摘要
The Macintosh laryngoscope blade was compared with three modified blades-the Bizzarri-Giuffrida, the 'Improved Vision' Macintosh, and the Wiemers blade. Before and after a training session 24 participants intubated a Laerdal Airway Management Trainer with the four blades in random order. Intubation time was measured, oesophageal malpositions and 'clicks' indicating possible teeth damage, were counted. Each participant scored the handling of each blade on a 6-point scale (1 = very good, 6 = very poor). Intubation times before training were 10.6 +/- 5.3 s for the Macintosh, 16.7 +/- 9.2 a for the Bizzarri-Giuffrida, 13.3 +/- 9.0 s for the 'Improved Vision' Macintosh and 11.7 +/- 6.1 s for the Wiemers. Intubation times after training were 7.1 +/- 2.5 s for the Macintosh, 10.6 +/- 5.4 s for the Bizzarri-Giuffrida, 8.1 +/- 3.4 s for the 'Improved Vision' Macintosh and 7.6 +/- 2.5 s for the Wiemers. The handling scores were: 2.0 +/- 0.8 for the Macintosh, 3.9 +/- 1.2 for the Bizzarri-Giuffrida, 2.1 +/- 0.8 for the 'Improved Vision' and 2.3 +/- 0.8 for the Wiemers. In regard to the intubation time before training (P < 0.02), the intubation time after training (P < 0.003), and handling (P < 0.0005), the Bizzarri-Giuffrida was significantly inferior to the Macintosh. The 'Improved Vision' Macintosh and the Wiemers were not significantly different to the Macintosh. No significant difference was seen for oesophageal malpositioning and 'clicks' between any of the blades. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:241 / 245
页数:5
相关论文
共 50 条
  • [21] Comparing the Intubation Performance of Macintosh and Airtraq Laryngoscopes
    Sun, Chao
    Xue, Fu-Shan
    Liu, Gao-Pu
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2017, 29 (01) : 69 - 70
  • [22] PROTOTYPE MACINTOSH LARYNGOSCOPES AND THE REAL-MCCOY
    UNCLES, DR
    CARAPIET, DA
    KAPILA, A
    SALT, RH
    ANAESTHESIA, 1995, 50 (02) : 175 - 176
  • [23] Comparison of the Bullard and Macintosh laryngoscopes for endotracheal intubation of patients with a potential cervical spine injury
    Watts, ADJ
    Gelb, AW
    Bach, DB
    Pelz, DM
    ANESTHESIOLOGY, 1997, 87 (06) : 1335 - 1342
  • [24] The effect of steam sterilisation on fibrelight Macintosh laryngoscopes
    Thompson, C
    ANAESTHESIA, 2000, 55 (02) : 185 - 186
  • [25] Comparing performance of Macintosh and Intubrite laryngoscopes for intubation
    Jin, Jin-Hua
    Xue, Fu-Shan
    Li, Hui-Xian
    Liu, Ya-Yang
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (06): : 924 - 925
  • [26] Further development of laryngoscopes for anaesthesia - the Macintosh blade
    Ball, C. M.
    Westhorpe, R. N.
    ANAESTHESIA AND INTENSIVE CARE, 2015, 43 (02) : 147 - 148
  • [27] Comparison of Macintosh and Intubrite laryngoscopes for intubation performed by novice physicians in a difficult airway scenario
    Szarpak, Lukasz
    Smereka, Jacek
    Ladny, Jerzy R.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (05): : 796 - 797
  • [28] A comparison of McCoy, TruView, and Macintosh laryngoscopes for tracheal intubation in patients with immobilized cervical spine
    Bharti, Neerja
    Arora, Suman
    Panda, Nidhi B.
    SAUDI JOURNAL OF ANAESTHESIA, 2014, 8 (02) : 188 - 192
  • [29] A Comparison of Miller Straight Blade and Macintosh Blade Laryngoscopes for Intubation in Morbidly Obese Patients
    Ratajczyk, Pawel
    Kluj, Przemyslaw
    Szmyd, Bartosz
    Resch, Julia
    Hogendorf, Piotr
    Durczynski, Adam
    Gaszynski, Tomasz
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (03)
  • [30] Comparison of the macintosh, mccoy, airtraq® laryngoscopes and intubating lma in a simulated difficult airway with manual in-line stabilisation - a randomised crossover simulation study
    Sherren, Peter
    Kong, Ming-Li
    Chang, Serene
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 : 119 - 119