Effect of tissue composition on dose distribution in brachytherapy with various photon emitting sources

被引:16
|
作者
Ghorbani, Mahdi [1 ]
Salahshour, Fateme [2 ]
Haghparast, Abbas [2 ]
Moghaddas, Toktam Ahmadi [2 ]
Knaup, Courtney [3 ]
机构
[1] Mashhad Univ Med Sci, Fac Med, Med Phys Res Ctr, Mashhad, Iran
[2] Kermanshah Univ Med Sci, Fac Med, Med Phys & Med Engn Dept, Kermanshah, Iran
[3] Comprehens Canc Ctr Nevada, Las Vegas, NV USA
关键词
brachytherapy; ICRU; photon emitting sources; relative dose; soft tissue; MONTE-CARLO CHARACTERIZATION; IR-192; BRACHYTHERAPY; DOSIMETRY PARAMETERS; PD-103; YB-169; CO-60; WATER; UPDATE; I-125; LUNG;
D O I
10.5114/jcb.2014.42024
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study is to compare the dose in various soft tissues in brachytherapy with photon emitting sources. Material and methods: Pd-103, I-125, Yb-169, Ir-192 brachytherapy sources were simulated with MCNPX Monte Carlo code, and their dose rate constant and radial dose function were compared with the published data. A spherical phantom with 50 cm radius was simulated and the dose at various radial distances in adipose tissue, breast tissue, 4-component soft tissue, brain (grey/white matter), muscle (skeletal), lung tissue, blood (whole), 9-component soft tissue, and water were calculated. The absolute dose and relative dose difference with respect to 9-component soft tissue was obtained for various materials, sources, and distances. Results: There was good agreement between the dosimetric parameters of the sources and the published data. Adipose tissue, breast tissue, 4-component soft tissue, and water showed the greatest difference in dose relative to the dose to the 9-component soft tissue. The other soft tissues showed lower dose differences. The dose difference was also higher for Pd-103 source than for I-125, Yb-169, and Ir-192 sources. Furthermore, greater distances from the source had higher relative dose differences and the effect can be justified due to the change in photon spectrum (softening or hardening) as photons traverse the phantom material. Conclusions: The ignorance of soft tissue characteristics (density, composition, etc.) by treatment planning systems incorporates a significant error in dose delivery to the patient in brachytherapy with photon sources. The error depends on the type of soft tissue, brachytherapy source, as well as the distance from the source.
引用
收藏
页码:54 / 67
页数:14
相关论文
共 50 条
  • [21] Effect of calcium on dose distribution in intravascular brachytherapy
    Sherman, W
    Ravi, K
    Fox, J
    Reimers, C
    Fan, P
    Chiu-Tsao, S
    EUROPEAN HEART JOURNAL, 2000, 21 : 398 - 398
  • [22] Dose to tissue medium or water cavities as surrogate for the dose to cell nuclei at brachytherapy photon energies
    Enger, Shirin A.
    Ahnesjo, Anders
    Verhaegen, Frank
    Beaulieu, Luc
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (14): : 4489 - 4500
  • [23] A DOSIMETRIC UNCERTAINTY ANALYSIS FOR PHOTON-EMITTING BRACHYTHERAPY SOURCES BY THE AAPM AND GEC-ESTRO
    DeWerd, L.
    Ibbott, G.
    Meigooni, A.
    Mitch, M.
    Rivard, M.
    Stump, K.
    Thomadsen, B.
    Venselaar, J.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S574 - S574
  • [24] Endovascular brachytherapy: Dosimetry and dose-area analysis of various radiation sources
    Boeing N.
    Geoghegan S.
    Ebert M.A.
    Ebert, M.A. (Martin.Ebert@health.wa.gov.au), 2001, Australasian Coll. of Phys. Scientists and Engineers (24): : 63 - 70
  • [25] EGSnrc Monte Carlo calculated dose distribution around brachytherapy sources
    Tuan, Hoang
    Minh Phuoc Dang
    NUCLEAR MEDICINE AND BIOLOGY, 2022, 108 : S175 - S176
  • [26] Effect of calcium on dose distribution in intravascular brachytherapy.
    Fan, P
    Chiu-Tsao, S
    Ravi, K
    Sherman, W
    Pisch, J
    Harrison, LB
    Tsao, HS
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (6A): : 3P - 3P
  • [27] Statistical distribution of strengths for various models of low energy permanent brachytherapy sources
    Butler, W.
    Bouffard, M.
    Hines, A.
    Merrick, G.
    MEDICAL PHYSICS, 2007, 34 (06) : 2490 - 2490
  • [28] The difference of scoring dose to water or tissues in Monte Carlo dose calculations for low energy brachytherapy photon sources
    Landry, Guillaume
    Reniers, Brigitte
    Pignol, Jean-Philippe
    Beaulieu, Luc
    Verhaegen, Frank
    MEDICAL PHYSICS, 2011, 38 (03) : 1526 - 1533
  • [29] EFFECT OF TISSUE INHOMOGENEITY ON DOSE DISTRIBUTION OF POINT SOURCES OF LOW-ENERGY ELECTRONS
    KWOK, CS
    BIALOBZYSKI, PJ
    YU, SK
    PRESTWICH, WV
    MEDICAL PHYSICS, 1990, 17 (05) : 786 - 793
  • [30] Neutron Energy and Dose Considerations of Cf-252 Brachytherapy Sources for Various Geometries
    Giantsoudi, D.
    Liu, Y.
    Diaz, A.
    Mavroidis, P.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2008, 35 (06)