PEAK LOAD REDUCTION OF DISTRICT HEATING BY CONTROL OF INDOOR PUBLIC SWIMMING POOL

被引:0
|
作者
Kim, Ok [1 ]
Knudsen, Michael Dahl [1 ]
Petersen, Steffen [1 ]
机构
[1] Aarhus Univ, Aarhus, Denmark
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In Denmark, the first district heating (DH) plant was built in 1903 and today about 64% of all residential buildings are connected to DH. The demand for DH is steadily increasing in and around major cities as more buildings are built for the increasing population. As a result, larger peak demands occur that might exceed the current DH production and/ or distribution capacities. To avoid or minimise this, existing thermal capacities in the city could be utilized to shift loads from peak to nonpeak periods and hence reduce or avoid the rather large public infrastructure investments needed to expand the existing DH capacities. Such existing capacities could be for example design containers, swimming pools, underground aquifers, soils, and lakes. This study investigates the potential of applying a public indoor swimming pool for load shifting. Simulations of alternative control scenarios were performed in EnergyPlus which effectively reduced the peak demand of a district heating area.
引用
收藏
页码:594 / 599
页数:6
相关论文
共 50 条
  • [31] Control rod drop-time reduction in typical swimming pool research reactors
    Afrakati, M. R. Salmanpour Paean
    Gharib, M.
    Mirvakili, S. M.
    PROGRESS IN NUCLEAR ENERGY, 2018, 106 : 146 - 152
  • [32] Development of an intelligent building controller to mitigate indoor thermal dissatisfaction and peak energy demands in a district heating system
    Ahn, Jonghoon
    Cho, Soolyeon
    BUILDING AND ENVIRONMENT, 2017, 124 : 57 - 68
  • [33] Economic analysis for district heating system with gas-fired peak load boiler in secondary network
    Zheng, Xuejing
    You, Shijun
    Zhu, Yanlin
    Niu, Runping
    Dong, Shuyun
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 161 - 164
  • [34] Value analysis of district heating system with gas-fired peak load boiler in secondary network
    郑雪晶
    穆振英
    Journal of Central South University, 2009, 16 (S1) : 178 - 182
  • [35] Value analysis of district heating system with gas-fired peak load boiler in secondary network
    Zheng Xue-jing
    Mu Zhen-ying
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2009, 16 : 178 - 182
  • [36] Low-emission district heating: Peak-load power plant in Vienna is fit for the future
    Zehrer, Fabian
    Euroheat and Power/Fernwarme International, 2021, 20 (11-12): : 12 - 15
  • [37] Dynamic simulation and thermo-economic analysis of a PhotoVoltaic/Thermal collector heating system for an indoor-outdoor swimming pool
    Buonomano, Annamaria
    De Luca, Giuseppina
    Figaj, Rafal Damian
    Vanoli, Laura
    ENERGY CONVERSION AND MANAGEMENT, 2015, 99 : 176 - 192
  • [38] Study of peak load condition during indoor climate control for Roorkee weather conditions
    Sah, Shammy Kumar
    Murugesan, Krishnan
    Rajasekar, Elagovan
    PROCEEDINGS OF THE 25TH NATIONAL AND 3RD INTERNATIONAL ISHMT-ASTFE HEAT AND MASS TRANSFER CONFERENCE, IHMTC 2019, 2019,
  • [39] Design and development of a public leisure center made up of tropical garden and an indoor swimming pool in the City of Valencia [Spain]
    Fernandez Lacruz, E.
    TUBULAR STRUCTURES XII, 2009, : 491 - +
  • [40] OPERATION AND LOAD OF A SEA-WATER SWIMMING POOL WITH CONTINUOUS WATER CIRCULATION FROM A PUBLIC HEALTH STANDPOINT
    HAVEMEISTER, G
    ARCHIV FUR HYGIENE UND BAKTERIOLOGIE, 1969, 153 (04): : 298 - +