Electrochemical glucose sensor based on the glucose oxidase entrapped in chitosan immobilized onto laser-processed Au-Ti electrode

被引:60
|
作者
Lipinska, Wiktoria [1 ]
Siuzdak, Katarzyna [1 ]
Karczewski, Jakub [2 ]
Dolega, Anna [3 ]
Grochowska, Katarzyna [1 ]
机构
[1] Polish Acad Sci, Szewalski Inst Fluid Flow Machinery, Ctr Plasma & Laser Engn, Fiszera 14 St, PL-80231 Gdansk, Poland
[2] Gdansk Univ Technol, Fac Appl Phys & Math, Narutowicza 11-12 St, PL-80233 Gdansk, Poland
[3] Gdansk Univ Technol, Fac Chem, Dept Inorgan Chem, Narutowicza 11-12 St, PL-80233 Gdansk, Poland
关键词
Enzyme immobilization; Chitosan; Laser dewetted Au nanoparticles; Glucose sensing; Electrochemical biosensor; CARBON NANOTUBES; ENZYME; FILMS; NANOPARTICLES; PERFORMANCE; NANOWIRES; COMPOSITE; PLATFORM;
D O I
10.1016/j.snb.2020.129409
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glucose is essential to keep the human body in well order. Therefore, the control of its level is of key importance. The study on novel electrode material composed of structured titanium foil with embedded Au nanoparticles and modified with chitosan with entrapped glucose oxidase is presented. In the first step, Ti foil undergoes anodization followed by chemical etching resulting in formation of homogenously distributed inverted caps of diameter of 85 nm. After deposition of thin Au layer, the rapid and well optimized laser dewetting is applied to form Au nanoparticles of size limited by the dimensions of cavities. Finally, the surface is modified using enzyme and chitosan mixture. To confirm the successful immobilization of glucose oxidase FT-IR analysis was performed. The response of electrodes were tested towards glucose in 0.1 M PBS containing most different interference compounds and biological fluids. It is proven that prepared material exhibits excellent performance for glucose detection with a wide linear range of 0.04-15.05 and 15.05-40.00 mM, with sensitivity of 23.47 +/- 1.36 and 10.63 +/- 1.28 mu Acm(-2) mM(-1), respectively, and very low limit of detection 1.75 +/- 0.30 mu M. The perfect selectivity and stability promotes the material selection as the main biosensor component.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Glucose biosensor based on a platinum electrode modified with rhodium nanoparticles and with glucose oxidase immobilized on gold nanoparticles
    Guo, Xishan
    Liang, Bo
    Jian, Jinming
    Zhang, Yelei
    Ye, Xuesong
    MICROCHIMICA ACTA, 2014, 181 (5-6) : 519 - 525
  • [42] Direct Electron Transfer at a Glucose Oxidase–Chitosan-Modified Vulcan Carbon Paste Electrode for Electrochemical Biosensing of Glucose
    Sankararao Mutyala
    Jayaraman Mathiyarasu
    Applied Biochemistry and Biotechnology, 2014, 172 : 1517 - 1529
  • [43] Direct Electron Transfer at a Glucose Oxidase-Chitosan-Modified Vulcan Carbon Paste Electrode for Electrochemical Biosensing of Glucose
    Mutyala, Sankararao
    Mathiyarasu, Jayaraman
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2014, 172 (03) : 1517 - 1529
  • [44] Glucose biosensor based on glucose oxidase immobilized in sol–gel chitosan/silica hybrid composite film on Prussian blue modified glass carbon electrode
    Xue-Cai Tan
    Yuan-Xin Tian
    Pei-Xiang Cai
    Xiao-Yong Zou
    Analytical and Bioanalytical Chemistry, 2005, 381 : 500 - 507
  • [45] Amperometric glucose biosensor based on glucose oxidase immobilized over chitosan nanoparticles from gladius of Uroteuthis duvauceli
    Anusha, J. R.
    Raj, C. Justin
    Cho, Bo-Bae
    Fleming, Albin T.
    Yu, Kook-Hyun
    Kim, Byung Chul
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 215 : 536 - 543
  • [46] Glucose Sensor Based on Glucose Oxidase-Lipid LB Film Immobilized in Prussian Blue Layer
    Lee, Dong-Yun
    Kafi, A. K. M.
    Choi, Won-Suk
    Park, Sang-Hyun
    Kwon, Young-Soo
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2008, 8 (09) : 4543 - 4547
  • [47] Electrochemical Response of β-Galactosidase- and Glucose Oxidase-containing Microcapsule-immobilized Electrode
    Shitanda, Isao
    Itagaki, Masayuki
    Asano, Kaori
    CHEMISTRY LETTERS, 2012, 41 (05) : 533 - 534
  • [48] FLOW-INJECTION ANALYSIS OF GLUCOSE AT AN AMPEROMETRIC GLUCOSE SENSOR-BASED ON ELECTROCHEMICAL CODEPOSITION OF PALLADIUM AND GLUCOSE-OXIDASE ON A GLASSY-CARBON ELECTRODE
    CHI, QJ
    DONG, SJ
    ANALYTICA CHIMICA ACTA, 1993, 278 (01) : 17 - 23
  • [49] Logic Gate System with Three Outputs and Three Inputs Based on Switchable Electrocatalysis of Glucose by Glucose Oxidase Entrapped in Chitosan Films
    Liu, Shuang
    Wang, Lei
    Lian, Wenjing
    Liu, Hongyun
    Li, Chen-Zhong
    CHEMISTRY-AN ASIAN JOURNAL, 2015, 10 (01) : 225 - 230
  • [50] On-Chip Glucose Detection Based on Glucose Oxidase Immobilized on a Platinum-Modified, Gold Microband Electrode
    Madden, Julia
    Barrett, Colm
    Laffir, Fathima R.
    Thompson, Michael
    Galvin, Paul
    O' Riordan, Alan
    BIOSENSORS-BASEL, 2021, 11 (08):