PRAS, the cost can be reduced greatly with the CVSRAS. Energy cost drops by 154.21%, 49.3%, 24.77%, and 12.15% respectively under the cleanliness class I, the class 11, the class III and the class W. In addition, the control system is not more complex than PRAS. In the CVSRAS, the temperature which needs to be dealt with by air cooler is too low. So, it is necessary to choose an appropriate air cooler in the process of design. However, in the CVSRAS, the temperature in the air duct and the fan sometimes doesn't rise to the temperature required. As a result, the air supply condition does not meet the condition required. But, concerning the temperature precision is not strictly demanded, the use of the CVSRAS in the operating department is recommended.
引用
收藏
页码:2179 / 2186
页数:8
相关论文
共 50 条
  • [41] Research on Energy-saving for Air-conditioning System based on Frequency Conversion Technology
    Zhu, Baohua
    Ning, Bo
    Du, Qiang
    [J]. ADVANCES IN MANUFACTURING TECHNOLOGY, PTS 1-4, 2012, 220-223 : 161 - 164
  • [43] The Energy Efficient Study of Air-Conditioning System Design Based on CFD
    Hu, Qinhua
    Li, Kuishan
    [J]. 2008 4TH INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS, NETWORKING AND MOBILE COMPUTING, VOLS 1-31, 2008, : 5614 - 5616
  • [44] Energy-saving study of a new air-conditioning of packing air washer
    Huang, X.
    Zhang, W. F.
    Yan, S. Q.
    Yang, Y.
    [J]. CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 600 - 603
  • [45] Energy efficient and cool storage assisted air-conditioning system for hospital building
    Maheshwari, Gopal P.
    Al-Murad, Raba'a A.
    Al-Hadban, Yehya N.
    Sebzali, Mohammed J.
    [J]. American Society of Mechanical Engineers, Advanced Energy Systems Division (Publication) AES, 2000, 40 : 481 - 487
  • [46] ENERGY AND AIR-CONDITIONING
    STEINACHER, HE
    [J]. REFRIGERATION AND AIR CONDITIONING, 1976, 79 (944): : 61 - 61
  • [47] Smart and Energy Efficient Air-Conditioning System
    Refaat, Shady S.
    Abu-Rub, Haitham
    Mohamed, Amira
    [J]. 2017 19TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'17 ECCE EUROPE), 2017,
  • [48] ENERGY-EFFICIENT AIR-CONDITIONING SYSTEM
    SUENAGA, T
    [J]. JAPAN TELECOMMUNICATIONS REVIEW, 1986, 28 (03): : 217 - 224
  • [49] Research on Subway Air-Conditioning System Design
    Chai, Zhi
    Nan, Jinrui
    Huang, Junkui
    [J]. INFORMATION TECHNOLOGY APPLICATIONS IN INDUSTRY II, PTS 1-4, 2013, 411-414 : 3039 - 3045
  • [50] Testing for Energy Recovery Ventilators and Energy Saving Analysis with Air-Conditioning Systems
    Yang, Peng
    Li, Li
    Wang, Jianqin
    Huang, Guilin
    Peng, Jingli
    [J]. 9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 438 - 445