Associations Between the Time in Hypoglycemia and Hypoglycemia Awareness Status in Type 1 Diabetes Patients Using Continuous Glucose Monitoring Systems

被引:14
|
作者
Lin, Yu Kuei [1 ]
Groat, Danielle [2 ]
Chan, Owen [1 ]
Hung, Man [3 ]
Sharma, Anu [1 ]
Varner, Michael W. [4 ]
Gouripeddi, Ramkiran [2 ]
Facelli, Julio C. [2 ]
Fisher, Simon J. [1 ]
机构
[1] Univ Utah, Sch Med, Dept Internal Med, Div Endocrinol Metab & Diabet, Salt Lake City, UT USA
[2] Univ Utah, Dept Biomed Informat, Salt Lake City, UT USA
[3] Univ Utah, Sch Med, Study Design & Biostat Ctr, Ctr Clin & Translat Sci, Salt Lake City, UT USA
[4] Univ Utah, Sch Med, Dept Obstet & Gynecol, Salt Lake City, UT 84132 USA
关键词
Hypoglycemia; Impaired awareness of hypoglycemia; Continuous glucose monitoring; Type; 1; diabetes; IMPAIRED AWARENESS; GLYCEMIC THRESHOLDS; INSULIN INJECTIONS; AUTONOMIC FAILURE; ADULTS; COUNTERREGULATION; MULTICENTER; CONSENSUS; SYMPTOMS;
D O I
10.1089/dia.2020.0016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:Continuous glucose monitoring (CGM) systems help reduce hypoglycemia in patients with type 1 diabetes (T1D). It remains unclear whether T1D patients with impaired awareness of hypoglycemia (IAH) continue to develop more hypoglycemia than those with normal hypoglycemia awareness (NA) despite CGM use. Materials and Methods:For this cross-sectional observational study, 99 T1D patients using real-time CGMs for >= 86% of time were recruited. Fifty and 49 patients were found to have NA and IAH (based on the Clarke questionnaire), respectively. Two-week CGM hypoglycemia data were collected. Results:IAH was associated with greater percentages of CGM values <70 and <54 mg/dL (P = 0.012,P = 0.004) compared to NA. Clarke scores correlated positively with the percentage of CGM values <70 and <54 mg/dL (P = 0.013,P = 0.004). IAH was also related to more events with glucose <70 and <54 mg/dL determined either with at >= 1 time point (P = 0.048,P = 0.003) or lasting >= 20 min (P = 0.016,P = 0.004). IAH patients presented with more day-time events with glucose <54 mg/dL (P = 0.015), nocturnal events with glucose levels <70 and <54 mg/dL (P = 0.009,P = 0.007) and longer day-time event duration with glucose levels <70 and <54 mg/dL (P < 0.001,P = 0.006), respectively. Conclusions:T1D patients with IAH continue to experience more hypoglycemia despite dedicated CGM use.
引用
收藏
页码:787 / 793
页数:7
相关论文
共 50 条
  • [1] Relationships of hypoglycemia awareness, hypoglycemia beliefs, and continuous glucose monitoring glycemic profiles with anxiety and depression symptoms in adults with type 1 diabetes using continuous glucose monitoring systems
    Lin, Yu Kuei
    Hepworth, Emily
    de Zoysa, Nicole
    Mccurley, Jessica
    Vajravelu, Mary Ellen
    Ye, Wen
    Piatt, Gretchen A.
    Amiel, Stephanie A.
    Fisher, Simon J.
    Pop-Busui, Rodica
    Aikens, James E.
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2024, 209
  • [2] CONTINUOUS GLUCOSE MONITORING IS MORE EFFECTIVE THAN FLASH GLUCOSE MONITORING IN PREVENTING HYPOGLYCEMIA IN PATIENTS WITH TYPE 1 DIABETES AND NORMAL AWARENESS OF HYPOGLYCEMIA
    Haskova, A.
    Radovnicka, L.
    Parkin, C.
    Grunberger, G.
    Horova, E.
    Kade, O.
    Matoulek, M.
    Prazny, M.
    Oupal, J. S.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A129 - A129
  • [3] Higher Glucose Thresholds for Hypoglycemia Alarms on Continuous Glucose Monitoring Systems (CGMs) Are Associated with Less Time in Hypoglycemia in Patients with Impaired Awareness of Hypoglycemia
    Lin, Yu Kuei
    Groat, Danielle
    Chan, Owen
    Pop-Busui, Rodica
    Varner, Michael
    Fisher, Simon
    [J]. DIABETES, 2020, 69
  • [4] Real-time continuous glucose monitoring decreases the risk of severe hypoglycemia in people with type 1 diabetes and impaired awareness of hypoglycemia
    Lucidi, Paola
    Porcellati, Francesca
    Bolli, Geremia B.
    Fanelli, Carmine G.
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2018, 6
  • [5] Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes
    Battelino, Tadej
    Phillip, Moshe
    Bratina, Natasa
    Nimri, Revital
    Oskarsson, Per
    Bolinder, Jan
    [J]. DIABETES CARE, 2011, 34 (04) : 795 - 800
  • [6] Continuous Glucose Monitoring in Patients with Type 1 Diabetes and Impaired Awareness of Hypoglycemia: Also Effective in Patients with Psychological Distress?
    van Beers, Cornelis A. J.
    de Wit, Maartje
    Kleijer, Susanne J.
    Geelhoed-Duijvestijn, Petronella H.
    DeVries, J. Hans
    Kramer, Mark H. H.
    Diamant, Michaela
    Serne, Erik H.
    Snoek, Frank J.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 (10) : 595 - 599
  • [7] Effect of real-time continuous glucose monitoring on hypoglycemia in adult type 1 diabetes patients
    Jia, Weiping
    [J]. JOURNAL OF DIABETES INVESTIGATION, 2018, 9 (03): : 478 - 480
  • [8] Real-Time Continuous Glucose Monitoring Significantly Reduces Severe Hypoglycemia in Hypoglycemia-Unaware Patients With Type 1 Diabetes
    Choudhary, Pratik
    Ramasamy, Sharmin
    Green, Louisa
    Gallen, Geraldine
    Pender, Siobhan
    Brackenridge, Anna
    Amiel, Stephanie A.
    Pickup, John C.
    [J]. DIABETES CARE, 2013, 36 (12) : 4160 - 4162
  • [9] IMPAIRED AWARENESS OF HYPOGLYCEMIA CONTINUES TO BE A RISK FACTOR FOR SEVERE HYPOGLYCEMIA DESPITE THE USE OF CONTINUOUS GLUCOSE MONITORING SYSTEM IN TYPE 1 DIABETES
    Lin, Yu Kuei
    Hung, Man
    Sharma, Anu
    Chan, Owen
    Varner, Michael W.
    Staskus, Gitana
    Fisher, Simon J.
    [J]. ENDOCRINE PRACTICE, 2019, 25 (06) : 517 - 525
  • [10] Risk factors of severe hypoglycemia and occurrence of silent hypoglycemia in patients with type 1 diabetes assessed by continuous glucose monitoring
    Hoi-Hansen, T
    Pedersen-Bjergaard, U
    Pramming, S
    Thorsteinsson, B
    [J]. DIABETES, 2005, 54 : A153 - A154