Ozonation for source treatment of pharmaceuticals in hospital wastewater - Ozone lifetime and required ozone dose

被引:117
|
作者
Hansen, Kamilla M. S. [1 ]
Spiliotopoulou, Aikaterini [2 ]
Chhetri, Ravi Kumar [1 ]
Casas, Monica Escola [3 ]
Bester, Kai [3 ]
Andersen, Henrik R. [1 ]
机构
[1] Tech Univ Denmark, Dept Environm Engn, Miljovej 113, DK-2800 Lyngby, Denmark
[2] Water ApS, Farum Gydevej 64, DK-3520 Farum, Denmark
[3] Aarhus Univ, Dept Environm Sci, Frederiksborgvej 399, DK-4000 Roskilde, Denmark
关键词
Ozone; Pharmaceuticals; Hospital wastewater; DOC; pH; Lifetime; MICROPOLLUTANT ELIMINATION; ESTROGENIC CHEMICALS; ADVANCED OXIDATION; EFFLUENTS; REMOVAL; BIODEGRADATION; DECOMPOSITION; PREDICTION; EFFICIENCY; BIOFILM;
D O I
10.1016/j.cej.2016.01.027
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ozonation aimed at removing pharmaceuticals was studied in an effluent from an experimental pilot system using staged moving bed biofilm reactor (MBBR) tanks for the optimal biological treatment of wastewater from a medical care unit of Aarhus University Hospital. Dissolved organic carbon (DOC) and pH in samples varied considerably, and the effect of these two parameters on ozone lifetime and the efficiency of ozone in removing pharmaceuticals were determined. The pH in the effluent varied from 5.0 to 9.0 resulting in approximately a doubling of the required ozone dose at the highest pH for each pharmaceutical. DOC varied from 6 to 20 mg-DOC/L. The ozone required for removing each pharmaceutical, varied linearly with DOC and thus, ozone doses normalized to DOC (specific ozone dose) agreed between water samples (typically within 15%). At neutral pH the specific ozone dose required to remove the easiest degradable pharmaceutical, sulfadiazine, was 0.50 +/- 0.04 mg-O-3/mg-DOC and the most recalcitrant, diatrizoic acid, required 4.7 +/- 0.6 mg-O-3/mg-DOC. The lifetime of ozone increased drastically in the higher end of the indicated dosage. At the lowest observed pH of 5.0, its lifetime was quadrupled to 20 min which influences the design of the reaction tank. The addition of 0.1 mg-H2O2 per 1 mg-O-3 mitigated the prolonged lifetime without a corresponding influence in the pharmaceutical removal efficiency of ozone. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:507 / 514
页数:8
相关论文
共 50 条
  • [31] Applications of ozone for industrial wastewater treatment - A review
    Rice, RG
    OZONE-SCIENCE & ENGINEERING, 1997, 18 (06) : 477 - 515
  • [32] Optimisation of ozone production for water and wastewater treatment
    Alsheyab, Mohammad A. T.
    Munoz, Aurelio H.
    DESALINATION, 2007, 217 (1-3) : 1 - 7
  • [33] RECYCLING DYE WASTEWATER THROUGH OZONE TREATMENT
    COX, AG
    TEXTILE INDUSTRIES, 1983, 147 (07): : 26 - &
  • [34] Treatment of dairy wastewater by ozone and biological process
    Krzeminska, D.
    Neczaj, E.
    ENVIRONMENTAL ENGINEERING IV, 2013, : 103 - 110
  • [35] Applications of ozone in Japan for water and wastewater treatment
    Yasutake, S.
    Kato, M.
    Kono, S.
    Ozone: Science and Engineering, 1988, 10 (03): : 309 - 320
  • [36] Ozone treatment of wastewater sludge for reduction and stabilization
    Park, K.Y.
    Maeng, S.K.
    Song, K.G.
    Ahn, K.H.
    Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering, 2008, 43 (13 SPEC. ISS.): : 1546 - 1550
  • [37] Methodology of ozone introduction into water and wastewater treatment
    Munter, R.
    Preis, S.
    Kamenev, S.
    Siirde, E.
    Ozone: Science and Engineering, 1993, 15 (02): : 149 - 165
  • [38] Ozone treatment of olive mill wastewater.
    Alonso, JBD
    Antón, JT
    Rodríguez, JG
    Vargas, JRD
    GRASAS Y ACEITES, 2000, 51 (05) : 301 - 306
  • [39] USE OF OZONE AND OXYGEN IN ADVANCED WASTEWATER TREATMENT
    ROSEN, HM
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1973, 45 (12): : 2521 - 2536
  • [40] USE OF OZONE AND OXYGEN IN ADVANCED WASTEWATER TREATMENT
    CHRISTENSEN, GL
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1974, 46 (08): : 2054 - 2055