Ozonation for source treatment of pharmaceuticals in hospital wastewater - Ozone lifetime and required ozone dose

被引:117
|
作者
Hansen, Kamilla M. S. [1 ]
Spiliotopoulou, Aikaterini [2 ]
Chhetri, Ravi Kumar [1 ]
Casas, Monica Escola [3 ]
Bester, Kai [3 ]
Andersen, Henrik R. [1 ]
机构
[1] Tech Univ Denmark, Dept Environm Engn, Miljovej 113, DK-2800 Lyngby, Denmark
[2] Water ApS, Farum Gydevej 64, DK-3520 Farum, Denmark
[3] Aarhus Univ, Dept Environm Sci, Frederiksborgvej 399, DK-4000 Roskilde, Denmark
关键词
Ozone; Pharmaceuticals; Hospital wastewater; DOC; pH; Lifetime; MICROPOLLUTANT ELIMINATION; ESTROGENIC CHEMICALS; ADVANCED OXIDATION; EFFLUENTS; REMOVAL; BIODEGRADATION; DECOMPOSITION; PREDICTION; EFFICIENCY; BIOFILM;
D O I
10.1016/j.cej.2016.01.027
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ozonation aimed at removing pharmaceuticals was studied in an effluent from an experimental pilot system using staged moving bed biofilm reactor (MBBR) tanks for the optimal biological treatment of wastewater from a medical care unit of Aarhus University Hospital. Dissolved organic carbon (DOC) and pH in samples varied considerably, and the effect of these two parameters on ozone lifetime and the efficiency of ozone in removing pharmaceuticals were determined. The pH in the effluent varied from 5.0 to 9.0 resulting in approximately a doubling of the required ozone dose at the highest pH for each pharmaceutical. DOC varied from 6 to 20 mg-DOC/L. The ozone required for removing each pharmaceutical, varied linearly with DOC and thus, ozone doses normalized to DOC (specific ozone dose) agreed between water samples (typically within 15%). At neutral pH the specific ozone dose required to remove the easiest degradable pharmaceutical, sulfadiazine, was 0.50 +/- 0.04 mg-O-3/mg-DOC and the most recalcitrant, diatrizoic acid, required 4.7 +/- 0.6 mg-O-3/mg-DOC. The lifetime of ozone increased drastically in the higher end of the indicated dosage. At the lowest observed pH of 5.0, its lifetime was quadrupled to 20 min which influences the design of the reaction tank. The addition of 0.1 mg-H2O2 per 1 mg-O-3 mitigated the prolonged lifetime without a corresponding influence in the pharmaceutical removal efficiency of ozone. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:507 / 514
页数:8
相关论文
共 50 条
  • [1] Required ozone doses for removing pharmaceuticals from wastewater effluents
    Antoniou, Maria G.
    Hey, Gerly
    Rodriguez Vega, Sergio
    Spiliotopoulou, Aikaterini
    Fick, Jerker
    Tysklind, Mats
    Jansen, Jes la Cour
    Andersen, Henrik Rasmus
    SCIENCE OF THE TOTAL ENVIRONMENT, 2013, 456 : 42 - 49
  • [2] Ozone dose dependent formation and removal of ozonation products of pharmaceuticals in pilot and full-scale municipal wastewater treatment plants
    Kharel, Suman
    Stapf, Michael
    Miehe, Ulf
    Ekblad, Maja
    Cimbritz, Michael
    Falas, Per
    Nilsson, Josefine
    Sehlen, Robert
    Bester, Kai
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 731
  • [3] VARIABILITY IN REQUIRED OZONE DOSES FOR REMOVING PHARMACEUTICALS FROM WASTEWATER EFFLUENTS
    Antoniou, Maria G.
    Hey, Gerly
    Rodriguez Vega, Sergio
    Spiliotopoulou, Aikaterini
    Fick, Jerker
    Tysklind, Mats
    Jansen, Jes La Cour
    Andersen, Henrik Rasmus
    PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2013,
  • [4] Removal of pharmaceuticals with ozone at 10 Swedish wastewater treatment plants
    Nilsson F.
    Ekblad M.
    la Cour Jansen J.
    Jönsson K.
    Water Practice and Technology, 2017, 12 (04): : 871 - 881
  • [5] Ozone treatment process for the removal of pharmaceuticals and personal care products in wastewater
    Paucar, N. Evelin
    Kim, Ilho
    Tanaka, Hiroaki
    Sato, Chikashi
    OZONE-SCIENCE & ENGINEERING, 2019, 41 (01) : 3 - 16
  • [6] Influence of pH and ozone dose on sulfaquinoxaline ozonation
    Urbano, Vanessa Ribeiro
    Maniero, Milena Guedes
    Perez-Moya, Montserrat
    Guimaraes, Jose Roberto
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2017, 195 : 224 - 231
  • [7] Inactivation of Bacteria and Residual Antimicrobials in Hospital Wastewater by Ozone Treatment
    Azuma, Takashi
    Katagiri, Miwa
    Sekizuka, Tsuyoshi
    Kuroda, Makoto
    Watanabe, Manabu
    ANTIBIOTICS-BASEL, 2022, 11 (07):
  • [8] Giving wastewater the ozone treatment
    不详
    MER-MARINE ENGINEERS REVIEW, 2001, : 56 - 56
  • [9] Ozonation of Wastewater: Rate of Ozone Consumption and Hydroxyl Radical Yield
    Noethe, Tobias
    Fahlenkamp, Hans
    von Sonntag, Clemens
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (15) : 5990 - 5995
  • [10] Use of Ozone-Based Processes for the Removal of Pharmaceuticals Detected in a Wastewater Treatment Plant
    Kim, Ilho
    Tanaka, Hiroaki
    WATER ENVIRONMENT RESEARCH, 2010, 82 (04) : 294 - 301