Unusual Intracranial Stent Navigation through the Circle of Willis in a Patient with Recurrent Basilar Tip Aneurysm during Stent-Assisted Coiling A Case Report

被引:8
|
作者
Puri, A. S. [1 ]
Erdem, E. [1 ]
机构
[1] UAMS, Little Rock, AR 72205 USA
关键词
Enterprise stent; navigation; circle of Willis; ENDOVASCULAR TREATMENT;
D O I
10.1177/159101990901500113
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We describe a case of unusual Enterprise stent navigation through the Circle of Willis in a patient with a basilar tip aneurysm, left internal carotid artery (ICA) occlusion and previous right ICA stenting. Basilar tip aneurysms are known for their therapeutic challenges, especially when the posterior cerebral arteries (PCAs) are incorporated in the aneurysm neck. This becomes more technically demanding if the vertebral artery does not offer a route for stent navigation. We undertook stent-assisted coiling using the horizontal stenting of posterior cerebral arteries via both the posterior and anterior communicating artery navigation. This was necessary because the vertebral arteries were very tortuous, hence not suitable for stent navigation due to their small size and stenosis at their origin. Another compounding factor was the anatomy of the aneurysm neck in relation to the T-shaped origin of both P1 PCAs from the basilar artery. The right ICA was stented previously and the whole navigation was done through this stented artery as the opposite left ICA was occluded at the bifurcation. In addition, there was no visualized posterior communicating artery (PCOM) on the right side, so following navigation through the anterior communicating artery (ACOM) the le PCOM artery was catheterized to reach the PCAs. After horizontal placement of stent, coiling was performed for the residual aneurysm. The outcome of this intervention revealed successful placement of the Enterprise stent in bilateral posterior cerebral arteries covering the aneurysm. Further coiling of the basilar artery aneurysm was done with a good result. No complication was seen in the angiography suite or later in the course of action. Horizontal stent placement in wide-necked basilar aneurysms can be performed via the PCO M and ACOM arteries.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 50 条
  • [31] Stent displacement during the Y-stent assisted coil embolization of wide-neck basilar tip aneurysm
    Tan Song
    Xu Hao-wen
    Song Bo
    Avinash, Chandra
    Xu Yu-ming
    LIFE SCIENCE JOURNAL-ACTA ZHENGZHOU UNIVERSITY OVERSEAS EDITION, 2011, 8 (03): : 464 - 466
  • [32] Treatment of acute thromboembolic complication after stent-assisted coil embolization of ruptured intracranial aneurysm: a case report
    Xu, Ning
    Meng, Hao
    Liu, Tianyi
    Feng, Yingli
    Qi, Yuan
    Wang, Honglei
    NEUROPSYCHIATRIC DISEASE AND TREATMENT, 2019, 15 : 69 - 74
  • [33] Evaluation of the Accero Stent for Stent-Assisted Coiling of Unruptured Wide-Necked Intracranial Aneurysm Treatment with Short-Term Follow-Up
    Poncyljusz, Wojciech
    Kubiak, Kinga
    Sagan, Leszek
    Limanowka, Bartosz
    Kolaczyk, Katarzyna
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (09) : 1 - 8
  • [34] Hyperacute in-Stent Thrombosis Causing Large Vessel Occlusion after Stent-Assisted Aneurysm Coiling Secondary to Complete Clopidogrel and Prasugrel Resistance: a Case Report
    Xian, Elissa
    Morrison, Thomas
    Wong, Johnny
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2024, 85 (05) : 531 - 533
  • [35] Stretched and fractured Neuroform Atlas® stent during a stent-assisted coil embolization: A case report
    Ko, Hak Cheol
    Shin, Hee Sup
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2023, 25 (05)
  • [36] Double porous media modeling in computational fluid dynamics for hemodynamics of stent-assisted coiling of intracranial aneurysms: A technical case report
    Tsuji, Masanori
    Ishida, Fujimaro
    Kishimoto, Tomoyuki
    Furukawa, Kazuhiro
    Miura, Yoichi
    Shiba, Masato
    Sano, Takanori
    Fukazawa, Keiji
    Tanaka, Katsuhiro
    Tanemura, Hiroshi
    Umeda, Yasuyuki
    Yasuda, Ryuta
    Shimosaka, Shinichi
    Suzuki, Hidenori
    BRAIN HEMORRHAGES, 2020, 1 (01): : 85 - 88
  • [37] Use of the pipeline embolization device for the treatment of recurrent intracranial aneurysm after previous stent-assisted embolization
    Wong, George K. C.
    Tan, Hai-Bin
    Yu, Simon C. H.
    Poon, Wai-Sang
    SURGICAL PRACTICE, 2011, 15 (01) : 29 - 30
  • [38] Stent-assisted percutaneous transluminal angioplasty for intracranial vertebral and basilar artery stenosis: Two case reports
    Yoshizumi, H
    Inoya, H
    Masuzawa, H
    Sato, K
    Nakamura, S
    NEUROLOGICAL SURGERY, 2004, 32 (06): : 627 - 634
  • [39] Pipeline Embolization Device Versus Stent-Assisted Coiling for Intracranial Aneurysm Treatment: A Retrospective Propensity Score-Matched Study
    Salem, Mohamed M.
    Ravindran, Krishnan
    Enriquez-Marulanda, Alejandro
    Ascanio, Luis C.
    Jordan, Noah
    Gomez-Paz, Santiago
    Foreman, Paul M.
    Ogilvy, Christopher S.
    Thomas, Ajith J.
    Moore, Justin M.
    NEUROSURGERY, 2020, 87 (03) : 516 - 522
  • [40] Pipeline Embolization Device Versus Stent-Assisted Coiling for Intracranial Aneurysm Treatment: A Retrospective Propensity Score-Matched Study
    Salem, Mohamed M.
    Ravindran, Krishnan
    Enriquez-Marulanda, Alejandro
    Ascanio, Luis C.
    Jordan, Noah
    Gomez-Paz, Santiago
    Foreman, Paul M.
    Ogilvy, Christopher S.
    Thomas, Ajith J.
    Moore, Justin M.
    NEUROSURGERY, 2021, 89 : S17 - S17