Measurement of the thermal conductivity of argon and methane:: a test of a transient hot-wire apparatus

被引:18
|
作者
Pátek, J [1 ]
Klomfar, J [1 ]
机构
[1] Acad Sci Czech Republ, Inst Thermomech, CZ-18200 Prague 8, Czech Republic
关键词
thermal conductivity; pure; transient hot-wire apparatus; argon; methane;
D O I
10.1016/S0378-3812(01)00763-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
A transient hot-wire apparatus for absolute measurements of the thermal conductivity of gases has been constructed and tested with argon and methane. The apparatus operates at temperatures from about 300 to 473 K and pressures up to 60MPa. To evaluate the capability of the apparatus. measurements were per-formed (i) with argon along five isotherms at temperatures between 300 and 425 K with pressures up to 15 MPa. and (ii) with methane along seven isotherms at temperatures between 290 and 360 K with pressures up to 15 MPa. The experimental thermal conductivity data and the results of their low-density analysis are compared with results of other investigators. The total experimental uncertainty of the measurements is estimated to be +/- 0.00 1 x p in pressure and +/- 0.005 K in temperature, The relative uncertainty of the measurements at 95% level is estimated to be 1.2% for argon and 0.7% for methane. The reproducibility of the results measured by the standard deviation from the polynomial lambda(rho) relation along isotherms is 0.3% for argon and 0.2% for methane. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:147 / 163
页数:17
相关论文
共 50 条
  • [21] FULLY AUTOMATED APPARATUS TO MEASURE THE THERMAL-CONDUCTIVITY OF LIQUIDS BY THE TRANSIENT HOT-WIRE METHOD
    KAWAGUCHI, N
    NAGASAKA, Y
    NAGASHIMA, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (09): : 1788 - 1794
  • [22] MEASUREMENT OF THERMAL-CONDUCTIVITY BY HOT-WIRE METHOD
    VILCU, R
    CIOCHINA, A
    REVUE ROUMAINE DE CHIMIE, 1972, 17 (10) : 1679 - &
  • [23] Further examination of the transient hot-wire method for the simultaneous measurement of thermal conductivity and thermal diffusivity
    Watanabe, H
    METROLOGIA, 2002, 39 (01) : 65 - 81
  • [24] A Novel Portable Absolute Transient Hot-Wire Instrument for the Measurement of the Thermal Conductivity of Solids
    Assael, Marc J.
    Antoniadis, Konstantinos D.
    Metaxa, Ifigeneia N.
    Mylona, Sofia K.
    Assael, John-Alexander M.
    Wu, Jiangtao
    Hu, Miaomiao
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2015, 36 (10-11) : 3083 - 3105
  • [25] A Transient Hot-Wire Instrument for the Measurement of the Thermal Conductivity of Solids up to 590 K
    M. J. Assael
    K. Gialou
    International Journal of Thermophysics, 2003, 24 : 667 - 674
  • [26] A Novel Portable Absolute Transient Hot-Wire Instrument for the Measurement of the Thermal Conductivity of Solids
    Marc J. Assael
    Konstantinos D. Antoniadis
    Ifigeneia N. Metaxa
    Sofia K. Mylona
    John-Alexander M. Assael
    Jiangtao Wu
    Miaomiao Hu
    International Journal of Thermophysics, 2015, 36 : 3083 - 3105
  • [27] THE BOUNDARY INDUCED ERROR ON THE MEASUREMENT OF THERMAL-CONDUCTIVITY BY TRANSIENT HOT-WIRE METHOD
    LIANG, XG
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (05) : 467 - 471
  • [28] A transient hot-wire instrument for the measurement of the thermal conductivity of solids up to 590 K
    Assael, MJ
    Gialou, K
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2003, 24 (03) : 667 - 674
  • [29] Thermal conductivity measurement of fluoride molten salt FLiNaK by transient hot-wire method
    Ueki, Yoshitaka (ueki@mech.eng.osaka-u.ac.jp), 1600, Old City Publishing (46):
  • [30] Thermal conductivity measurement of fluoride molten salt FLiNaK by transient hot-wire method
    Ueki, Yoshitaka
    Fujita, Naoyuki
    Yagi, Juro
    Shibaraha, Masahiko
    Sagara, Akio
    HIGH TEMPERATURES-HIGH PRESSURES, 2017, 46 (03) : 247 - 254