A modified three-dimensional numerical model for predicting the short-time-step performance of borehole ground heat exchangers

被引:18
|
作者
Lee, C. K. [1 ]
机构
[1] City Univ Hong Kong, Div Bldg Sci & Technol, Kowloon Tong, Hong Kong, Peoples R China
关键词
Ground-source heat pump; Ground heat exchanger; Borehole; U-tube; Short-time-step; GEOTHERMAL SYSTEMS; SIMULATION; VALIDATION; FLOW;
D O I
10.1016/j.renene.2015.10.052
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A modified three-dimensional numerical model for the borehole ground heat exchangers was proposed which took into account the effect of grout thermal capacitance and fluid circulation period inside the U-tube in a short-time-step analysis. The present model was validated by experimental data from others. It was found that the fluid temperature along the U-tube changed abruptly at the interface between the entering and the existing fluid inside the borehole. Before the entering fluid travelled to the bottom of the U-tube, the borehole was only partly-loaded. The difference in the simulated fluid leaving temperatures between the long- and short-time-step approaches could be up to 3 degrees C when a periodic intermittent load, common during the low-load season, was applied. This implied that a short-time-step model should be used in a long-term dynamic system simulation. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:618 / 627
页数:10
相关论文
共 50 条