Automated Breast Ultrasound for Ductal Pattern Reconstruction: Ground Truth File Generation and CADe Evaluation

被引:0
|
作者
Manousaki, D. [1 ]
Panagiotopoulou, A. [1 ]
Bizimi, V. [2 ]
Haynes, M. S. [3 ]
Love, S. [4 ]
Kallergi, M. [1 ]
机构
[1] TEIA, Dept Biomed Engn, Athens, Greece
[2] Univ Hosp Attikon, Radiol Dept 2, Athens, Greece
[3] JPL, Pasadena, CA USA
[4] Dr Susan Love Res Fdn, Encino, CA USA
关键词
WOMEN;
D O I
10.1088/1742-6596/931/1/012037
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was the generation of ground truth files (GTFs) of the breast ducts from 3D images of the Invenia (TM) Automated Breast Ultrasound System (ABUS) system (GE Healthcare, Little Chalfont, UK) and the application of these GTFs for the optimization of the imaging protocol and the evaluation of a computer aided detection (CADe) algorithm developed for automated duct detection. Six lactating, nursing volunteers were scanned with the ABUS before and right after breastfeeding their infants. An expert in breast ultrasound generated rough outlines of the milk-filled ducts in the transaxial slices of all image volumes and the final GTFs were created by using thresholding and smoothing tools in ImageJ. In addition, a CADe algorithm automatically segmented duct like areas and its results were compared to the expert's GTFs by estimating true positive fraction (TPF) or % overlap. The CADe output differed significantly from the expert's but both detected a smaller than expected volume of the ducts due to insufficient contrast (ducts were partially filled with milk), discontinuities, and artifacts. GTFs were used to modify the imaging protocol and improve the CADe method. In conclusion, electronic GTFs provide a valuable tool in the optimization of a tomographic imaging system, the imaging protocol, and the CADe algorithms. Their generation, however, is an extremely time consuming, strenuous process, particularly for multi-slice examinations, and alternatives based on phantoms or simulations are highly desirable.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] ACCURACY OF AN AUTOMATED BREAST VOLUME ULTRASOUND SYSTEM FOR ASSESSMENT OF THE PRE-OPERATIVE EXTENT OF PURE DUCTAL CARCINOMA IN SITU: COMPARISON WITH A CONVENTIONAL HANDHELD ULTRASOUND EXAMINATION
    Li, Na
    Jiang, Yu-Xin
    Zhu, Qing-Li
    Zhang, Jing
    Dai, Qing
    Liu, He
    Yang, Qian
    Wang, Hong-Yan
    Lai, Xing-Jian
    Sun, Qiang
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (12): : 2255 - 2263
  • [42] Evaluation of a second-generation monoenergetic reconstruction algorithm for lesion contrast and venous invasion in pancreatic ductal adenocarcinomas
    Zhuo, S. -Q.
    Ma, H. -L.
    Liu, L. -Z
    Ruan, G. -Y.
    Xie, C. -B.
    Huang, W. -J.
    Yang, G. -J.
    Li, Z. -P.
    Zeng, S. -H.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2019, 23 (21) : 9341 - 9350
  • [43] Evaluation of the FUSION-X-US-II prototype to combine automated breast ultrasound and tomosynthesis
    Benedikt Schäfgen
    Marija Juskic
    Marcus Radicke
    Madeleine Hertel
    Richard Barr
    André Pfob
    Riku Togawa
    Juliane Nees
    Alexandra von Au
    Sarah Fastner
    Aba Harcos
    Christina Gomez
    Anne Stieber
    Fabian Riedel
    André Hennigs
    Christof Sohn
    Joerg Heil
    Michael Golatta
    European Radiology, 2021, 31 : 3712 - 3720
  • [44] Evaluation of the FUSION-X-US-II prototype to combine automated breast ultrasound and tomosynthesis
    Schaefgen, Benedikt
    Juskic, Marija
    Radicke, Marcus
    Hertel, Madeleine
    Barr, Richard
    Pfob, Andre
    Togawa, Riku
    Nees, Juliane
    von Au, Alexandra
    Fastner, Sarah
    Harcos, Aba
    Gomez, Christina
    Stieber, Anne
    Riedel, Fabian
    Hennigs, Andre
    Sohn, Christof
    Heil, Joerg
    Golatta, Michael
    EUROPEAN RADIOLOGY, 2021, 31 (06) : 3712 - 3720
  • [45] Clinical and ultrasound evaluation of donor site morbidity after tram-flap for breast reconstruction
    Benditte-Klepetko, H
    Sommer, O
    Steinbach, R
    Czembirek, H
    Deutinger, M
    MICROSURGERY, 2004, 24 (03) : 174 - 181
  • [46] Preliminary evaluation of an automated autoencoder-UNet pipeline for chemical image segmentation and compression with reference to serial ground truth pathology
    Rafsanjani, Moh Rifqi
    McBrien, Thomas
    Jirstrom, Karin
    Rahman, Arman
    Prehn, Jochen H.
    Gallagher, William
    Meade, Aidan D.
    DATA SCIENCE FOR PHOTONICS AND BIOPHOTONICS, 2024, 13011
  • [47] IVL-SYNTHSFM-v2: A synthetic dataset with exact ground truth for the evaluation of 3D reconstruction pipelines
    Marelli, Davide
    Bianco, Simone
    Ciocca, Gianluigi
    DATA IN BRIEF, 2020, 29
  • [48] Computerized Ultrasound Risk Evaluation (CURIE) system: Development of combined transmission and reflection ultrasound with new reconstruction algorithms for breast imaging
    Littrup, PJ
    Duric, N
    Azevedo, S
    Chambers, D
    Candy, JV
    Johnson, S
    Auner, G
    Rather, J
    Holsapple, ET
    ACOUSTICAL IMAGING, VOL 26, 2002, 26 : 175 - 182
  • [49] First Evaluation of the Diagnostic Accuracy of an Automated 3D Ultrasound System in a Breast Screening Setting
    Stoeblen, Frank
    Landt, Solveig
    Stelkens-Gebhardt, Ruth
    Sehouli, Jalid
    Rezai, Mahdi
    Kuemmel, Sherko
    ANTICANCER RESEARCH, 2011, 31 (08) : 2569 - 2574
  • [50] Evaluation of a pipeline for simulation, reconstruction, and classification in ultrasound-aided diffuse optical tomography of breast tumors
    Di Sciacca, Giuseppe
    Maffeis, Giulia
    Farina, Andrea
    Dalla Mora, Alberto
    Pifferi, Antonio
    Taroni, Paola
    Arridge, Simon
    JOURNAL OF BIOMEDICAL OPTICS, 2022, 27 (03) : 036003