Fluid-structure interaction and structural analyses using a comprehensive mitral valve model with 3D chordal structure

被引:30
|
作者
Toma, Milan [1 ,2 ]
Einstein, Daniel R. [3 ]
Bloodworth, Charles H. [1 ,2 ]
Cochran, Richard P. [4 ]
Yoganathan, Ajit P. [1 ,2 ]
Kunzelman, Karyn S. [4 ]
机构
[1] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Technol Enterprise Pk,Suite 200,387 Technol, Atlanta, GA 30313 USA
[2] Emory Univ, Technol Enterprise Pk,Suite 200,387 Technol, Atlanta, GA 30313 USA
[3] St Martins Univ, Dept Mech Engn, 5000 Abbey Way SE, Lacey, WA 98503 USA
[4] Univ Maine, Dept Mech Engn, 219 Boardman Hall, Orono, ME 04469 USA
关键词
fluid-structure interaction; mitral valve; forces; comprehensive computational model; papillary muscle; chordal structure; chordae tendineae; FINITE-ELEMENT MODEL; PAPILLARY-MUSCLE; REPLACEMENT; REGURGITATION; DILATATION; TENDINEAE; DYNAMICS; STRESSES; SUTURE;
D O I
10.1002/cnm.2815
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Over the years, three-dimensional models of the mitral valve have generally been organized around a simplified anatomy. Leaflets have been typically modeled as membranes, tethered to discrete chordae typically modeled as one-dimensional, non-linear cables. Yet, recent, high-resolution medical images have revealed that there is no clear boundary between the chordae and the leaflets. In fact, the mitral valve has been revealed to be more of a webbed structure whose architecture is continuous with the chordae and their extensions into the leaflets. Such detailed images can serve as the basis of anatomically accurate, subject-specific models, wherein the entire valve is modeled with solid elements that more faithfully represent the chordae, the leaflets, and the transition between the two. These models have the potential to enhance our understanding of mitral valve mechanics and to re-examine the role of the mitral valve chordae, which heretofore have been considered to be invisible' to the fluid and to be of secondary importance to the leaflets. However, these new models also require a rethinking of modeling assumptions. In this study, we examine the conventional practice of loading the leaflets only and not the chordae in order to study the structural response of the mitral valve apparatus. Specifically, we demonstrate that fully resolved 3D models of the mitral valve require a fluid-structure interaction analysis to correctly load the valve even in the case of quasi-static mechanics. While a fluid-structure interaction mode is still more computationally expensive than a structural-only model, we also show that advances in GPU computing have made such models tractable. Copyright (c) 2016 John Wiley & Sons, Ltd.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] 3D fluid-structure interaction simulation of an hydrofoil at low Reynolds number
    Salmon, Fabien
    Chatellier, Ludovic
    JOURNAL OF FLUIDS AND STRUCTURES, 2022, 111
  • [42] Fluid-structure interaction of Brezina arch dam: 3D modal analysis
    Amina, Tahar Berrabah
    Mohamed, Belharizi
    Andre, Laulusa
    Abdelmalek, Bekkouche
    ENGINEERING STRUCTURES, 2015, 84 : 19 - 28
  • [43] A fully coupled fluid-structure interaction model of the secondary lymphatic valve
    Wilson, John T.
    Edgar, Lowell T.
    Prabhakar, Saurabh
    Horner, Marc
    van Loon, Raoul
    Moore, James E.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2018, 21 (16) : 813 - 823
  • [44] Validation and Extension of a Fluid-Structure Interaction Model of the Healthy Aortic Valve
    Tango, Anna Maria
    Salmonsmith, Jacob
    Ducci, Andrea
    Burriesci, Gaetano
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2018, 9 (04) : 739 - 751
  • [45] A design-based model of the aortic valve for fluid-structure interaction
    Alexander D. Kaiser
    Rohan Shad
    William Hiesinger
    Alison L. Marsden
    Biomechanics and Modeling in Mechanobiology, 2021, 20 : 2413 - 2435
  • [46] Validation of a fluid-structure interaction model for a bileaflet mechanical heart valve
    Forsythe, Neil
    Mueller, Jens-Dominik
    INTERNATIONAL JOURNAL OF COMPUTATIONAL FLUID DYNAMICS, 2008, 22 (08) : 541 - 553
  • [47] A design-based model of the aortic valve for fluid-structure interaction
    Kaiser, Alexander D.
    Shad, Rohan
    Hiesinger, William
    Marsden, Alison L.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2021, 20 (06) : 2413 - 2435
  • [48] Fluid-structure interactions of the mitral valve and left heart: Comprehensive strategies, past, present and future
    Einstein, Daniel R.
    Del Pin, Facundo
    Jiao, Xiangmin
    Kuprat, Andrew P.
    Carson, James P.
    Kunzelman, Karyn S.
    Cochran, Richard P.
    Guccione, Julius M.
    Ratcliffe, Mark B.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2010, 26 (3-4) : 348 - 380
  • [49] Modeling of aortic valve stenosis using fluid-structure interaction method
    Ghasemi Pour, Mohammad Javad
    Hassani, Kamran
    Khayat, Morteza
    Etemadi Haghighi, Shahram
    PERFUSION-UK, 2022, 37 (04): : 367 - 376
  • [50] MAXIMAL-IN-TIME EXISTENCE AND UNIQUENESS OF STRONG SOLUTION OF A 3D FLUID-STRUCTURE INTERACTION MODEL
    Maity, Debayan
    Raymond, Jean-Pierre
    Roy, Arnab
    SIAM JOURNAL ON MATHEMATICAL ANALYSIS, 2020, 52 (06) : 6338 - 6378