Performance of a biofilter for the removal of high concentrations of styrene under steady and non-steady state conditions

被引:49
|
作者
Rene, Eldon R. [1 ]
Veiga, Maria C. [1 ]
Kennes, Christian [1 ]
机构
[1] Univ A Coruna, Fac Sci, Chem Engn Lab, E-15008 La Coruna, Spain
关键词
Volatile organic compounds; Biofiltration; Styrene; Perlite; Elimination capacity; Removal efficiency; Relative humidity; Transient operations; PSEUDOMONAS SP SR-5; POLLUTED AIR; HYDROGEN-SULFIDE; ALPHA-PINENE; PILOT-SCALE; DEGRADATION; BIOFILTRATION; BIOTREATMENT; TOLUENE; VAPORS;
D O I
10.1016/j.jhazmat.2009.02.032
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance of a laboratory scale perlite biofilter inoculated with a mixed culture was evaluated for gas phase styrene removal under various operating conditions. Experiments were carried out by subjecting the biofilter to different flow rates (0.15-0.9 m(3) h(-1)) and concentrations (0.03-17.3 g m(-3)), corresponding to inlet loading rates varying from as low as 3 g m(-3) h(-1) to as high as 1390 g m(-3) h(-1). A maximum elimination capacity (EC) of 382 g m(-3) h(-1) was achieved at an inlet loading rate of 464 g m(-3) h(-1) with a removal efficiency of 82% The high elimination capacity reached with this system could have been due to the dominant presence of filamentous fungi among others. The impact of relative humidity (RH) (30%, 60% and >92%) on the biofilter performance was evaluated at two constant loading rates, viz., 80 and 260 g m(-3) h(-1), showing that inhibitory effects were only significant when combining the highest loads with the lowest relative humidities. Biomass distribution, moisture content and concentration profiles along the bed height were significantly dependent on the relative humidity of the inlet air and on the loading rate. The dynamic behaviour of the biofilter through vigorous short and long-term shock loads was tested at different process conditions. The biofilter was found to respond apace to rapid changes in loading conditions. The stability of the biomass within the reactor was apparent from the fast response of the biofilter to recuperate and handle intermittent shutdown and restart operations, either with or without nutrient addition. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:282 / 290
页数:9
相关论文
共 50 条
  • [22] Analysis of steady state and non-steady state corneal permeation of diclofenac
    Mohapatra, Rajaram
    Mallick, Subrata
    Nanda, Ashirbad
    Sahoo, Rudra N.
    Pramanik, Arunima
    Bose, Anindya
    Das, Debajyoti
    Pattnaik, Lolly
    RSC ADVANCES, 2016, 6 (38) : 31976 - 31987
  • [23] COULOMETRIC MEASUREMENT OF CURRENT OUTPUT IN METALS DEPOSITION UNDER NON-STEADY STATE CONDITIONS
    TAUBE, K
    LORENZ, WJ
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1970, 25 (01): : 95 - &
  • [24] Refrigerant mass inside an evaporator in a steady or non-steady state
    Machado, L
    Haberschill, P
    Lallemand, M
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1998, 21 (06): : 430 - 439
  • [25] NON-STEADY STATE OF A HERZENBERG DYNAMO
    RIKITAKE, T
    HAGIWARA, Y
    JOURNAL OF GEOMAGNETISM AND GEOELECTRICITY, 1966, 18 (03): : 393 - &
  • [26] NON-STEADY STATE MECHANISM OF YIELD
    FAUCHER, B
    KRAUSZ, AS
    SCRIPTA METALLURGICA, 1978, 12 (02): : 175 - 179
  • [27] MATHEMATICS OF NON-STEADY STATE DIAGENESIS
    LASAGA, AC
    HOLLAND, HD
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1974, 55 (07): : 696 - 696
  • [28] The non-steady state of pregnancy - Reply
    Stulc, J
    Stulcova, B
    AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 1997, 272 (01) : R439 - R440
  • [29] Resource competition of Cyanobacteria, Chlorococcalesa and diatoms for ammonium ions under steady and non-steady state
    Yang, Su Wen
    Jin, Xiang Can
    INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 2010, 43 (04) : 364 - 376