Synchronous Link Converter Based Scheme of Harmonic Filtration for Non-Linear Load

被引:0
|
作者
Chaturvadi, Khushboo [1 ]
Goswami, Garima [2 ]
Chauhan, Deepika [3 ]
机构
[1] Jaipur Natl Univ, Jaipur, Rajasthan, India
[2] Teerthanker Mahaveer Univ, EE, Moradabad, India
[3] Poornima Coll Engn, EE, Jaipur, Rajasthan, India
关键词
Power Quality; Synchronous Link Converter; Total Harmonic Distortions; MATLAB/SIMULINK;
D O I
10.1109/smart46866.2019.9117272
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Interference due to harmonics, and generated current distortions by power electronic devices, has become a serious problem in present time. As now a days converters, which are nonlinear devices, are more and more frequently used in industrial applications, in transmission and distribution systems and in power plants. The use of non linear load by industrial or commercial purpose generates harmonic distortion, poor power factor, voltage instability, imbalance impact on the efficiency of electrical equipments in our system. The most suitable way to solve these problems is the introduction of synchronous link converter for power quality analysis for non linear loads. This paper presents the use of SLC to overcome these problems[11]. Fast Fourier transforms describe the total harmonic distortions (THD) in the line current for given non-linear system. PID controller is used here to control the action of active power filter according to required current generation, which is to be injected in distorted supply current to make it sinusoidal. The models are designed and simulated using MATLAB/SIMULINK software.
引用
下载
收藏
页码:339 / 342
页数:4
相关论文
共 50 条
  • [41] FILTRATION PROBLEM IN NON-LINEAR CONTROL-SYSTEMS
    KHOMYAKOVA, LM
    AUTOMATION AND REMOTE CONTROL, 1979, 40 (01) : 49 - 54
  • [42] Thermohydrodynamic Studies of Vertical Wells in Non-Linear Filtration
    E. R. Badertdinova
    R. M. Khairullin
    V. R. Gadil’shina
    M. Kh. Khairullin
    Lobachevskii Journal of Mathematics, 2020, 41 : 1162 - 1166
  • [43] MOTION OF SEPARATION BOUNDARY OF FLUIDS IN NON-LINEAR FILTRATION
    GOLUBEVA, OV
    PIVEN, VF
    PMM JOURNAL OF APPLIED MATHEMATICS AND MECHANICS, 1977, 41 (04): : 774 - 779
  • [44] Thermohydrodynamic Studies of Vertical Wells in Non-Linear Filtration
    Badertdinova, E. R.
    Khairullin, R. M.
    Gadil'shina, V. R.
    Khairullin, M. Kh
    LOBACHEVSKII JOURNAL OF MATHEMATICS, 2020, 41 (07) : 1162 - 1166
  • [45] Non-Linear Equations of Unsaturated Filtration in Swelling Soils
    M. G. Khramchenkov
    R. M. Usmanov
    T. R. Zakirov
    Lobachevskii Journal of Mathematics, 2021, 42 : 142 - 147
  • [46] Non-linear filtration of pulse distortions by the spallation method
    Lanne, AA
    Soloveva, EB
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 1999, 42 (7-8): : 3 - 17
  • [47] Comparison of recursive parameter estimation and non-linear filtration
    Capek, Jan
    PROCEEDINGS OF 30TH INTERNATIONAL CONFERENCE MATHEMATICAL METHODS IN ECONOMICS, PTS I AND II, 2012, : 85 - 90
  • [48] On the finite difference scheme for a non-linear evolution problem with a non-linear dynamic boundary condition
    Hlomuka, J
    INTERNATIONAL JOURNAL OF NONLINEAR SCIENCES AND NUMERICAL SIMULATION, 2006, 7 (02) : 149 - 154
  • [49] Non-Linear Load Compensation using STATCOM
    Barnawal, Prakash Ji
    Tripathi, S. M.
    2016 INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN ELECTRICAL ELECTRONICS & SUSTAINABLE ENERGY SYSTEMS (ICETEESES), 2016, : 147 - 151
  • [50] Non-linear Electrical Load Location Identification
    Pirog, Stanislav
    Shklyarskiy, Yaroslav E.
    Skamyin, Aleksandr N.
    JOURNAL OF MINING INSTITUTE, 2019, 237 : 317 - 321