Effect of Osmotherapy on Optic Nerve Sheath Diameter in Patients with Increased Intracranial Pressure

被引:62
|
作者
Launey, Yoann [1 ,2 ,3 ]
Nesseler, Nicolas [1 ,2 ,3 ]
Le Maguet, Pascale [1 ]
Malledant, Yannick [1 ,2 ,3 ]
Seguin, Philippe [1 ,2 ,3 ]
机构
[1] Hop Pontchaillou, CHU Rennes, Dept Anesthesie Reanimat, F-35033 Rennes, France
[2] INSERM, U991, Rennes, France
[3] Univ Rennes 1, Rennes, France
关键词
intracranial hypertension; adult brain injury; optic nerve sheath diameter; osmotherapy; TRANSORBITAL SONOGRAPHIC EVALUATION; OCULAR SONOGRAPHY; ULTRASOUND; HYPERTENSION; ULTRASONOGRAPHY; FUNDAMENTALS; MANAGEMENT; EXPANSION; ACCURACY;
D O I
10.1089/neu.2012.2829
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The measurement of ocular nerve sheath diameter (ONSD) via ocular ultrasound scanning is a recent non-invasive method for intracranial pressure (ICP) assessment. Few clinical studies have assessed ONSD variations during osmotherapy for the treatment of sustained increased ICP episodes. The aim of our study was to determine the rate of ONSD variation after mannitol administration for increased ICP episodes. We consecutively included in a prospective, observational study, the patients who had severe acute brain injury and monitored with an invasive ICP monitor. For each episode of sustained elevated ICP, the ONSD was measured in the right and left eye with a 7.5-MHz echography probe, and the mean value was reported. Simultaneously, ICP and cerebral perfusion pressure (CPP) were recorded. All measurements were performed just before and 20 minutes following a 20% mannitol infusion. Data were expressed as medians and interquartile ranges. Thirteen patients were included and analysed (traumatic brain injury, n=10; subarachnoid haemorrhage, n=3). The median value of the mannitol dose infused was 0.54 g/kg (0.49-0.80 g/kg). In all cases, the ONSD was greater than 5.8 mm before osmotherapy. The ONSD significantly decreased after mannitol infusion from 6.3 (6.1-6.7) to 5. mm (5.5-6.3) (p=0.0007). Concomitantly, the intracranial pressure decreased from 35 (32-41) to 25 (22-29) mmHg (p=0.001) and the CPP increased from 47 (50-60) to 66 (59-69) mmHg (p=0.003). The variations of ONSD appear to be an interesting parameter to evaluate the efficacy of osmotherapy for elevated ICP episodes in patients with acute brain injury.
引用
收藏
页码:984 / 988
页数:5
相关论文
共 50 条
  • [21] Bedside Sonographic Measurement of Optic Nerve Sheath Diameter as a Predictor of Increased Intracranial Pressure in Children
    Le, Audrey
    Hoehn, Mary Ellen
    Smith, Mary E.
    Spentzas, Thomas
    Schlappy, David
    Pershad, Jay
    ANNALS OF EMERGENCY MEDICINE, 2009, 53 (06) : 785 - 791
  • [22] Can optic nerve sheath diameter assess increased intracranial pressure in pneumoperitoneum and trendelenburg position?
    Kamhawy, Ghada A.
    Khamis, Fatma M.
    El-Said, Galal H.
    Hassan, Nada T.
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2019, 35 (01): : 80 - 87
  • [23] Bedside Optic Nerve Sheath Diameter Assessment in the Identification of Increased Intracranial Pressure in Suspected Idiopathic Intracranial Hypertension
    Irazuzta, Jose E.
    Brown, Martha E.
    Akhtar, Javed
    PEDIATRIC NEUROLOGY, 2016, 54 : 35 - 38
  • [24] Optic nerve sheath diameter correlates to intracranial pressure in spontaneous CSF leak patients
    Tilak, Ashwini M.
    Yang, Lydia C.
    Morgan, Jake
    Pena-Garcia, Jaime
    Thompson, Maxwell
    Burleson, Samuel
    Atkins, Amanda
    Sheehan, Delaney
    Cho, Do-Yeon
    Woodworth, Bradford A.
    Grayson, Jessica W.
    INTERNATIONAL FORUM OF ALLERGY & RHINOLOGY, 2023, 13 (08) : 1518 - 1524
  • [25] The association between intracranial pressure and optic nerve sheath diameter on patients with head trauma
    Celik, Kaan
    Demiryurek, Bekir Enes
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2021, 79 (10) : 879 - 885
  • [26] Is Optic Nerve Sheath Diameter a Reliable Proxy for Intracranial Pressure in Patients with Subarachnoid Hemorrhage?
    Neeraja Ajayan
    Unnikrishnan Prathapadas
    Ajay Prasad Hrishi
    Manikandan Sethuraman
    Neurocritical Care, 2020, 33 : 617 - 618
  • [27] Is Optic Nerve Sheath Diameter a Reliable Proxy for Intracranial Pressure in Patients with Subarachnoid Hemorrhage?
    Ajayan, Neeraja
    Prathapadas, Unnikrishnan
    Hrishi, Ajay Prasad
    Sethuraman, Manikandan
    NEUROCRITICAL CARE, 2020, 33 (02) : 617 - 618
  • [28] Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure
    Kimberly, Heidi Harbison
    Shah, Sachita
    Marill, Keith
    Noble, Vicki
    ACADEMIC EMERGENCY MEDICINE, 2008, 15 (02) : 201 - 204
  • [29] Measuring Optic Nerve Sheath Diameter as a Proxy for Intracranial Pressure Reply
    Wang, Li-juan
    Chen, Hong-xiu
    Xing, Ying-qi
    JAMA OPHTHALMOLOGY, 2018, 136 (11) : 1311 - 1312
  • [30] ULTRASONOGRAPHY OF OPTIC NERVE SHEATH DIAMETER (ONSD) FOR RAISED INTRACRANIAL PRESSURE
    Siddiqui, Naveed Ur Rehman
    CRITICAL CARE MEDICINE, 2018, 46 (01) : 397 - 397