The difference in histological yield between 19G EUS-FNA and EUS-fine-needle biopsy needles

被引:23
|
作者
Ang, Tiing Leong [1 ]
Li, James Weiquan [1 ]
Kwek, Andrew Boon Eu [1 ]
Thurairajah, Prem Harichander [1 ]
Wang, Lai Mun [2 ]
机构
[1] Changi Gen Hosp, Dept Gastroenterol & Hepatol, 2 Simei St 3, Singapore 529889, Singapore
[2] Changi Gen Hosp, Dept Lab Med, Singapore, Singapore
关键词
Aspiration; biopsy; cytology; endoscopic ultrasound; histology; needles; GUIDED TISSUE ACQUISITION; DIAGNOSTIC-ACCURACY; SOLID LESIONS; ASPIRATION; MULTICENTER; IMPROVE; TRIAL;
D O I
10.4103/eus.eus_12_19
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Objective: EUS-guided fine-needle biopsy (EUS-FNB) with acquisition of tissue core is possible with the use of 19G fine-needle aspiration (FNA) and dedicated biopsy needles. Published data of direct comparisons between biopsy needles are more limited compared to the abundant data comparing EUS-FNA with EUS-FNB. We performed a retrospective study - to determine the difference in histologic 3, field between 19G FNA needle and EUS-FNB needles in patients with solid masses. Materials and Methods: Consecutive patients who underwent EUS-FNB of solid masses from January 2014 to July 2018 were identified from a database. The difference in histologic), yield between needles w as analyzed. Results: A total of 159 patients underwent 179 EU S-FNB procedures (median of 2 needle passes 'range: 1-41). The use of 19G FNA, 19G, 20G. and 22G FNB needles allowed acquisition of a histologic core in 67.4% (29/43). 72.5% (29/40). 82.1% (46/56). and 75.9% (22/29), respectively (P = 0.368). A significant difference in the 3, yield of histologic core was detected when 19G FNA needle was compared with 22G Acquire (TM) FNB needle (67.4%[29/43] vs 94.1% [16/17], P = 0.032). The presence of histologic core was significantly - associated with a positive diagnosis (95.6% vs. 30.2%. P < 0.0001). Conclusion: EU S-FNB with acquisition of histologic core improved the diagnostic), yield. Dedicated FNB needles appeared to achieve a higher yield of histologic core compared to 19G FNA needles.
引用
收藏
页码:255 / 260
页数:6
相关论文
共 50 条
  • [1] Prospective comparison of endoscopic ultrasound guided 22G fine needle aspiration (EUS-FNA) with 19G trucut needle biopsy (EUS-TNB)
    Pereira, SP
    Falzon, M
    Kocjan, G
    Novelli, M
    [J]. GUT, 2003, 52 : A26 - A26
  • [2] is there a difference in diagnostic yield between 22g and 25g needles in endoscopic ultrasound guided fine-needle aspiration (EUS-FNA) of solid lesions?
    Conway, J.
    Kundu, S.
    Mishra, G.
    Stefanescu, S.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2009, 69 (02) : S248 - S248
  • [3] Objective evaluation of the resistance forces of 22-gauge EUS-FNA and fine-needle biopsy needles
    Matsunami, Yukitoshi
    Itoi, Takao
    Tsuchiya, Takayoshi
    Ishii, Kentaro
    Tanaka, Reina
    Tonozuka, Ryosuke
    Mukai, Shuntaro
    Nagai, Kazumasa
    Yamamoto, Kenjiro
    Asai, Yasutsugu
    Kurosawa, Takashi
    Kojima, Hiroyuki
    Minami, Hirohito
    Homma, Toshihiro
    Joyama, Eri
    Sofuni, Atsushi
    [J]. ENDOSCOPIC ULTRASOUND, 2023, 12 (02) : 251 - 258
  • [4] EUS-FNA giving way to fine-needle biopsy: Is it time to retire your old trusted needles?
    El Hajj, Ihab I.
    Al-Haddad, Mohammad
    [J]. GASTROINTESTINAL ENDOSCOPY, 2018, 87 (06) : 1439 - 1442
  • [5] Comparison between fine needle aspiration (FNA) directed CT biopsy (FNA-CT-Bx) and EUS-guided FNA (EUS-FNA) for pancreatic carcinoma.
    Wied, K
    Erickson, RA
    Neese, PA
    Schoolar, EJ
    Maupin, B
    Speights, VO
    SayageRabie, L
    [J]. GASTROINTESTINAL ENDOSCOPY, 1997, 45 (04) : 641 - 641
  • [6] An international, multi-institution survey on performing EUS-FNA and fine needle biopsy
    Guo, Jintao
    Sahai, Anand, V
    Teoh, Anthony
    Arcidiacono, Paolo Giorgio
    Larghi, Alberto
    Saftoiu, Adrian
    Siddiqui, Ali A.
    Arturo Arias, Brenda Lucia
    Jenssen, Christian
    Adler, Douglas G.
    Lakhtakia, Sundeep
    Seo, Dong-Wan
    Itokawa, Fumihide
    Giovannini, Marc
    Mishra, Girish
    Sabbagh, Luis
    Irisawa, Atsushi
    Iglesias-Garcia, Julio
    Poley, Jan Werner
    Vila, Juan J.
    Jesse, Lachter
    Kubota, Kensuke
    Kalaitzakis, Evangelos
    Kida, Mitsuhiro
    El-Nady, Mohamed
    Mukai, Sh Untaro
    Ogura, Takeshi
    Fusaroli, Pietro
    Vilmann, Peter
    Rai, Praveer
    Nguyen, Nam Q.
    Ponnudurai, Ryan
    Achanta, Chalapathi Rao
    Baron, Todd H.
    Yasuda, Ichiro
    Wang, Hsiu-Po
    Hu, Jinlong
    Duan, Bowen
    Bhutani, Manoop S.
    Sun, Siyu
    [J]. ENDOSCOPIC ULTRASOUND, 2020, 9 (05) : 319 - +
  • [7] Diagnostic Yield of a Conventional Endoscopic Ultrasound-Fine Needle Aspiration (EUS-FNA) and Two Endoscopic Ultrasound-Fine Needle Biopsy (EUS-FNB) Needles: A Single-Center, Retrospective Study
    Iqbal, Fareha
    Aditi, Anupam
    Huang, Brian L.
    Ballonado, Ardene
    Hassan, Muhammad
    Arain, Mustafa A.
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2018, 113 : S442 - S442
  • [8] Diagnostic Yield of a Conventional Endoscopic Ultrasound-Fine Needle Aspiration (EUS-FNA) and Two Endoscopic Fine Needle Biopsy (EUS-FNB) Needles in Solid Lesions and Pancreatic Cancer: A Single Center, Retrospective Study
    Iqbal, F.
    Miranda, J.
    Aditi, A.
    Huang, B.
    Ballonado, A.
    Hassan, M.
    Arain, M.
    [J]. PANCREAS, 2018, 47 (10) : 1394 - 1395
  • [9] Determinants of number of fine needle aspiration (FNA) passes in EUS-guided FNA (EUS-FNA) for pancreatic malignancies.
    Erickson, RA
    Sayage-Rabie, L
    Beissner, RS
    [J]. GASTROINTESTINAL ENDOSCOPY, 1998, 47 (04) : AB146 - AB146
  • [10] TO COMPARE THE TISSUE DIAGNOSTIC YIELD OF SOLID LESION BIOPSIES BASED ON THE HISTOPATHOLOGICAL ANALYSIS OF ENDOSCOPIC ULTRASOUND-GUIDED FINE NEEDLE ASPIRATION (EUS-FNA) SAMPLES PRODUCED BY THE 19G PROCORE NEEDLE, STANDARD 19G NEEDLE AND 22G PROCORE NEEDLE
    Gupta, Mahesh Kumar
    [J]. GUT, 2020, 69 : A30 - A30