Flow pattern in reverse-flow centrifugal separators

被引:111
|
作者
Peng, W
Hoffmann, AC
Boot, PJAJ
Udding, A
Dries, HWA
Ekker, A
Kater, J
机构
[1] Univ Bergen, Dept Phys, N-5007 Bergen, Norway
[2] Tsing Hua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[3] Univ Groningen, Dept Chem Engn, NL-9747 AG Groningen, Netherlands
[4] Amsterdam Shell Res BV, Shell Global Solut, NL-1030 BN Amsterdam, Netherlands
关键词
flow pattern; reverse flow; centrifugal separators;
D O I
10.1016/S0032-5910(02)00148-1
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Experimental flow patterns, determined by Laser Doppler Anemometry (LDA) for two types of reverse-flow centrifugal separators, are presented. The flow patterns in (a) a conventional cylinder-on-cone cyclone with tangential inlet and (b) a swirl tube with vane-generated swirl and a cylindrical body are compared. The experimental data are also used to test the validity of the flow assumptions of some widely used cyclone separation models for each of the two devices. The measured flow patterns are also compared with the results of computational fluid dynamics (CFD) simulations wherever this was helpful for the interpretation. Although the data globally support the standard flow assumptions, some features were quite surprising; for instance, it appears that the surface delimiting the central region of upward flow is largely determined by the diameter of the body and not that of the vortex finder. The similarities and differences between the flow patterns in cyclones and swirl tubes are discussed, as is the suitability of using cyclone separation models for the prediction of swirl tube performance. (C) 2002 Elsevier Science B.V All rights reserved.
引用
收藏
页码:212 / 222
页数:11
相关论文
共 50 条
  • [21] Robust control of a reverse-flow reactor
    Fissore, Davide
    Barresi, Antonello A.
    CHEMICAL ENGINEERING SCIENCE, 2008, 63 (07) : 1901 - 1913
  • [22] The influence of anaesthetics on the reverse-flow fasciocutaneous flaps
    Wang, Xin
    Chang, Shi-min
    Yu, Guang-rong
    BURNS, 2011, 37 (01) : 174 - 175
  • [23] Forced temperature oscillations in reverse-flow reactors
    Thullie, Jan
    Kocur, Alicja
    Inzynieria Chemiczna i Procesowa, 2002, 22 (04): : 717 - 730
  • [24] New posibilities in design of reverse-flow reactors
    Thullie, J
    Bodzek, M
    Kurpas, M
    INZYNIERIA CHEMICZNA I PROCESOWA, 2001, 22 (3E): : 1393 - 1398
  • [25] STUDIES OF FLOW IN DISK DRUMS OF CENTRIFUGAL SEPARATORS
    BALLA, A
    SCHMIDT, HH
    FRITSCHE, E
    CHEMISCHE TECHNIK, 1972, 24 (10): : 621 - &
  • [26] Reverse-flow reactor for a selective oxidation process
    Ferreira, RQ
    Costa, CA
    Masetti, S
    CHEMICAL ENGINEERING SCIENCE, 1999, 54 (20) : 4615 - 4627
  • [27] Forced temperature oscillations in reverse-flow reactors
    Thullie, J
    Kocur, A
    INZYNIERIA CHEMICZNA I PROCESOWA, 2001, 22 (04): : 717 - 730
  • [28] Oblique radial forearm reverse-flow flap
    Akyürek, M
    Safak, T
    Keçik, A
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2003, 19 (01) : 3 - 6
  • [29] Application of temperature oscillations in reverse-flow reactors
    Thullie, J
    Kocur, A
    INZYNIERIA CHEMICZNA I PROCESOWA, 2001, 22 (3E): : 1399 - 1404
  • [30] Autothermal Reforming of Methane in a Reverse-Flow Reactor
    Liu, Tengfei
    Temur, Hakan
    Veser, Goetz
    CHEMICAL ENGINEERING & TECHNOLOGY, 2009, 32 (09) : 1358 - 1366