Effect of Osmotherapy on Optic Nerve Sheath Diameter in Patients with Increased Intracranial Pressure

被引:62
|
作者
Launey, Yoann [1 ,2 ,3 ]
Nesseler, Nicolas [1 ,2 ,3 ]
Le Maguet, Pascale [1 ]
Malledant, Yannick [1 ,2 ,3 ]
Seguin, Philippe [1 ,2 ,3 ]
机构
[1] Hop Pontchaillou, CHU Rennes, Dept Anesthesie Reanimat, F-35033 Rennes, France
[2] INSERM, U991, Rennes, France
[3] Univ Rennes 1, Rennes, France
关键词
intracranial hypertension; adult brain injury; optic nerve sheath diameter; osmotherapy; TRANSORBITAL SONOGRAPHIC EVALUATION; OCULAR SONOGRAPHY; ULTRASOUND; HYPERTENSION; ULTRASONOGRAPHY; FUNDAMENTALS; MANAGEMENT; EXPANSION; ACCURACY;
D O I
10.1089/neu.2012.2829
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The measurement of ocular nerve sheath diameter (ONSD) via ocular ultrasound scanning is a recent non-invasive method for intracranial pressure (ICP) assessment. Few clinical studies have assessed ONSD variations during osmotherapy for the treatment of sustained increased ICP episodes. The aim of our study was to determine the rate of ONSD variation after mannitol administration for increased ICP episodes. We consecutively included in a prospective, observational study, the patients who had severe acute brain injury and monitored with an invasive ICP monitor. For each episode of sustained elevated ICP, the ONSD was measured in the right and left eye with a 7.5-MHz echography probe, and the mean value was reported. Simultaneously, ICP and cerebral perfusion pressure (CPP) were recorded. All measurements were performed just before and 20 minutes following a 20% mannitol infusion. Data were expressed as medians and interquartile ranges. Thirteen patients were included and analysed (traumatic brain injury, n=10; subarachnoid haemorrhage, n=3). The median value of the mannitol dose infused was 0.54 g/kg (0.49-0.80 g/kg). In all cases, the ONSD was greater than 5.8 mm before osmotherapy. The ONSD significantly decreased after mannitol infusion from 6.3 (6.1-6.7) to 5. mm (5.5-6.3) (p=0.0007). Concomitantly, the intracranial pressure decreased from 35 (32-41) to 25 (22-29) mmHg (p=0.001) and the CPP increased from 47 (50-60) to 66 (59-69) mmHg (p=0.003). The variations of ONSD appear to be an interesting parameter to evaluate the efficacy of osmotherapy for elevated ICP episodes in patients with acute brain injury.
引用
收藏
页码:984 / 988
页数:5
相关论文
共 50 条
  • [1] Effect of intracranial pressure on the diameter of the optic nerve sheath
    Watanabe, Arata
    Kinouchi, Hiroyuki
    Horikoshi, Toru
    Uchida, Mikito
    Ishigame, Keiichi
    JOURNAL OF NEUROSURGERY, 2008, 109 (02) : 255 - 258
  • [2] Optic Nerve Sheath Diameter Ultrasound and the Diagnosis of Increased Intracranial Pressure
    Hylkema, Christopher
    CRITICAL CARE NURSING CLINICS OF NORTH AMERICA, 2016, 28 (01) : 95 - +
  • [3] Measurement of Optic Nerve Sheath Diameter to Detect Increased Intracranial Pressure in Hypertensive Patients
    Dikmetas, Cesareddin
    Ergin, Mehmet
    Duman, Cigdem Savas
    Gulpembe, Mustafa
    Acar, Tarik
    Yavuz, Kenan
    Cander, Basar
    Girisgin, Sadik
    Kocak, Sedat
    EURASIAN JOURNAL OF EMERGENCY MEDICINE, 2020, 19 (01) : 40 - 45
  • [4] Optic nerve sheath diameter and intracranial pressure
    Dubourg, Julie
    Javouhey, Etienne
    Messerer, Mahmoud
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2012, 9 (05) : 570 - 571
  • [5] OPTIC NERVE SHEATH DIAMETER TO EVALUATE INCREASED INTRACRANIAL PRESSURE IN HEPATIC ENCEPHALOPATHY
    McLaughlin, Diane
    CRITICAL CARE MEDICINE, 2019, 47
  • [6] Optic Nerve Sheath Diameter Assessment in Patients with Intracranial Pressure Monitoring
    Kavi, Tapan
    Gupta, Anuj
    Hunter, Krystal
    Schreiber, Craig
    Shaikh, Hamza
    Turtz, Alan R.
    CUREUS, 2018, 10 (11):
  • [7] Optic nerve sheath diameter and intracranial pressure RESPONSE
    Driessen, Caroline
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2012, 9 (05) : 571 - 571
  • [8] Correlation of optic nerve and optic nerve sheath diameter with intracranial pressure in pigs
    Mija, R.
    Zubak, I
    Schuetz, A.
    Glas, M.
    Fung, C.
    Jakob, S. M.
    Beck, J.
    Z'Graggen, W. J.
    Bloch, Andreas
    PLOS ONE, 2020, 15 (02):
  • [9] Optic nerve sheath diameter measurement: a means of detecting increased intracranial pressure in pseudotumor cerebri patients
    Ertekin, T.
    Boyaci, M. G.
    Bilir, A.
    Yucel, A.
    Ertekin, A.
    Turamanlar, O.
    Duman, R.
    FOLIA MORPHOLOGICA, 2022, 81 (03) : 567 - 573
  • [10] Optic Nerve Sheath Diameter Evaluation With Two Ultrasound Techniques in Patients at Risk for Increased Intracranial Pressure
    Vitiello, Livio
    De Bernardo, Maddalena
    Rosa, Nicola
    CRITICAL CARE MEDICINE, 2019, 47 (09) : E787 - E787