Reduction of Beam Current Noise in the FNAL Magnetron Ion Source

被引:3
|
作者
Bollinger, D. S. [1 ]
Karns, P. R. [1 ]
Tan, C. Y. [1 ]
机构
[1] Fermilab Natl Accelerator Lab, Proton Source Dept, Batavia, IL 60510 USA
关键词
D O I
10.1063/1.4916482
中图分类号
O59 [应用物理学];
学科分类号
摘要
The new FNAL Injector Line with a circular dimple magnetron ion source has been operational since December of 2012. Since the new injector came on line there have been variations in the H-beam current flattop observed near the downstream end of the Linac. Several different cathode geometries including a hollow cathode suggested by Dudnikov [1] were tried. Previous studies also showed that different mixtures of hydrogen and nitrogen had an effect on beam current noise [2]. We expanded on those studies by trying mixtures ranging from (0.25% nitrogen, 99.75% hydrogen) to (3% nitrogen, 97% hydrogen). The results of these studies in our test stand will be presented in this paper.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] SUPPRESSION OF PROPAGATING TE MODES IN THE FNAL ANTIPROTON SOURCE STOCHASTIC BEAM COOLING SYSTEM
    BARRY, WC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (05) : 2424 - 2426
  • [42] Dependence of the beam current measurement on the operation parameters of the microwave ion source
    Dae-il Kim
    Hyeok-Jung Kwon
    Han-Sung Kim
    Kyung-Tae Seol
    Yong-Sub Cho
    Journal of the Korean Physical Society, 2013, 62 : 1591 - 1594
  • [43] BROAD BEAM HIGH AVERAGE CURRENT METAL-ION SOURCE
    ZHANG, XJ
    ZHOU, FS
    ZHANG, HX
    ZHANG, SJ
    LI, Q
    HAN, Z
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (04): : 2431 - 2433
  • [44] DEVELOPMENT OF HIGH-CURRENT METAL-ION BEAM SOURCE
    INAMI, H
    FUKUMARU, F
    INOUCHI, Y
    SATO, D
    TANAKA, K
    MATSUNAGA, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 37-8 : 198 - 200
  • [45] Dependence of the beam current measurement on the operation parameters of the microwave ion source
    Kim, Dae-il
    Kwon, Hyeok-Jung
    Kim, Han-Sung
    Seol, Kyung-Tae
    Cho, Yong-Sub
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 62 (11) : 1591 - 1594
  • [46] ION-BEAM ENHANCED MAGNETRON REACTIVE ION ETCHING
    CHINN, JD
    APPLIED PHYSICS LETTERS, 1987, 51 (24) : 2007 - 2009
  • [47] Identification and reduction of acoustic-noise influence on focused ion beam (FIB)
    Pluska, M.
    Czerwinski, A.
    Wzorek, M.
    Juchniewicz, M.
    Katcki, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 348 : 106 - 110
  • [48] First Test of BNL Electron Beam Ion Source with High Current Density Electron Beam
    Pikin, Alexander
    Alessi, James G.
    Beebe, Edward N.
    Shornikov, Andrey
    Mertzig, Robert
    Wenander, Fredrik
    Scrivens, Richard
    PROCEEDINGS OF THE XII INTERNATIONAL SYMPOSIUM ON ELECTRON BEAM ION SOURCES AND TRAPS, 2015, 1640
  • [49] MAGNETRON ION-SOURCE FOR ANTIMONY IONS
    JOKIC, T
    JOSIMOV, G
    TOSIC, MM
    GONCIC, B
    JURELA, Z
    NUCLEAR INSTRUMENTS & METHODS, 1980, 178 (2-3): : 309 - 310
  • [50] INFLUENCE OF THE INHOMOGENEITY OF AN ELECTRON-BEAM ON THE STABILITY OF THE ION CURRENT IN AN ION-SOURCE WITH AN EFFUSION MOLECULAR-BEAM
    MARCINKOWSKA, E
    MICHALAK, L
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 128 (03): : 157 - 164