Effect of cross-flow on the performance of air-cooled heat exchanger fans

被引:35
|
作者
Stinnes, WH [1 ]
von Backström, TW [1 ]
机构
[1] Univ Stellenbosch, Dept Mech Engn, ZA-7602 Matieland, South Africa
关键词
air-cooled; heat exchangers; cooling plant performance; axial fans; distorted flow; cross-flow; off-axis inflow; fan performance; system effect;
D O I
10.1016/S1359-4311(02)00060-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
In large-scale applications such as arrays of axial fans in air-cooled heat exchanger systems, edge-proximity and wind-induced cross-flow may decrease the flow through some fans by causing the flow to enter them at off-axis angles. In this study, such off-axis inflows were introduced by inserting inlet pipe sections between the plenum chamber of a standard test facility and one of three different scale model test fans of 1542 mm diameter. Fan power consumption turned out to be completely independent of off-axis inflow angle up to 45degrees. Fan total-to-total pressure rise was found to be independent of off-axis inflow angle, and the decrement in fan pressure rise was equal to the dynamic pressure based on the cross-flow velocity component at the fan inlet. Analysis showed that for model fans to represent the cross-flow behaviour of their prototypes, they should have the same ratio of dynamic pressure to pressure rise, and the same dimensionless characteristic slope at their operating points. The performance of a row of fans operating at off-axis inflow conditions representing a cooling system was well predicted by a simple model assuming that the fans farther from the edges induce cross-flows over the fans closer to the edges. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1403 / 1415
页数:13
相关论文
共 50 条
  • [41] Erosion in the tube entrance region of an air-cooled heat exchanger
    Badr, HM
    Habib, MA
    Ben-Mansour, R
    Said, SAM
    Al-Anizi, SS
    INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2006, 32 (09) : 1440 - 1463
  • [42] Optimizing air-cooled heat exchanger tube bundle parameters
    Evenko, VI
    CHEMICAL AND PETROLEUM ENGINEERING, 2002, 38 (1-2) : 41 - 47
  • [43] Flow maldistribution and thermal performance deterioration in a cross-flow air to air heat exchanger with plate-fin cores
    Zhang, Li-Zhi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (19-20) : 4500 - 4509
  • [44] An invariant control system of an air-cooled heat exchanger of gas
    Mochalin D.S.
    Titov V.G.
    Russ Electr Eng, 8 (459-463): : 459 - 463
  • [45] Cooling performance evaluation for double-layer configuration of air-cooled heat exchanger
    Wang, Weijia
    Chen, Lei
    Kong, Yanqiang
    Yang, Lijun
    Niu, Yuguang
    Du, Xiaoze
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 151
  • [46] Enhance air-cooled heat exchanger performance (vol 80, pg 49, 2001)
    Shastri, SS
    Karimi, IA
    Rangaiah, GP
    Yap, C
    HYDROCARBON PROCESSING, 2002, 81 (05): : 43 - 43
  • [47] Anti-freezing of air-cooled heat exchanger by air flow control of louvers in power plants
    Chen, Lei
    Yang, Lijun
    Du, Xiaoze
    Yang, Yongping
    APPLIED THERMAL ENGINEERING, 2016, 106 : 537 - 550
  • [48] EFFECT OF THE LONGITUDINAL HEAT-CONDUCTION AND THE FLOW NONUNIFORMITY ON THE THERMAL PERFORMANCE OF CROSS-FLOW HEAT-EXCHANGER
    CHIOU, JP
    MECHANICAL ENGINEERING, 1979, 101 (03) : 96 - 96
  • [49] Numerical study on thermal performance of an air-cooled heat exchanger: Effects of hybrid nanofluid, pipe arrangement and cross section
    Karimi, Ali
    Afrand, Masoud
    ENERGY CONVERSION AND MANAGEMENT, 2018, 164 : 615 - 628
  • [50] Axial Flow Fan Performance in a Forced Draught Air-Cooled Heat Exchanger for a Supercritical Carbon Dioxide Brayton Cycle
    Boshof, Francois D.
    van der Spuy, Sybrand J.
    Pretorius, Johannes P.
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2025, 147 (01):