A randomised comparison of three laryngoscopes with the Macintosh

被引:5
|
作者
Maleck, WH [1 ]
Koetter, KP [1 ]
Lenz, M [1 ]
Piper, SN [1 ]
Triem, J [1 ]
Boldt, J [1 ]
机构
[1] Anaesthesiol Klinikum, D-67063 Ludwigshafen, Germany
关键词
airway management; training; laryngoscopy; manikin; tracheal intubation; orotracheal intubation;
D O I
10.1016/S0300-9572(99)00094-5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The Macintosh laryngoscope blade was compared with three modified blades-the Bizzarri-Giuffrida, the 'Improved Vision' Macintosh, and the Wiemers blade. Before and after a training session 24 participants intubated a Laerdal Airway Management Trainer with the four blades in random order. Intubation time was measured, oesophageal malpositions and 'clicks' indicating possible teeth damage, were counted. Each participant scored the handling of each blade on a 6-point scale (1 = very good, 6 = very poor). Intubation times before training were 10.6 +/- 5.3 s for the Macintosh, 16.7 +/- 9.2 a for the Bizzarri-Giuffrida, 13.3 +/- 9.0 s for the 'Improved Vision' Macintosh and 11.7 +/- 6.1 s for the Wiemers. Intubation times after training were 7.1 +/- 2.5 s for the Macintosh, 10.6 +/- 5.4 s for the Bizzarri-Giuffrida, 8.1 +/- 3.4 s for the 'Improved Vision' Macintosh and 7.6 +/- 2.5 s for the Wiemers. The handling scores were: 2.0 +/- 0.8 for the Macintosh, 3.9 +/- 1.2 for the Bizzarri-Giuffrida, 2.1 +/- 0.8 for the 'Improved Vision' and 2.3 +/- 0.8 for the Wiemers. In regard to the intubation time before training (P < 0.02), the intubation time after training (P < 0.003), and handling (P < 0.0005), the Bizzarri-Giuffrida was significantly inferior to the Macintosh. The 'Improved Vision' Macintosh and the Wiemers were not significantly different to the Macintosh. No significant difference was seen for oesophageal malpositioning and 'clicks' between any of the blades. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:241 / 245
页数:5
相关论文
共 50 条
  • [1] Easy and difficult nasal intubation - a randomised comparison of Macintosh vs Airtraq® laryngoscopes
    St Mont, G.
    Biesler, I.
    Pfoertner, R.
    Mohr, C.
    Groeben, H.
    ANAESTHESIA, 2012, 67 (02) : 132 - 138
  • [2] Comparison of Macintosh and Miller laryngoscopes during pediatric resuscitation
    Brodecki, Marcin
    Sosnowski, Andrzej
    Madziala, Marcin
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (06): : 1098 - 1099
  • [3] Comparison of the Intubrite and Macintosh laryngoscopes in a difficult airway scenario
    Smereka, Jacek
    Ladny, Jerzy R.
    Szarpak, Lukasz
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (06): : 925 - 925
  • [4] Comparison of the Macintosh and Airtraq Laryngoscopes in Endotracheal Intubation Success
    Erturk, Tuna
    Deniz, Suleyman
    Simsek, Fatih
    Purtuloglu, Tarik
    Kurt, Ercan
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2015, 43 (03) : 181 - 187
  • [5] COMPARISON OF HEMODYNAMIC RESPONSE TO TRACHEAL INTUBATION WITH MACINTOSH AND MCCOY LARYNGOSCOPES
    Jitendra, Mukta
    Sharma, Sonal
    Katoch, Madan
    Gulati, Smriti
    Gupta, Heena
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (50): : 8676 - 8684
  • [6] A comparison of McGrath and Macintosh laryngoscopes in novice users: a manikin study
    Ray, D. C.
    Billington, C.
    Kearns, P. K.
    Kirkbride, R.
    Mackintosh, K.
    Reeve, C. S.
    Robinson, N.
    Stewart, C. J.
    Trudeau, T.
    ANAESTHESIA, 2009, 64 (11) : 1207 - 1210
  • [7] A comparison of GlideScope and Macintosh laryngoscopes for endotracheal intubation performed by nurses
    Aleksandrowicz, Sebastian
    Szarpak, Lukasz
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (10): : 2041 - 2041
  • [8] Comparison of the Glidescope®, the McGrath®, the Airtraq® and the Macintosh laryngoscopes in simulated difficult airways
    Savoldelli, G. L.
    Schiffer, E.
    Abegg, C.
    Baeriswyl, V.
    Clergue, F.
    Waeber, J. L.
    ANAESTHESIA, 2008, 63 (12) : 1358 - 1364
  • [9] A clinical comparison of the Flexiblade™ and macintosh laryngoscopes for laryngeal exposure in anesthetized adults
    Cheung, RWW
    Irwin, MG
    Law, BCW
    Chan, CK
    ANESTHESIA AND ANALGESIA, 2006, 102 (02): : 626 - 630
  • [10] A comparison of the forces applied to a manikin during laryngoscopy with the GlideScope® and Macintosh laryngoscopes
    Russell, T.
    Lee, C.
    Firat, M.
    Cooper, R. M.
    ANAESTHESIA AND INTENSIVE CARE, 2011, 39 (06) : 1098 - 1102